Itron YES030151

Instrukcja obsługi wyłącznika selektywnego Itron EDF 60A 230V

Model: YES030151

Wstęp

This manual provides essential information for the safe and effective installation, operation, and maintenance of your Itron EDF 60A 230V Selective Circuit Breaker. Please read this manual thoroughly before use and retain it for future reference.

The Itron EDF 60A 230V Selective Circuit Breaker is designed to protect your electrical installation from overloads and short circuits. It is a single-phase, 2-pole device operating at 230 volts with a 500 mA differential current. Its selective nature allows for adjustable current settings at 30A, 45A, and 60A, ensuring compliance with NF C 62 411 standards.

Produkt ponadview

Itron EDF 60A 230V Selective Circuit Breaker

Figure 1: Itron EDF 60A 230V Selective Circuit Breaker. A white, rectangular electrical circuit breaker with the Itron logo and specifications printed on its side. It features a blue 'Test' button and a toggle switch.

Główne cechy:

  • 60 A 500 mA subscriber circuit breaker.
  • Provides protection against electrical overloads and short circuits.
  • Selective current adjustment: 30 A, 45 A, and 60 A.
  • Designed for installation on EDF subscriber circuit breaker plates or meter/circuit breaker plates.
  • Conforms to NF C 62 411 standard.
  • Monophase, 230 volts, 2 poles, 500 mA differential.

Konfiguracja i instalacja

Instalację powinien wykonać wyłącznie wykwalifikowany elektryk, zgodnie z lokalnymi przepisami i regulacjami elektrycznymi.

Środki ostrożności:

  • Ensure the main power supply is disconnected before beginning any installation work.
  • Sprawdź, czy objętośćtage and current ratings of the circuit breaker match your electrical system requirements.
  • Stosować odpowiedni sprzęt ochrony osobistej (PPE).

Kroki instalacji:

  1. Identify the appropriate mounting location on an EDF subscriber circuit breaker plate or a meter/circuit breaker plate.
  2. Mount the circuit breaker securely onto the DIN rail. The mounting type is DIN rail mounting.
  3. Connect the incoming phase and neutral conductors to the designated terminals (2 poles).
  4. Connect the outgoing phase and neutral conductors to the protected circuit.
  5. Sprawdź, czy wszystkie połączenia są dobrze dokręcone i bezpieczne.
  6. Set the desired current rating (30A, 45A, or 60A) using the adjustment mechanism on the device. Refer to your electricity provider's specifications for the correct setting.

Instrukcja obsługi

Włączanie/wyłączanie:

  • To turn on the power, push the toggle switch to the 'I' (ON) position.
  • To turn off the power, push the toggle switch to the 'O' (OFF) position.

Testing the Differential Function:

It is recommended to test the differential function regularly (e.g., monthly) to ensure proper operation.

  1. Ensure the circuit breaker is in the 'I' (ON) position.
  2. Press the blue 'Test' button located on the front of the device.
  3. The circuit breaker should trip, moving the toggle switch to the 'O' (OFF) position.
  4. To reset, push the toggle switch fully down, then back up to the 'I' (ON) position.
  5. If the circuit breaker does not trip during the test, contact a qualified electrician for inspection and replacement if necessary.

Konserwacja

The Itron EDF 60A 230V Selective Circuit Breaker requires minimal maintenance. Regular visual inspections and functional testing are recommended.

Rutynowe kontrole:

  • Periodically inspect the circuit breaker for any signs of physical damage, discoloration, or overheating.
  • Ensure all connections remain tight.
  • Perform the differential test as described in the "Operating Instructions" section.

Do not attempt to open or repair the circuit breaker yourself. Refer all servicing to qualified personnel.

Rozwiązywanie problemów

ProblemMożliwa przyczynaRozwiązanie
Częste wyzwalanie wyłączników.Overload, short circuit, or ground fault in the protected circuit.
  • 1. Disconnect appliances from the circuit.
  • 2. Zresetuj wyłącznik automatyczny.
  • 3. If it trips again, there may be a short circuit or ground fault. Contact a qualified electrician.
  • 4. Ensure the total load does not exceed the circuit breaker's rating.
Circuit breaker does not trip when 'Test' button is pressed.Faulty differential mechanism or internal damage.
  • 1. Do not use the circuit breaker.
  • 2. Contact a qualified electrician for inspection and replacement.
Circuit breaker feels hot to the touch.Overload, loose connections, or internal fault.
  • 1. Immediately turn off the main power supply.
  • 2. W celu przeprowadzenia inspekcji należy skontaktować się z wykwalifikowanym elektrykiem.

Specyfikacje

AtrybutWartość
MarkaItron
Numer modeluTAK030151
ASINB07Z4TDBDN
Prąd znamionowy60 A (Adjustable to 30 A, 45 A)
Prąd różnicowy500mA
Tomtage230 V
Liczba słupów2
Typ montażuMontaż na szynie DIN
Wymiary (dł. x szer. x wys.)Wymiary 20.2 x 8 x 7.3 cm
Waga400 gramów
ZgodnośćNF C 62 411

Informacje o gwarancji

Itron products are manufactured to high-quality standards. For specific warranty terms and conditions, please refer to the documentation provided at the time of purchase or contact your local Itron distributor. Keep your proof of purchase for warranty claims.

Wsparcie i kontakt

For technical assistance, troubleshooting beyond this manual, or spare parts information, please contact Itron customer support or your authorized dealer.

Manufacturer: Itron

Więcej informacji znajdziesz na stronie Itron brand page.

© 2024 Itron. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.