BOJACK BJ-YJF-6158

BOJACK Bathroom Vent Exhaust Fan Motor Replacement Kit (Model BJ-YJF-6158) User Manual

1. Wprowadzenie

This manual provides essential information for the safe and effective installation, operation, and maintenance of your BOJACK Bathroom Vent Exhaust Fan Motor Replacement Kit, model BJ-YJF-6158. This kit is designed to replace existing bathroom exhaust fan motors in various units, including those compatible with Nutone, Broan, Uppco, Ventorola E498-1, Bay Motors, Sears 569, and Dayton models. Please read this manual thoroughly before beginning installation.

2. Informacje dotyczące bezpieczeństwa

OSTRZEŻENIE: Risk of electric shock. Always disconnect power at the circuit breaker or fuse box before installing, servicing, or cleaning the fan motor. Failure to do so can result in serious injury or death.

  • Ensure the power supply matches the motor's specifications (120V, 60Hz).
  • Całe okablowanie musi być zgodne z lokalnymi przepisami i normami elektrycznymi.
  • Jeśli nie masz pewności co do sposobu okablowania, skonsultuj się z wykwalifikowanym elektrykiem.
  • Podczas montażu należy nosić odpowiedni sprzęt ochrony osobistej, taki jak rękawice i okulary ochronne.
  • Podczas pracy należy trzymać ręce i luźne ubrania z dala od ruchomych części.

3. Zawartość opakowania

Przed przystąpieniem do instalacji sprawdź, czy wszystkie komponenty są obecne i nieuszkodzone.

  • 1 x BOJACK Replacement Fan Motor (Model BJ-YJF-6158)
  • 1 x Fan Blade (4.5 inch, flat/paddle style)
BOJACK BJ-YJF-6158 Replacement Fan Motor

Image 3.1: BOJACK BJ-YJF-6158 Replacement Fan Motor. This image shows the motor unit with its electrical wiring and two-prong plug.

4.5 inch Flat/Paddle Style Fan Blade

Image 3.2: 4.5 inch Flat/Paddle Style Fan Blade. This image displays the white plastic fan blade included in the kit.

4. Specyfikacje

FunkcjaSpecyfikacja
Numer modeluBJ-YJF-6158
MarkaBOJACK
Przepływ powietrza (CFM)50 stopy sześcienne na minutę
Tomtage120 wolty
Częstotliwość60 Hz
Aktualny0.65 Amps
Prędkość3000 obr./min.
Moc78 watów
Długość wału1.75 cali
Średnica wału3/16 cala (0.19 cala)
Długość przewodu6 inches (with 2-prong plug)
Kołki montażowe1-7/8 inches on center
Średnica łopatki wentylatora4.5 cali
CertyfikatyCertyfikat UL
Technical Specification Diagram for BOJACK BJ-YJF-6158 Motor

Image 4.1: Technical Specification Diagram. This diagram illustrates the dimensions and electrical specifications of the motor and fan blade.

Fan Blade Dimensions

Image 4.2: Fan Blade Dimensions. This image shows the diameter (113 mm / 4.45 inches) and height (25.4 mm / 1 inch) of the fan blade.

5. Instrukcje instalacji

Follow these steps carefully to install your new exhaust fan motor.

  1. Odłącz zasilanie: Locate the circuit breaker for your bathroom exhaust fan and turn off the power. Verify that the power is off using a voltagtester.
  2. Zdejmij osłonę wentylatora: Carefully remove the existing fan cover, usually by pulling down or unlatching clips.
  3. Remove Old Motor Assembly: Disconnect the old motor's power plug from the receptacle. Unfasten any screws or clips holding the old motor and fan blade assembly in place. Gently remove the old unit.
  4. Assemble New Motor and Fan Blade: The new motor and fan blade are supplied separately. Slide the new fan blade onto the motor shaft. Ensure it is securely seated.
  5. Check Fan Blade Orientation (Important): Some users have reported that the fan blade may need to be reversed for correct airflow. Before final installation, temporarily connect the motor to power (briefly, with extreme caution and ensuring no contact with moving parts) to observe the direction of rotation and airflow. If the airflow is incorrect (e.g., blowing air down instead of exhausting it up), disconnect power, remove the two screws holding the motor's shaft assembly, flip the shaft assembly 180 degrees, and re-secure the screws. Then re-attach the fan blade.
  6. Montaż nowego zespołu silnika: Position the new motor and fan blade assembly into the fan housing. Secure it using the existing mounting studs (1-7/8" on center) or screws.
  7. Podłącz zasilanie: Plug the new motor's 2-prong plug into the receptacle inside the fan housing.
  8. Reattach Fan Cover: Replace the fan cover, ensuring it is securely fastened.
  9. Przywróć zasilanie: Turn the power back on at the circuit breaker. Test the fan for proper operation.
BOJACK BJ-YJF-6158 Motor with Fan Blade Attached

Image 5.1: Assembled Motor and Fan Blade. This image shows the motor with the fan blade correctly attached to the shaft, ready for installation.

6. Instrukcja obsługi

Once installed, the BOJACK BJ-YJF-6158 exhaust fan motor operates automatically when power is supplied to the fan unit, typically via a wall switch. Ensure the fan is switched on when moisture or odors are present in the bathroom to facilitate proper ventilation.

7. Konserwacja

Regular maintenance helps ensure optimal performance and longevity of your exhaust fan motor.

  • Czyszczenie: At least once a year, or more frequently in dusty environments, disconnect power to the fan. Remove the fan cover and gently clean the fan blade and motor housing with a soft cloth or brush to remove dust and debris. Do not use harsh chemicals or immerse the motor in water.
  • Kontrola: Periodically inspect the wiring for any signs of wear or damage. Ensure all connections remain secure.

8. Rozwiązywanie Problemów

If you encounter issues with your fan motor, refer to the following troubleshooting guide:

ProblemMożliwa przyczynaRozwiązanie
Wentylator nie włącza sięBrak zasilania
Luźne połączenie przewodów
Wadliwy silnik
Sprawdź wyłącznik/bezpiecznik. Upewnij się, że przełącznik ścienny jest włączony.
Verify all electrical connections are secure (with power off).
If power is confirmed and connections are secure, the motor may be faulty and require replacement.
Wentylator jest nadmiernie głośnyFan blade unbalanced or hitting housing
Dust/debris on fan blade or motor
Zużyte łożyska silnika
Ensure fan blade is securely attached and not touching housing. Re-seat if necessary.
Clean fan blade and motor thoroughly (with power off).
If noise persists after cleaning and balancing, the motor may need replacement.
Fan runs but airflow is weak or incorrect directionFan blade installed backwards
Obstruction in vent duct
Disconnect power. Refer to Step 5 in Installation Instructions to check and correct fan blade orientation.
Inspect vent duct for blockages.

9. Gwarancja i wsparcie

Specific warranty details for this product are not provided in this manual. For warranty inquiries or technical support, please contact BOJACK customer service through your original point of purchase or refer to the product packaging for contact information.