HNZXIB SS-90G

HNZXIB Closed Loop Extractor SS-90G Instruction Manual

Model: SS-90G | Brand: HNZXIB

Wstęp

This manual provides detailed instructions for the safe and efficient operation, maintenance, and troubleshooting of your HNZXIB Closed Loop Extractor SS-90G. This 1.5-inch double-layer stainless steel vacuum chamber/tube with a 90-gram capacity and tripod is designed for plant material extraction. Please read this manual thoroughly before use to ensure proper function and longevity of the equipment.

Produkt ponadview

The HNZXIB Closed Loop Extractor SS-90G is a robust system constructed from 304 food-grade stainless steel, ensuring durability and preventing contamination of raw materials. Key features include:

  • Wystarczająca pojemność: 90g capacity (volume after compressing the material) double-layer stainless steel tube. Hot and cold reactants can be added to the outer layer.
  • Ulepszona konfiguracja: Features a food-grade stainless steel ball valve for enhanced robustness and pressure resistance. An additional vacuum gauge allows for convenient observation of reaction vacuum levels. The upgraded detachable tripod bracket offers flexible fixing methods.
  • Dodatkowe akcesoria: Includes 2x 150 micron filters, 3x gaskets, 1x sealing tape, and 1x silicone pad.
  • Tworzywo: Made from 304 food-grade stainless steel, easy to clean and maintain.
HNZXIB Closed Loop Extractor SS-90G with components laid out

Image: HNZXIB Closed Loop Extractor SS-90G components displayed. This image shows the main extractor tube, valves, pressure gauge, clamps, and tripod legs, along with gaskets, filters, sealing tape, and a silicone pad.

Instrukcje konfiguracji

Follow these steps to assemble your HNZXIB Closed Loop Extractor SS-90G. Ensure all components are clean and free from debris before assembly.

  1. Przygotuj komponenty: Lay out all parts, including the main tube, valves, pressure gauge, clamps, tripod legs, gaskets, and sealing tape.
  2. Assemble Valves and Gauge: Attach the ball valves and vacuum gauge to their respective tri-clamp fittings. Ensure gaskets are properly seated for a tight seal.
  3. Attach Tripod Legs: Securely attach the three tripod legs to the bottom tri-clamp fitting using the provided clamps and tools. Ensure the legs are evenly spaced for stability.
  4. Connect Top Assembly: Place a gasket on the top flange of the main tube. Carefully align and attach the top assembly (with valve and pressure gauge) to the main tube using a tri-clamp. Dokręć zaciskamp bezpiecznie.
  5. Connect Bottom Assembly: Place a gasket on the bottom flange of the main tube. Carefully align and attach the bottom assembly (with valve and tripod legs) to the main tube using a tri-clamp. Dokręć zaciskamp bezpiecznie.
  6. Kontrola końcowa: Verify all connections are tight and secure. Ensure the tripod provides a stable base for the extractor.

Video: Closed Loop Extractor Installation Guide (Duration: 5:35). This video demonstrates the step-by-step assembly process for the HNZXIB Closed Loop Extractor, including attaching valves, the pressure gauge, and the tripod legs to the main chamber.

HNZXIB Closed Loop Extractor SS-90G parts display

Obraz: Szczegółowy view of HNZXIB Closed Loop Extractor SS-90G components, including the main tube, valves, pressure gauge, clamps, and tripod legs, along with gaskets, filters, sealing tape, and a silicone pad.

Instrukcja obsługi

Operating a closed-loop extractor requires careful attention to safety and procedure. This section provides general guidance. Always refer to specific solvent handling guidelines and local regulations.

  1. Materiał załadunkowy: Ensure the material to be extracted is properly prepared and loaded into the extraction column.
  2. Connect Solvent Tank: Connect the solvent tank to the appropriate inlet on the extractor.
  3. Vacuum and Pressure Check: Use the vacuum gauge to ensure the system is sealed and can hold a vacuum. This is crucial for safe operation.
  4. Solvent Introduction: Slowly introduce the solvent into the extraction column. Monitor pressure and flow.
  5. Proces ekstrakcji: Allow sufficient time for the solvent to interact with the material.
  6. Kolekcja: Open the appropriate valves to collect the extracted solution into a recovery tank.
  7. Solvent Recovery: Initiate the solvent recovery process, typically involving heating the collection vessel and condensing the solvent back into the solvent tank.
  8. Product Retrieval: Once solvent recovery is complete, safely open the system to retrieve the extracted product.

Ważna uwaga dotycząca bezpieczeństwa: Operating closed-loop extraction systems involves handling flammable and pressurized materials. Always operate in a well-ventilated area, wear appropriate personal protective equipment (PPE), and ensure all connections are leak-free. Consult with experienced professionals and adhere to all safety protocols and local regulations.

Assembled HNZXIB Closed Loop Extractor SS-90G

Image: Fully assembled HNZXIB Closed Loop Extractor SS-90G, ready for operation.

Konserwacja

Regular maintenance ensures the longevity and safe operation of your HNZXIB Closed Loop Extractor SS-90G.

  • Czyszczenie: After each use, thoroughly clean all components with appropriate cleaning agents to remove any residual material or solvent. Ensure all parts are dry before reassembly or storage.
  • Kontrola uszczelki: Regularly inspect all gaskets for signs of wear, cracking, or damage. Replace worn gaskets immediately to maintain a proper seal and prevent leaks.
  • Kontrola zaworu: Periodically check the ball valves for smooth operation and ensure they open and close completely.
  • Kalibracja manometru: If accuracy is critical, consider periodic calibration of the vacuum gauge.
  • Składowanie: Store the extractor in a clean, dry environment when not in use.

Rozwiązywanie problemów

This section addresses common issues you might encounter with your closed-loop extractor.

ProblemMożliwa przyczynaRozwiązanie
Loss of Vacuum/Pressure
  • Uszkodzone lub nieprawidłowo osadzone uszczelki.
  • luźne clamps.
  • Wadliwy zawór.
  • Inspect and replace all gaskets.
  • Tighten all tri-clampjest bezpiecznie.
  • Check valve operation; replace if necessary.
Slow Extraction Rate
  • Zatkany filtr.
  • Insufficient solvent flow.
  • Material packed too tightly.
  • Wymień lub wyczyść filtr.
  • Ensure solvent tank has adequate pressure/flow.
  • Repack material less densely.
Product Contamination
  • Improper cleaning.
  • Uszkodzone podzespoły.
  • Non-food grade materials used.
  • Thoroughly clean all parts before use.
  • Inspect for damage; replace components as needed.
  • Ensure only specified food-grade materials are used.

If you encounter issues not listed here or require further assistance, please contact HNZXIB customer support.

Specyfikacje

FunkcjaSzczegół
Wymiary produktu13.4 x 15.7 x 26.8 cala
Waga przedmiotu9.72 funta
ProducentHNZXIB
ASINB09FSVBTYS
Numer modelu przedmiotuHNZXIB003
Data pierwszej dostępności21 października 2021 r.
Pojemność90g (after compressing material)
TworzywoStal nierdzewna 304 do kontaktu z żywnością
HNZXIB Closed Loop Extractor SS-90G dimensions

Image: HNZXIB Closed Loop Extractor SS-90G with key dimensions labeled.

Gwarancja i wsparcie

The HNZXIB Closed Loop Extractor SS-90G comes with a 1-letnia gwarancja. This warranty covers manufacturing defects and malfunctions under normal use conditions. Please note that gaskets, filters, and other consumable accessories are excluded from this warranty.

For any product issues or support inquiries, please contact HNZXIB customer service. We are committed to resolving any problems you may encounter.

Manufacturer: HNZXIB

Seller: Henan Zhuoxian Import & Export Trading Co., Ltd.

© 2026 HNZXIB. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.