Foset REGEL-4A

Foset REGEL-4A Electric Shower Head Instruction Manual

Model: REGEL-4A (45155)

Brand: Foset

1. Wprowadzenie

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Foset REGEL-4A Electric Shower Head. Please read these instructions thoroughly before installation and use, and retain them for future reference. The Foset REGEL-4A is designed to provide instant hot water with four adjustable temperature levels, ensuring a comfortable showering experience.

2. Informacje dotyczące bezpieczeństwa

OSTRZEŻENIE: Ryzyko porażenia prądem. Installation must be performed by a qualified electrician in accordance with all local electrical codes and regulations. Failure to follow these instructions can result in electric shock, fire, or property damage.

  • Ensure the electrical installation includes an independent circuit directly from the main load center.
  • A circuit breaker with a minimum capacity of 50 A (for 127 V systems) is required.
  • Use appropriate wire gauge: 10AWG for distances less than 30 meters, and 8AWG for distances greater than 30 meters from the main electrical panel.
  • Do not use extension cords, adapters, or multiple outlets with this appliance.
  • Ensure proper grounding (Green wire) is connected.
  • Never operate the shower head if it is damaged or malfunctioning.
  • Before any maintenance or cleaning, always disconnect the power supply to the shower head at the circuit breaker.

3. Zawartość opakowania

Przed przystąpieniem do instalacji sprawdź, czy wszystkie komponenty są obecne i nieuszkodzone.

Foset REGEL-4A Electric Shower Head components including the shower head, arm, hose, sprayer, and support.

Rysunek 1: Components of the Foset REGEL-4A Electric Shower Head. This image displays the main electric shower head unit, the shower arm, a 1.50 meter PVC hose, a separate sprayer, and a wall-mounted support for the sprayer.

  • Foset REGEL-4A Electric Shower Head
  • Ramię prysznicowe
  • 1.5 Meter PVC Hose
  • Sprayer (Alcachofa de ducha)
  • Sprayer Support
  • Mounting Tools (Herramientas de montaje)

4. Specyfikacje

FunkcjaSpecyfikacja
Numer modeluREGEL-4A (45155)
MarkaFoset
ProducentTruper
KolorNiebieski
Materiał (korpus)Tworzywo polipropylenowe
Materiał (uchwyt)Metal and/or Plastic
Poziomy temperatury4 (Tibia, Caliente, Muy Caliente)
Długość węża1.5 metrów
Wymiary (dł. x szer. x wys.)Wymiary 14.5 x 14.5 x 12.7 cm
Waga400 gramów
Wymagania dotyczące zasilania127 V, minimum 50 A circuit breaker
Foset REGEL-4A Electric Shower Head showing a diameter of 14.5 cm.

Rysunek 2: Dimensions of the Foset REGEL-4A Electric Shower Head, indicating a diameter of 14.5 cm.

5. Instalacja

5.1 Wymagania przed instalacją

  • Ciśnienie wody: The water tank (tinaco) height must be between 1 and 10 meters above the shower head for optimal water pressure. If the height is greater than 5 meters, a reducer may be required at the base of the water tank.
  • Dostawy prądu: As detailed in Section 2, ensure a dedicated 127 V circuit with a 50 A breaker and appropriate wire gauge (10 AWG for <30m, 8 AWG for >30m).

5.2 Fizyczna instalacja

  1. Zakręć główne dopływy wody do miejsca instalacji.
  2. Mount the shower arm securely to the wall, ensuring it is level and properly sealed to prevent leaks.
  3. Attach the Foset REGEL-4A Electric Shower Head to the shower arm. Hand-tighten first, then use a wrench if necessary, being careful not to overtighten.
  4. Connect the 1.5-meter PVC hose to the shower head and the sprayer. Mount the sprayer support to a convenient location on the wall.
  5. Turn on the main water supply and check for any leaks. Address any leaks before proceeding.

5.3 Podłączenie elektryczne

WAŻNY: Ensure power is OFF at the main circuit breaker before making any electrical connections.

Diagram illustrating the electrical installation of the Foset REGEL-4A electric shower head, showing connections to a circuit breaker, wire gauges, and water tank height requirements.

Rysunek 3: Electrical Installation Diagram. This diagram shows the required independent electrical connection, wire color coding (Blue: Line, White: Neutral, Green: Ground), recommended wire gauges based on distance, and the necessary water tank height for proper operation.

  1. Identify the electrical wires from the shower head: Blue (Line), White (Neutral), and Green (Ground).
  2. Connect these wires to the corresponding wires of your dedicated electrical circuit. Ensure secure connections using appropriate electrical connectors.
  3. Verify that the ground wire (Green) is properly connected to the electrical system's ground.
  4. Once all connections are secure and insulated, close the electrical junction box.
  5. Przed przywróceniem zasilania sprawdź dokładnie wszystkie połączenia.

6. Działanie

  1. After installation and before turning on the electrical power, allow water to flow through the shower head for at least 30 seconds to ensure the heating element is fully submerged. This prevents damage to the heating element.
  2. Restore power to the shower head at the circuit breaker.
  3. The Foset REGEL-4A features a selector for four temperature levels:
    • Wyłączony: Brak ogrzewania.
    • Tibia: Ciepła woda.
    • Caliente: Tarapaty.
    • Muy Caliente: Bardzo gorąca woda.
  4. Rotate the selector on the shower head to your desired temperature setting.
  5. Adjust the water flow from your faucet to fine-tune the temperature. Lower flow generally results in hotter water, while higher flow results in cooler water for a given setting.

7. Konserwacja

  • Czyszczenie: Regularly clean the exterior of the shower head with a soft, damp cloth. Do not use abrasive cleaners or solvents, as these can damage the polypropylene body.
  • Czyszczenie dysz: Periodically check the shower nozzles for mineral deposits or blockages. Gently clean them with a soft brush or by hand to maintain optimal water flow.
  • Odwapnianie: In areas with hard water, mineral buildup can affect performance. If water flow is reduced or heating efficiency decreases, the internal components may require descaling. Consult a qualified technician for internal descaling procedures.
  • Zimowanie (jeśli dotyczy): If the shower head is in an unheated area subject to freezing temperatures, ensure the water supply is drained to prevent damage from freezing.

8. Rozwiązywanie Problemów

ProblemMożliwa przyczynaRozwiązanie
Brak ciepłej wody
  • Brak prądu
  • Zadziałał wyłącznik automatyczny
  • Niewystarczający przepływ wody
  • Awaria elementu grzejnego
  • Check power supply to the shower head.
  • Zresetuj wyłącznik automatyczny.
  • Ensure adequate water flow before turning on power.
  • W celu przeprowadzenia inspekcji i naprawy należy skontaktować się z wykwalifikowanym technikiem.
Woda nie jest wystarczająco gorąca
  • Temperature selector set too low
  • Nadmierny przepływ wody
  • Niska temperatura wody dopływającej
  • Adjust the temperature selector to a higher setting.
  • Reduce water flow from the faucet.
  • This is normal in colder climates; select a higher temperature setting.
Słaby przepływ wody
  • Zatkane dysze
  • Niskie ciśnienie wody
  • Clean the shower nozzles.
  • Check the main water supply and ensure the water tank height meets requirements (1-10 meters).

9. Gwarancja i wsparcie

Foset products are manufactured under strict quality control standards. For warranty information, please refer to the warranty card included with your product or visit the official Foset website. For technical support, replacement parts, or service inquiries, please contact Foset customer service through their official channels.

Producent: Truper

Marka: Foset

Ask a question about this manual