Wstęp
This manual provides instructions for the safe and effective operation of the BST-58F Digital Multimeter. This auto-ranging multimeter is designed for measuring AC/DC voltage, AC/DC current, resistance, capacitance, and frequency, featuring 4000 counts for precise readings. It is suitable for maintenance testing of various electronic products.
Cechy produktu

Opis obrazu: This image displays the BST-58F Digital Multimeter from the front and back, highlighting its general characteristics. The text on the image indicates 'Product Usage' and 'CHARACTERISTICS', stating that the product is used for maintenance testing of various electronic products, features a metal shielding plate, anti-magnetic and anti-interference performance, full protection, anti-high voltage ignition circuit design, and automatic gear position recognition for convenient operation.
- Automatic identification within 3 seconds for simplified operation.
- Data hold function to freeze readings on the display.
- Funkcja automatycznego wyłączania zasilania pozwalająca oszczędzać baterię.
- Niska objętośćtage display indicator.
- Anti-vibration design for durability.
- Streamlined design for comfortable handling.
- Large screen display for clear character visibility.
- Strong anti-interference capability.
- Full protection and anti-high voltage circuit design.
- Self-recovery fuse protection circuit.
- Objętość bezkontaktowatage (NCV) wykrywanie.
- Pomiar rzeczywistej wartości skutecznej (RMS) umożliwiający dokładne odczyty przebiegów niesinusoidalnych.
- Screen backlight for easy reading in low-light conditions.
- Flashlight lighting.
Informacje dotyczące bezpieczeństwa
To ensure safe operation and service of the meter, follow these instructions:
- Przed użyciem miernika należy przeczytać i zrozumieć wszystkie instrukcje oraz informacje dotyczące bezpieczeństwa zawarte w niniejszej instrukcji.
- Nie należy przekraczać maksymalnych wartości wejściowych określonych dla każdego zakresu pomiarowego.
- Zachowaj ostrożność podczas pracy z objętościątagpowyżej 30 V AC RMS, 42 V szczytowo lub 60 V DC. Te wartościtagStwarzają ryzyko porażenia prądem.
- Przed zmianą funkcji lub zakresów należy zawsze odłączyć przewody pomiarowe od obwodu.
- Sprawdź przewody pomiarowe pod kątem uszkodzonej izolacji lub odsłoniętego metalu. Wymień, jeśli są uszkodzone.
- Nie należy używać miernika, jeśli wygląda na uszkodzony lub jeśli jego obudowa jest otwarta.
- Przed użyciem należy sprawdzić, czy pokrywa komory baterii jest szczelnie zamknięta.
- Nie należy używać miernika w wilgotnym otoczeniu ani w obecności wybuchowych gazów lub pyłów.
- Podczas pomiaru prądu należy upewnić się, że miernik jest podłączony szeregowo do obciążenia i obwód jest odłączony od napięcia przed podłączeniem.
Produkt ponadview i komponenty
Familiarize yourself with the components of your BST-58F Digital Multimeter.

Opis obrazu: This image displays the BST-58F Digital Multimeter with various components labeled. Key labels include: LED light, Indicator light, Screen, Model, Case, Data Hold/Backlight button (H/*), NCV/LED button (NCV/B), Power/Capacitance button (O/H), Current Terminal (10A UNFUSED), COM terminal, and Voltage, Resistance, Capacitance, Continuity terminal (VΩ-4-). The screen shows "APO" indicating Auto Power Off.
- Ekran: Wyświetla odczyty pomiarów i wskaźniki.
- Światło LED: Do oświetlenia.
- Kontrolka: Zapewnia wizualną informację zwrotną.
- NCV/LED Button: Aktywuje bezkontaktową głośnośćtage detection and LED light.
- Przycisk H/*: Activates Data Hold and Backlight functions.
- O/H Button: Power On/Off and function selection.
- Current Terminal (10A UNFUSED): Wejście do pomiarów dużego prądu.
- Terminal COM: Wspólny (ujemny) sygnał wejściowy dla wszystkich pomiarów.
- VΩ-4- Terminal: Wejście dla voltage, resistance, capacitance, and continuity measurements.
Organizować coś
Instalacja baterii
The BST-58F multimeter requires 2 x 1.5V AAA batteries for operation. To install or replace batteries:
- Upewnij się, że multimetr jest wyłączony i odłącz wszystkie przewody pomiarowe.
- Znajdź pokrywę komory baterii z tyłu urządzenia.
- Użyj śrubokręta, aby otworzyć komorę baterii.
- Włóż dwie baterie AAA 1.5 V, zwracając uwagę na prawidłową biegunowość (+ i -).
- Załóż pokrywę komory baterii i zabezpiecz ją śrubą.
Podłączanie przewodów testowych
Always connect the black test lead to the COM terminal. Connect the red test lead to the appropriate input terminal based on the measurement type:
- dla objtage, Resistance, Capacitance, and Continuity: Connect the red lead to the VΩ-4- terminal.
- For Current (up to 10A): Connect the red lead to the 10A UNFUSED terminal.
Instrukcja obsługi
Powering On/Off and Automatic Identification

Opis obrazu: This image illustrates the power-on process and automatic measurement function. The left panel shows the multimeter off, with text "1: Long press the yellow button to start the device". The right panel shows the multimeter with test leads connected, indicating "2: Automatic measurement of gear position". The screen displays "APO" and "HOLD" indicators.
- Aby włączyć urządzenie, long press the yellow O/H button. The multimeter will automatically identify the measurement type (voltage, resistance, continuity) within 3 seconds when test leads are connected to a circuit.
- The multimeter features an automatic power-off function to save battery.
Objętość bezkontaktowatage (NCV) Test

Opis obrazu: This image shows the multimeter's NCV (Non-Contact Voltage) test feature. The text "NCV Non-contact Test" is prominent, with an arrow pointing to the NCV sensing area at the top of the device. The screen shows "APO" and the NCV/B button is visible.
To perform a Non-Contact VoltagTest:
- Long press the NCV/B button to enter induction mode.
- Move the NCV sensing area (located at the top of the multimeter) close to the conductor being tested.
- Multimetr wskaże obecność objętości prądu przemiennegotagpoprzez sygnał dźwiękowy i/lub wskaźnik wizualny.
Przytrzymywanie danych i podświetlenie
Naciśnij H/* button briefly to activate the Data Hold function, which freezes the current reading on the display. Press it again to release. Long press the H/* button to turn the screen backlight on or off for improved visibility in dark environments.
General Measurement Principles
The BST-58F automatically identifies the measurement type. Ensure test leads are correctly connected for the desired measurement.
- TomtagPomiar (AC/DC): Connect leads in parallel with the circuit.
- Pomiar prądu (AC/DC): Connect leads in series with the circuit. Ensure the circuit is de-energized before connecting.
- Pomiar rezystancji: Ensure the circuit is de-energized before measuring resistance. Connect leads across the component.
- Pomiar pojemności: Ensure the capacitor is discharged before measuring.
- Pomiar częstotliwości: Connect leads to the signal source.
- Test ciągłości: For checking circuit continuity. An audible beep indicates continuity.

Opis obrazu: This image displays the multimeter and lists its key measurement capabilities: 1KHz True RMS, NCV induced voltage, AC and DC current, AC and DC voltage, Zero fire line identification, and Resistance on and off. It also shows icons for various measurement types like voltage, current, frequency, and diode test, indicating the multimeter's versatility.
Konserwacja
Czyszczenie
Wytrzyj licznik reklamąamp Ściereczką i łagodnym detergentem. Nie używaj środków ściernych ani rozpuszczalników. Utrzymuj zaciski w czystości i bez wilgoci.
Wymiana baterii
When the low battery indicator appears on the display, replace the batteries as described in the "Battery Installation" section under Setup. Remove batteries if the meter is not used for an extended period.
Składowanie
Store the multimeter in a cool, dry place, away from direct sunlight and extreme temperatures. The recommended storage environment is -20°C to 60°C with humidity less than 80%.
Rozwiązywanie problemów
| Problem | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| Miernik się nie włącza. | Rozładowane lub nieprawidłowo zainstalowane baterie. | Sprawdź biegunowość baterii, wymień baterie. |
| Brak odczytu lub wyświetlenie komunikatu „OL”. | Open circuit, out of range, or incorrect function/lead connection. | Check circuit, ensure correct function selected, verify lead connections. |
| Niedokładne odczyty. | Low battery, dirty test leads/terminals, external interference. | Replace batteries, clean leads/terminals, move away from strong electromagnetic fields. |
| Auto power-off too quickly. | Normal operation (default setting). | Engage in a measurement or press a button to reset the timer. |
Specyfikacje
The following tables detail the technical specifications and measurement ranges of the BST-58F Digital Multimeter.

Opis obrazu: This image shows a table of general product parameters for the BST-58F multimeter. It lists: Product number (BST-58F), LCD (4000word), Range (automatic), Material (ABS-PCV), Sampling rate (3 times/sec), True RMS (✓), Data retention (✓), Screen backlight (✓), Flashlight lighting (✓), Low battery prompt (✓), Automatic shut-down (✓). Under "parameter", it lists: product weight (133g), Product Size (126*61*28mm), power supply (1.5V AAA battery*2), working environment (Temperature 0~40°C, Humidity <75%), Storage environment (Temperature -20~60°C, Humidity <80%).
| Parametr | Wartość |
|---|---|
| Numer produktu | BST-58F |
| Wyświetlacz | 4000 Counts LCD |
| Nośny | Automatyczny |
| Tworzywo | ABS-PCV |
| Sampling Oceń | 3 razy/sek. |
| Prawdziwy RMS | Tak |
| Przechowywanie danych | Tak |
| Podświetlenie ekranu | Tak |
| Flesz | Tak |
| Monit o niskim poziomie naładowania baterii | Tak |
| Automatyczne wyłączanie | Tak |
| Waga produktu | 133g |
| Rozmiar produktu | 126x61x28mm |
| Zasilacz | 2 baterie AAA 1.5 V |
| Środowisko pracy | 0~40°C, Humidity <75% |
| Środowisko przechowywania | -20~60°C, Humidity <80% |
Zakresy pomiarowe i dokładność:

Opis obrazu: This image presents a table outlining the functions, ranges, and accuracy of the BST-58F multimeter. It includes specifications for DC voltage (4V/40V/400V/500V, ±(0.5%+3)), AC voltage (4V/40V/400V/500V, ±(1.0%+3)), DC current (999.9mA/9.999A, ±(2.0%+4)), AC current (999.9mA/9.999A, ±(1.0%+3)), Resistance (4Ω/40Ω/400Ω, ±(1.5%+3); 4kΩ/40kΩ/400kΩ, ±(0.5%+3); 4MΩ/40MΩ, ±(1.5%+3)), Capacitance (20nF/200nF, ±(10%+40); 2uF/20uF/200uF, ±(2.5%+20); 2000uF, ±(5%+10)). It also indicates "On and off" and "NCV detection" with checkmarks. The frequency response in AC mode is 40Hz~1kHz.
| Funkcjonować | Zakres | Dokładność |
|---|---|---|
| Objętość DCtage | 4V/40V/400V/500V | ± (0.5%+3) |
| AC Objętośćtage | 4V/40V/400V/500V | ± (1.0%+3) |
| Prąd stały | 999.9mA/9.999A | ± (2.0%+4) |
| Prąd zmienny | 999.9mA/9.999A | ± (1.0%+3) |
| Opór | 4Ω/40Ω/400Ω | ± (1.5%+3) |
| 4kΩ/40kΩ/400kΩ | ± (0.5%+3) | |
| 4MΩ/40MΩ | ± (1.5%+3) | |
| Pojemność | 20nF/200nF | ± (10%+40) |
| 2uF/20uF/200uF | ± (2.5%+20) | |
| 2000 XNUMXuF | ± (5%+10) | |
| Włączanie i wyłączanie (ciągłość) | Tak | — |
| Wykrywanie NCV | Tak | — |
| Frequency response in AC mode: 40Hz~1kHz | ||
Gwarancja i wsparcie
Specific warranty information for this product is not provided in the available documentation. For warranty claims or technical support, please refer to the retailer or manufacturer's contact information provided at the point of purchase.