This user manual provides comprehensive instructions for the Zerone External S Meter SWR Power Meter, designed specifically for use with Yae FT-857D and FT-897 transceivers. This high-performance meter offers excellent durability and stability, clearly displaying critical parameters such as automatic level control voltage, modulation level, standing wave ratio, and supply voltage.

  • Only applicable for Yae FT-857D and FT-897.
  • Clearly displays the automatic level control voltage, modulation level, standing ratio, and supply voltage.
  • High performance and super stability.
  • Łatwy w obsłudze.
  • High quality and excellent durability.

Konfiguracja i kalibracja

Receive Display Settings

To configure the meter for receive display:

  1. Naciśnij (FUNKCJA) key to enter the setup menu and enable the extended menu.
  2. Obracać (WYBIERAĆ) to call up setup menu item No-061 (MTR ARX SEL).
  3. Obracać (DIAL) to select an external instrument display option from the following:
    • -SYG
    • -CTR
    • -VLT
    • -N / A
    • -FS: Buckle in the instrument 1mA full scale output calibration standard external instruments.
    • -WYŁĄCZONY
  4. Naciskać (FUNKCJA) to save the settings and exit the setup menu.

Emission Display Settings

To configure the meter for emission display:

  1. Naciśnij (FUNKCJA) key to enter the setup menu and enable the extended menu.
  2. Obracać (WYBIERAĆ) to call up setup menu item No-061 (MTR ARX SEL).
  3. Obracać (DIAL) to select an external instrument display option from the following:
    • -Zasilanie
    • -ALC
    • -MOD
    • -SWR
    • -VLT
    • -N / A
    • -WYŁĄCZONY

Metoda kalibracji

To calibrate the meter for accurate readings:

  1. Naciśnij (FUNKCJA) key to enter the setup menu and enable the extended menu.
  2. Obracać (WYBIERAĆ) to call up setup menu item No-060 (MTR ARX SEL).
  3. Obracać (DIAL) wybrać FS.
  4. Using a small flathead screwdriver, adjust the calibration adjustment hole at the rear of the unit until the meter pointer reaches full scale.
  5. Kalibracja jest zakończona.
Zerone External S Meter with cable

Figure 1: The Zerone External S Meter with its connecting cable.

Close-up of Zerone S Meter display face

Rysunek 2: Szczegółowy view of the meter's display face, showing SIG, PWR, SWR, MOD, VOLT, and DISC scales.

Obsługa miernika

Once properly set up and calibrated, the Zerone External S Meter provides real-time readings for various radio parameters. The meter's needle will indicate values on the selected scale (SIG, PWR, SWR, MOD, VOLT, DISC) based on your radio's operation mode (receive or transmit).

Refer to your Yaesu FT-857D or FT-897 transceiver's manual for specific interpretations of these readings in different operating scenarios.

Zerone S Meter displaying various parameters

Figure 3: The meter clearly displays automatic level control voltage, modulation level, standing wave ratio, and supply voltage.

Konserwacja

The Zerone External S Meter is designed for durability. Regular maintenance is minimal but important for continued accuracy and longevity.

  • Keep the meter clean and free from dust. Use a soft, dry cloth to wipe the casing and display face.
  • Unikaj wystawiania miernika na działanie ekstremalnych temperatur lub bezpośredniego światła słonecznego przez dłuższy czas.
  • If the meter's pointer does not return to zero when the unit is off or disconnected, it may be due to transit bumps. In such cases, carefully adjust the self-zeroing screw located on the mask-side of the instrument. This screw is typically black.
Zerone S Meter with dimensions

Figure 4: Dimensions of the Zerone External S Meter: 6.7 cm * 7 cm * 6 cm.

Rozwiązywanie problemów

This section addresses common issues you might encounter with your Zerone External S Meter.

Hidden Menu Access

If you are unable to find menu items No-060 or No-061 in your radio's setup menu, these menus might be hidden. To access them:

  1. Naciśnij i przytrzymaj F key on your radio to open the menu settings.
  2. Set the relevant menu option to ON to reveal the hidden menus.
  3. Naciśnij F key again to exit and save the settings.

Static Pointer / Zeroing Issues

The instrument is calibrated at delivery. However, transit bumps can sometimes cause the pointer to not rest at zero. If this occurs:

  • Locate the black self-zeroing screw on the mask-side of the instrument.
  • Gently adjust this screw with a small flathead screwdriver until the pointer rests at the zero mark.

Specyfikacje

FunkcjaSzczegół
MarkaZerone
Numer modeluZer onekda4y0nmoz
Kompatybilne radiaYaesu FT-857D, FT-897
Waga przedmiotu10.2 uncji (0.29 kilograma)
Rozmiar ekranu3.5 cali
Kraj pochodzeniaChiny
UPC745781109282
Pierwszy dostępny12 sierpnia 2019 r.

Informacje o gwarancji

Specific warranty details for the Zerone External S Meter are not provided in this manual. Please refer to the product packaging or contact Zerone customer support for information regarding warranty coverage and terms.

Obsługa klienta

For technical assistance, troubleshooting, or general inquiries about your Zerone External S Meter, please visit the official Zerone store or contact their customer service department. Contact information can typically be found on the product packaging or the manufacturer's official webstrona.

Możesz również odwiedzić Zerone Store on Amazon Aby uzyskać więcej informacji o produkcie i zasobach pomocy.

© 2024 Zerone. All rights reserved.