1. Wprowadzenie
The BENNING CM 2-1 is a True RMS current clamp multimeter designed for precise electrical measurements in various applications. This device offers accurate current measurement up to 400 A AC/DC and voltage measurement up to 600 V AC/DC. Key features include an AutoV function with low input impedance (LoZ) to suppress reactive voltage and a low pass filter (HFR high frequency suppression) for measurements on clocked motor drives. It is rated for measurement categories CAT IV 300 V and CAT III 600 V, ensuring safety and reliability.
2. Informacje dotyczące bezpieczeństwa
WARNING: Read and understand all safety information and operating instructions before using this instrument. Failure to follow these instructions could result in severe injury or death.
- Always adhere to local and national safety regulations.
- Nie używaj multimetru, jeśli wygląda na uszkodzony lub jeśli izolacja przewodów pomiarowych jest naruszona.
- Przed dokonaniem jakichkolwiek pomiarów należy upewnić się, że wybrano właściwą funkcję i zakres.
- Nie należy przekraczać maksymalnych limitów wejściowych dla żadnej funkcji.
- Zachowaj ostrożność podczas pracy z wolumenemtages above 30 V AC RMS, 42 V AC peak, or 60 V DC, as these pose a shock hazard.
- Always disconnect the test leads from the circuit before changing the function switch.
- Aby zapewnić dokładne odczyty, należy wymienić baterie, gdy pojawi się wskaźnik niskiego poziomu naładowania baterii.
- The device is rated CAT IV 300 V and CAT III 600 V. Understand these categories and use the meter only in appropriate environments.
3. Zawartość opakowania
Sprawdź, czy po rozpakowaniu wszystkie elementy są obecne i nieuszkodzone:
- BENNING CM 2-1 True RMS Current Clamp Multimetr
- Protective carrying bag
- Zestaw przewodów pomiarowych (czerwony i czarny)
- 2 AAA batteries (pre-installed or included separately)

Image 3.1: The BENNING CM 2-1 multimeter shown with its protective carrying bag and test leads.
4. Koniec produktuview
The BENNING CM 2-1 features a compact design with a clear digital display, a rotary function switch, and control buttons for various measurement modes.
4.1. Sterowanie i wyświetlacz
- Clamp Szczęka: Do bezkontaktowego pomiaru prądu AC/DC.
- Przełącznik obrotowy: Selects measurement functions (OFF, LoZ, AutoV, V~, V-, Hz, Ω, A~, A-).
- HOLD/MIN MAX Button: Freezes the current reading or displays minimum/maximum values.
- AC/DC HFR/ZERO Button: Toggles between AC/DC current, activates the low pass filter (HFR), or zeros the DC current reading.
- Wyświetlacz: Digital readout for measurement values, units, and indicators.
- Input Jacks (COM, VΩ): Do podłączania przewodów pomiarowych do pomiaru objętościtage, rezystancja i inne pomiary.
5. Konfiguracja
5.1. Instalacja baterii
The BENNING CM 2-1 requires 2 AAA batteries. These are typically included with the device.
- Upewnij się, że multimetr jest wyłączony.
- Znajdź komorę baterii z tyłu urządzenia.
- Za pomocą śrubokręta otwórz pokrywę komory baterii.
- Włóż 2 baterie AAA, zwracając uwagę na prawidłową biegunowość (+/-), zgodnie ze wskazaniami wewnątrz komory.
- Załóż pokrywę komory baterii i zabezpiecz ją śrubą.
6. Instrukcja obsługi
6.1. Pomiar prądu przemiennego/stałego (Clamp)
To measure AC or DC current without breaking the circuit:
- Turn the rotary switch to the “A~” or “A-” position.
- Press the AC/DC HFR/ZERO button to select AC or DC current if necessary. For DC current, press and hold to zero the display before measurement.
- Otwórz klamp jaw and enclose a single conductor. Ensure the jaw is fully closed.
- Odczytaj aktualną wartość na wyświetlaczu.

Image 6.1: The multimeter measuring current by clamping around a single conductor in an electrical panel.

Image 6.2: A close-up of the BENNING CM 2-1 displaying a current measurement of 10.07 A.
6.2. AC/DC Objętośćtage Pomiar
Do pomiaru AC lub DC voltage:
- Insert the red test lead into the VΩ jack and the black test lead into the COM jack.
- Turn the rotary switch to the “V~” for AC voltage or “V-” for DC voltage.
- Podłącz sondy pomiarowe do obwodu lub elementu, który chcesz zmierzyć.
- Przeczytaj tomtage wartość na wyświetlaczu.

Image 6.3: The multimeter measuring voltage using test leads connected to terminals within an electrical cabinet.

Image 6.4: A close-up of the BENNING CM 2-1 displaying a voltage measurement of 124.00 V.
6.3. AutoV Function (LoZ)
The AutoV function with low input impedance (LoZ) helps to suppress 'ghost voltages' or 'reactive voltages' that can appear on unused wires or open circuits due to capacitive coupling. To use:
- Insert the red test lead into the VΩ jack and the black test lead into the COM jack.
- Turn the rotary switch to the “LoZ” position. The meter will automatically detect AC or DC voltage.
- Connect the test probes across the circuit.
- Przeczytaj tomtage wartość na wyświetlaczu.
6.4. Low Pass Filter (HFR)
The HFR (High Frequency Rejection) low pass filter is used for stable and accurate measurements on variable frequency drives (VFDs) or other noisy electrical environments. To activate:
- Select the desired AC current (A~) or AC voltage (V~) function.
- Press and hold the AC/DC HFR/ZERO button until “HFR” appears on the display.
- Proceed with your measurement as usual. The filter will suppress high-frequency noise components.
7. Konserwacja
7.1. Czyszczenie
Wyczyść obudowę za pomocą reklamyamp Ściereczką i łagodnym detergentem. Nie używaj środków ściernych ani rozpuszczalników. Przed użyciem upewnij się, że urządzenie jest całkowicie suche.
7.2. Wymiana baterii
When the low battery indicator appears on the display, replace the batteries promptly to ensure continued accurate operation. Refer to Section 5.1 for battery installation instructions.
8. Rozwiązywanie Problemów
- Brak wyświetlacza: Sprawdź instalację i ładowanie baterii. W razie potrzeby wymień baterie.
- Nieprawidłowe odczyty: Ensure correct function and range are selected. Check test lead connections. Verify the clamp jaw is fully closed for current measurements.
- “OL” on Display: Indicates an overload (measurement exceeds the selected range). Select a higher range or ensure the input is within the device's specifications.
- Niestabilne odczyty: Ensure good contact with test probes. For current measurements, ensure only one conductor is within the clamp jaw. Consider using the HFR function in noisy environments.
9. Specyfikacje
| Specyfikacja | Wartość |
|---|---|
| Producent | BENNINGA |
| Numer modelu | 044689 |
| Waga przedmiotu | 480 gramów |
| Wymiary produktu (dł. x szer. x wys.) | Wymiary 17 x 5 x 13 cm |
| Baterie | 2 baterie AAA (w zestawie) |
| Typ ogniwa baterii | Alkaliczny |
| Kolor | Czerwony |
| Styl | Cyfrowy |
| Typ źródła zasilania | Zasilany bateryjnie |
| Typ pomiaru | Multimeter (True RMS) |
| Max. AC/DC Current | 400 A |
| Max. AC/DC Voltage | 600 V |
| Kategoria pomiaru | KAT IV 300 V, KAT III 600 V |
| Norma bezpieczeństwa | PN-EN 61010-1 |
| Zawarte komponenty | Benning CM 2-1, bag, test leads, batteries |
10. Gwarancja i wsparcie
BENNING products are manufactured to high-quality standards. For specific warranty information, please refer to the documentation provided with your purchase or visit the official BENNING website. For technical support, service, or inquiries, please contact your local BENNING distributor or customer service department.