This manual provides essential information for the safe and efficient operation of the AUTONICS CX6M-2P4 Counter/Timer. The CX6M-2P4 is a versatile 6-digit LCD counter/timer unit, designed for industrial applications requiring precise counting and timing functions. It features 2 preset outputs, supports both PNP and NPN input types, and includes prescale value setting capabilities. The unit offers 2 SPDT (2c) relay outputs and 2 NPN open collector outputs, operating on a 100-240 VAC power supply.

2. Informacje dotyczące bezpieczeństwa

Read and understand all safety precautions before installing or operating the device. Failure to follow these instructions may result in injury or product damage.

  • Bezpieczeństwo elektryczne: Ensure power is disconnected before wiring or performing maintenance. Only qualified personnel should perform electrical work.
  • Warunki środowiskowe: Do not install the unit in locations subject to direct sunlight, high humidity, excessive dust, or corrosive gases.
  • Obsługiwanie: Avoid dropping or subjecting the unit to strong impacts. Do not disassemble or modify the unit.
  • Zasilanie: Użyj podanego zasilacza Voltage (100-240 VAC). Incorrect voltagmoże spowodować uszkodzenie.

3. Koniec produktuview

The AUTONICS CX6M-2P4 is a compact and robust counter/timer designed for precise control in various industrial settings.

3.1. Funkcje

  • W72xH72mm standard panel size.
  • 6-digit LCD display for clear readings.
  • Two independent preset values for flexible control.
  • Supports both PNP and NPN input types.
  • Adjustable prescale value setting.
  • Two SPDT (2c) relay outputs (250VAC 3A).
  • Two NPN open collector outputs.
  • Wide power supply range: 100-240 VAC.

3.2. składniki

The unit consists of a front panel with an LCD display and control buttons, and a rear panel with terminal blocks for power, input, and output connections.

AUTONICS CX6M-2P4 Counter/Timer front view

Image showing the front panel of the AUTONICS CX6M-2P4 Counter/Timer, displaying the 6-digit LCD, control buttons, and overall dimensions.

4. Konfiguracja

4.1. Montaż

The CX6M-2P4 is designed for panel mounting. Cut a rectangular opening of 68x68mm (W x H) in the panel. Insert the unit from the front and secure it using the provided mounting brackets from the rear. Ensure a tight fit to prevent dust and moisture ingress.

4.2. Okablowanie

Before wiring, ensure that the power supply is completely disconnected. Refer to the wiring diagram on the side of the unit or in the full product manual for detailed connections. Below are general guidelines:

  • Zasilanie: Connect the 100-240 VAC power to the designated power terminals.
  • Połączenia wejściowe: Connect the PNP or NPN sensor inputs to the appropriate input terminals. Ensure correct polarity for NPN/PNP sensors.
  • Połączenia wyjściowe: Connect the load to the relay output terminals (SPDT) and/or the NPN open collector output terminals as required by your application.

5. Instrukcja obsługi

5.1. Podstawowa obsługa

Once powered on, the unit will display the current count or time value. The front panel buttons allow for resetting the count, switching display modes, and accessing parameter settings.

  • Przycisk reset: Press to reset the current count or timer value to zero.
  • Przycisk TRYB: Press to cycle through different display modes or enter parameter setting mode.
  • Przyciski GÓRA/DÓŁ: Used to adjust values when in parameter setting mode.

5.2. Ustawianie parametrów

To configure the counter/timer, enter the parameter setting mode:

  1. Press and hold the MODE button for a few seconds until the display changes to the parameter setting menu.
  2. Use the UP/DOWN buttons to navigate through the parameters (e.g., preset values, input mode, prescale value, output mode).
  3. Press the MODE button briefly to select a parameter for editing.
  4. Use the UP/DOWN buttons to change the parameter value.
  5. Press the MODE button again to confirm the new value and move to the next parameter or exit the editing mode.
  6. To exit the parameter setting mode, navigate to the end of the menu or hold the MODE button again.

6. Konserwacja

The AUTONICS CX6M-2P4 is designed for long-term, reliable operation with minimal maintenance. Follow these guidelines to ensure optimal performance:

  • Czyszczenie: Gently wipe the unit's surface with a soft, dry cloth. Do not use abrasive cleaners, solvents, or water directly on the unit.
  • Kontrola: Periodically check wiring connections for looseness or damage. Ensure the unit is free from dust accumulation, especially around ventilation areas.
  • Składowanie: If storing the unit, keep it in a dry, cool place away from direct sunlight and extreme temperatures.

7. Rozwiązywanie Problemów

Aby zapoznać się z częstymi problemami i możliwymi rozwiązaniami, zapoznaj się z poniższą tabelą.

ProblemMożliwa przyczynaRozwiązanie
Urządzenie nie włącza się.Brak zasilania lub nieprawidłowe okablowanie.Sprawdź połączenia zasilania i upewnij się, że napięcie jest prawidłowetagi (100-240 V AC).
Count/Time does not increment.Input sensor not connected, faulty, or incorrect input mode setting.Verify sensor wiring, check sensor functionality, and confirm input mode (PNP/NPN) in settings.
Output does not activate.Preset value not reached, output mode incorrect, or load wiring issue.Check preset values, verify output mode settings, and inspect load wiring.
Wyświetlacz pokazuje kod błędu.Internal error or specific fault condition.Refer to the full product manual for specific error code meanings. Power cycle the unit. If the error persists, contact support.

8. Specyfikacje

Technical specifications for the AUTONICS CX6M-2P4 Counter/Timer.

ParametrWartość
ModelCX6M-2P4
Wyświetlacz6-cyfrowy wyświetlacz LCD
Wymiary (szer. x wys.)72mm x 72mm
Typ wejściaPNP or NPN selectable
Preset Outputs2 (Relay SPDT (2c) 250VAC 3A, NPN Open Collector)
Zasilacz100-240 VAC
Waga1.1 funta (ok. 0.5 kg)

9. Gwarancja i wsparcie

AUTONICS products are manufactured under strict quality control. For warranty information, please refer to the warranty card included with your product or visit the official AUTONICS website. For technical support, service, or inquiries, please contact your local AUTONICS distributor or customer service center. Provide the model number (CX6M-2P4) when seeking assistance.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.