This manual provides instructions for the installation, operation, and maintenance of the Keenso Stainless Steel Liquid Level Float Switch. This device is designed for reliable liquid level detection in various applications, including water tanks and pools. It features a durable stainless steel construction and is suitable for use in environments with temperatures up to 120°C and pressures up to 5 MPa.

2. Koniec produktuview

The Keenso Liquid Level Float Switch is a robust sensor designed for accurate liquid level monitoring. Its primary components include a stainless steel body, a floating ball, and electrical wiring for connection. The switch operates by detecting the position of the floating ball, which changes with the liquid level, thereby opening or closing an electrical contact.

Detailed diagram of the Keenso Liquid Level Float Switch with dimensions and specifications.

Rysunek 2.1: Detailed diagram showing the dimensions (e.g., 78mm total length, 28mm float diameter, M10 thread) and key electrical specifications of the float switch. This includes working voltage (0-220V), working current (0.5-1A), material (SUS304 & SUS316), operating temperature (0-120°C), maximum pressure (5 MPa), and maximum power/switching current for low and high voltage aplikacje.

Z bliska view of the Keenso Liquid Level Float Switch highlighting its stainless steel construction and internal components.

Rysunek 2.2: This image provides a close-up of the float switch, detailing its construction. It highlights that the floating ball is made of 304 stainless steel, and the clip spring is 316L material. It also notes the device's ability to operate at temperatures up to 120°C and withstand 5 MPa pressure, making it suitable for various environments. The working voltage range of AC 0-220V and DC 0-200V is also indicated, confirming its compatibility with most power sources.

Główne cechy:

  • Szerokie zastosowanie: Suitable for various liquid level detection tasks in small to medium pressure storage tanks and pools.
  • Trwały materiał: Constructed from SUS304 and SUS316L stainless steel for corrosion resistance and reliability.
  • Odporność na wysoką temperaturę: Operates effectively at temperatures up to 120°C.
  • High Pressure Resistance: Withstands pressures up to 5 MPa.
  • Elastyczna instalacja: Supports both vertical and horizontal mounting configurations.

3. Specyfikacje

Parametr Wartość
Objętość roboczatage 0 ~ 220 V
Prąd roboczy 0.5 - 1 A
Tworzywo SUS304 & SUS316L Stainless Steel
Temperatura pracy 0 ~ 120 °C
Maksymalna tolerancja temperatury 120 °C
Ciśnienie robocze 1 MPa
Maximum Withstand Pressure 5 MPa
Maximum Power (Low Voltage) 10 W
Maximum Power (High Voltage) 50 W
Maximum Switching Current (Low Voltage) 0.5 A
Maximum Switching Current (High Voltage) 1.5 A
Wymiary produktu (dł. x szer. x wys.) Approx. 7.5 x 7.5 x 7.5 cm (75mm length)
Technologia czujników Czujnik kontaktu
Typ montażu Wall Mount (typical for side installation)

4. Konfiguracja i instalacja

Proper installation is crucial for the accurate and reliable operation of the float switch. Follow these steps carefully:

  1. Wybierz miejsce montażu: Select a location in your tank or container where the desired liquid level needs to be detected. The switch can be mounted vertically or horizontally. For side installation, ensure the float can move freely.
  2. Zabezpiecz przełącznik: Use the M10 threaded connection to securely fasten the float switch to the tank wall or a suitable mounting bracket. Ensure a watertight seal if installing through a tank wall.
  3. Okablowanie: Connect the two wires from the float switch to your control circuit.
    • The float switch acts as a simple contact closure. When the liquid level changes, the float moves, and the internal reed switch opens or closes.
    • Ważny: This floating ball switch cannot directly control high-power devices such as solenoid valves or AC contactors. For such applications, an intermediate small relay must be used to handle the higher current and voltagi wymagania.
  4. Funkcjonalność testu: Before full deployment, test the switch by manually raising or lowering the liquid level (or simulating it) to ensure the contact changes as expected.
Keenso float switch installed in an outdoor irrigation system, demonstrating a typical application.

Rysunek 4.1: The float switch shown installed in an outdoor setting, likely for irrigation or water management, illustrating a practical application where liquid level monitoring is required.

Z bliska view of the Keenso float switch showing its side installation capability.

Rysunek 4.2: Szczegółowy view of the float switch, emphasizing its design for side installation. This configuration allows for level detection from the side of a tank or reservoir.

5. Instrukcja obsługi

The float switch operates based on the principle of buoyancy. As the liquid level rises or falls, the stainless steel float moves, causing an internal reed switch to activate or deactivate. This change in contact state can then be used to trigger alarms, control pumps, or activate other devices via a relay.

  • Normalna praca: The switch will maintain its contact state (normally open or normally closed) until the liquid level causes the float to move past its activation point.
  • Reversing Contact Operation: To reverse the contact's behavior (e.g., change from normally open to normally closed when the float rises, or vice-versa), you can physically invert the float ball on the stem. This allows for flexibility in setting up high-level or low-level detection.
  • Zakres sterowania: The floating ball travel is approximately 10mm, which defines the control range. This allows for two combinations: one for a longer detection range and one for a shorter, more precise range, depending on how the float is positioned.
Keenso float switch submerged in water, demonstrating its function in a liquid environment.

Rysunek 5.1: The float switch operating within a liquid, illustrating how the float mechanism responds to changes in water level to activate the internal switch.

6. Konserwacja

The Keenso Liquid Level Float Switch is designed for minimal maintenance due to its durable stainless steel construction. However, periodic checks are recommended to ensure optimal performance:

  • Sprawdź pod kątem przeszkód: Regularly check the float and stem for any debris, scale buildup, or foreign objects that might impede the float's free movement. Clean as necessary.
  • Sprawdź okablowanie: Ensure all electrical connections are secure and free from corrosion or damage.
  • Sprawdź działanie: Periodically test the switch's functionality by manually changing the liquid level or simulating a change to confirm it activates correctly.
  • Czystość: If operating in environments with potential for buildup, gently clean the stainless steel components with a non-abrasive cleaner and soft cloth.

7. Rozwiązywanie Problemów

If the float switch is not functioning as expected, consider the following troubleshooting steps:

Problem Możliwa przyczyna Rozwiązanie
Switch does not activate/deactivate
  • Float obstructed or stuck
  • Nieprawidłowe okablowanie
  • Reed switch failure
  • Liquid level not reaching activation point
  • Inspect and clear any obstructions around the float.
  • Verify wiring connections against the circuit diagram. Ensure a relay is used for high-power loads.
  • Test the switch continuity with a multimeter. Replace if faulty.
  • Adjust mounting position or verify expected liquid levels.
Niespójne lub błędne działanie
  • Excessive turbulence in liquid
  • Luźne połączenia
  • Float ball damaged
  • Consider adding a baffle or stilling tube around the float switch to reduce turbulence.
  • Sprawdź i dokręć wszystkie połączenia elektryczne.
  • Inspect float ball for damage; replace switch if necessary.
Switch operates in reverse logic Float ball installed upside down Physically invert the float ball on the stem to reverse the contact operation.
Not working with 12V system Potential compatibility issue or specific wiring requirement for low voltage. Ensure the 12V circuit is correctly wired and that the load does not exceed the low voltage maximum power/current ratings (10W / 0.5A). Test with a multimeter to confirm switch functionality.

8. Informacje o gwarancji

The Keenso Stainless Steel Liquid Level Float Switch comes with a 180-dniowa gwarancja from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage resulting from improper installation, misuse, accidents, or unauthorized modifications. Please retain your proof of purchase for warranty claims.

9. Wsparcie

For any questions, technical assistance, or support regarding your Keenso Liquid Level Float Switch, please do not hesitate to contact our customer service. We are committed to providing assistance and resolving any issues you may encounter.

Proszę zapoznać się z informacjami sprzedawcy webSzczegółowe dane kontaktowe znajdziesz na stronie internetowej lub w dokumentacji zakupu.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.