McKesson 5059

McKesson Quintet AC Blood Glucose Test Strips Instruction Manual

Model: 5059

1. Koniecview of McKesson Quintet AC Blood Glucose Test Strips

The McKesson Quintet AC Blood Glucose Test Strips are designed for use with the QUINTET AC Blood Glucose Monitoring System and QUINTET AC Blood Glucose Control Solution (sold separately). These strips are intended for measuring glucose levels in fresh capillary whole blood samples.

They are suitable for self-testing at home and for multiple-patient use in professional healthcare settings, such as long-term care facilities and medical offices. The strips feature auto-coding for quick and accurate testing and a unique glove-grip paddle for user convenience. They are for single-use only.

McKesson Quintet AC Blood Glucose Test Strips box and vial

Image: The McKesson Quintet AC Blood Glucose Test Strips packaging, showing the box and a vial of strips.

2. Ważne informacje dotyczące bezpieczeństwa

Te paski testowe służą do in vitro diagnostic use only. Do not use if the expiration date has passed. Do not transfer strips from one vial to another. Never reuse strips. Keep the test strips in their original vial with the cap tightly sealed. This product is not made with natural rubber latex.

Always consult the full QUINTET AC Blood Glucose Monitoring System Owner's Manual for complete safety information and instructions.

3. Konfiguracja

Before performing a test, ensure you have the McKesson Quintet AC Blood Glucose Monitoring System and, if needed, the McKesson Quintet AC Blood Glucose Control Solution. Follow these steps to prepare your test strips:

  1. Ensure your hands are clean and dry before handling the test strips.
  2. Remove one test strip from the vial immediately before use.
  3. Immediately recap the vial tightly after removing a strip to protect the remaining strips from moisture.
  4. Insert the test strip into the blood glucose meter as directed by your meter's instruction manual. The meter will automatically code for accurate testing.
Close-up of a single McKesson Quintet AC Blood Glucose Test Strip

Obraz: Zbliżenie view of a single McKesson Quintet AC Blood Glucose Test Strip, highlighting its design.

McKesson Quintet AC Blood Glucose Test Strips vial

Image: A McKesson Quintet AC Blood Glucose Test Strips vial with its cap, showing the label and contents.

4. Instrukcja obsługi

Once the test strip is inserted into the meter, you are ready to apply a blood sample. Blood can be drawn from the fingertip, palm, or forearm.

  1. Prepare the lancing device and obtain a blood sample as instructed in your blood glucose meter's manual.
  2. Przyłóż końcówkę paska testowego do krwiample. The strip will draw the blood into the reaction area.
  3. Wait for the meter to display the result. The auto-coding feature ensures the meter is correctly calibrated for the strips.
  4. Record your result if necessary and dispose of the used test strip properly.
Hand holding a McKesson Quintet AC Blood Glucose Test Strip with a blood sample

Image: A hand holding a McKesson Quintet AC Blood Glucose Test Strip, with a small blood sample visible on the strip's tip.

Hand inserting a McKesson Quintet AC Blood Glucose Test Strip into a meter

Image: A hand carefully inserting a McKesson Quintet AC Blood Glucose Test Strip into a blood glucose meter.

5. Konserwacja i przechowywanie

Proper maintenance and storage of your test strips are crucial for accurate results and product longevity:

  • Always store test strips in their original vial with the cap tightly sealed.
  • Do not store strips outside of the vial.
  • Store between temperatures 39-86°F (4-30°C).
  • Do NIE freeze the test strips.
  • Use strips within 3 months of opening the vial. Discard any remaining strips after this period.
  • Dispose of used test strips and lancets according to local regulations for biohazardous waste.
McKesson Quintet AC Blood Glucose Test Strips box and two vials on a white surface

Image: The McKesson Quintet AC Blood Glucose Test Strips box and two vials displayed neatly on a white surface.

6. Rozwiązywanie Problemów

The McKesson Quintet AC Blood Glucose Test Strips are designed for reliable performance. If you encounter issues during testing, consider the following general points:

  • Komunikaty o błędach: Refer to your McKesson Quintet AC Blood Glucose Meter's Owner's Manual for specific error codes and their solutions.
  • Nieprawidłowe wyniki: Ensure the test strip vial cap was tightly sealed after the last use. Check the expiration date on the vial. Verify that the blood sample size was adequate.
  • Strip Not Recognized: Ensure the test strip is inserted correctly into the meter. Check for any damage to the strip.

For detailed troubleshooting, always refer to the comprehensive guide provided with your McKesson Quintet AC Blood Glucose Monitoring System.

7. Specyfikacje

FunkcjaSzczegół
Wymiary produktu1.4 x 3.2 x 4.8 cala
Waga przedmiotu4.5 uncji
ProducentMcKesson Brand
Numer modelu przedmiotu5059
Liczba sztuk100 (50 strips per pack, 2 packs)
Funkcja specjalnaDokładny
Typ testuPoziom glukozy we krwi
Konkretne zastosowania produktuBlood, Blood Glucose Test, Glucose Test
Pierwsza dostępna data4 kwietnia 2022 r.

8. Gwarancja i wsparcie

For any general questions regarding McKesson products, please call 1-800-777-4908.

For technical support related to the McKesson Quintet AC Blood Glucose Test Strips or the associated monitoring system, please call 1-888-481-8485.

Please note that specific warranty information for the test strips is typically provided with the McKesson Quintet AC Blood Glucose Monitoring System. Refer to your meter's manual for full warranty details.

© 2024 McKesson. All rights reserved.