1. Wprowadzenie
This manual provides essential information for the safe and efficient operation and maintenance of your FavorCOOL 3.6 CFM Single Stage Rotary Vane Vacuum Pump, Model FC-36T. Please read all instructions carefully before use to ensure proper function and longevity of the unit.

Figure 1: FavorCOOL 3.6 CFM Vacuum Pump, Model FC-36T. This image shows the overall design of the vacuum pump, highlighting its compact and portable nature.
2. Informacje dotyczące bezpieczeństwa
Aby zapobiec obrażeniom ciała lub uszkodzeniu sprzętu, należy zawsze przestrzegać następujących środków ostrożności:
- Podczas pracy pompy należy upewnić się, że jest ona umieszczona na stabilnej i równej powierzchni.
- Zawsze należy nosić odpowiedni sprzęt ochrony osobistej, obejmujący okulary ochronne i rękawice.
- Do not operate the pump without sufficient vacuum pump oil. Check the oil level before each use.
- Przed przystąpieniem do jakichkolwiek prac konserwacyjnych lub napraw należy odłączyć zasilanie.
- Avoid direct contact with refrigerant.
- Stosować wyłącznie w dobrze wentylowanych pomieszczeniach.
3. Konfiguracja
Before operating the vacuum pump, proper setup is crucial:
3.1 Identyfikacja komponentów

Figure 2: Labeled components of the FavorCOOL vacuum pump, including the handle, oil intake, sight glass, fan cover, motor, and non-slip base.
3.2 Initial Oil Filling
- Remove the oil cap/oil mist trap from the top of the pump.
- Carefully pour vacuum pump oil into the oil intake until the level is between the 'MIN' and 'MAX' marks on the sight glass. The oil capacity is 300 ml.
- Reinstall the oil cap/oil mist trap securely.

Rysunek 3: Zbliżenie view of the vacuum pump's oil reservoir and sight glass, showing the 'MAX' and 'MIN' indicators for proper oil level.
3.3 Podłączanie węży
Connect the appropriate hoses to the vacuum pump's 1/4" flare intake port and to your HVAC or automotive AC system. Ensure all connections are tight to prevent leaks.
4. Instrukcja obsługi
This section outlines the general procedure for using the vacuum pump for HVAC and automotive AC systems.
4.1 Vacuuming the System
- Ensure the vacuum pump is properly filled with oil and connected to the system via manifold gauges.
- Open the valves on your manifold gauge set.
- Turn on the vacuum pump. The pump will draw the system down to approximately 37.5 microns (5 Pa).
- Continue vacuuming for 10-15 minutes to ensure all moisture and non-condensable gases are removed.
- After vacuuming, close the manifold gauge valves, then disconnect the yellow hose from the vacuum pump, and finally turn off the vacuum pump to prevent oil backflow.
- Monitor the low-pressure gauge for 5-10 minutes. If the needle remains steady, there is no leak.

Figure 4: The FavorCOOL vacuum pump connected to an automotive AC system, demonstrating its application in vehicle maintenance.
4.2 Refrigerant Recharging
After successful vacuuming, you can proceed with recharging the system:
- Connect the yellow hose from the manifold gauge set to the refrigerant source (e.g., R134a, R410a, R22).
- Purge air from the yellow hose by briefly opening and closing the manifold valve.
- Open the low-side valve on the manifold gauge set to allow refrigerant to enter the system.
- Monitor the pressure on the gauges and the amount of refrigerant charged according to the system's specifications.
- Once the desired amount is charged, close the manifold gauge valves and disconnect the hoses.
Video 1: This video demonstrates the process of vacuuming an AC system and then recharging it with refrigerant using a vacuum pump and manifold gauge set. It covers connecting hoses, operating the pump, and monitoring pressure.
5. Konserwacja
Regularna konserwacja zapewnia optymalną wydajność i wydłuża żywotność pompy próżniowej.
5.1 Kontrola poziomu oleju
Check the oil level before each use. The oil should be clear and between the 'MIN' and 'MAX' indicators on the sight glass. If the oil is cloudy or discolored, it needs to be changed.
5.2 Wymiana oleju
To change the oil, drain the old oil through the oil drain valve at the bottom of the pump. Dispose of used oil responsibly. Refill with new vacuum pump oil as described in Section 3.2.
6. Rozwiązywanie Problemów
If you encounter issues with your vacuum pump, refer to the detailed troubleshooting guide in the full user manual for common faults and solutions. Proper operation is key to preventing malfunctions.
7. Specyfikacje
| Funkcja | Specyfikacja |
|---|---|
| Marka | Faworyzuję COOL |
| Model | FC-36T |
| Przepływ | 3.6 stopy sześcienne na minutę |
| Moc silnika | 1 / 4 HP |
| Najlepszy odkurzacz | 37.5 mikronów (5 Pa) |
| Tomtage/Częstotliwość | 110V/60Hz |
| Pojemność oleju | 300 ml |
| Porty wlotowe | 1/4" Flare |
| Tworzywo | Aluminum, Copper, Glass, Plastic, Stainless Steel |
| Waga przedmiotu | 11 funtów |
| Wymiary produktu | 10.6 x 4.6 x 8.5 cala |
| UPC | 850007139025 |
8. Gwarancja i wsparcie