AUTOOL LM 120

AUTOOL LM120+ Cyfrowy miernik kolektora

Instrukcja obsługi

1. Koniec produktuview

The AUTOOL LM120+ Digital Manifold Gauge is a professional instrument designed for comprehensive testing and maintenance of HVAC and refrigeration systems. It provides accurate digital readings for pressure, temperature, and vacuum, facilitating efficient diagnosis and servicing of air conditioners and refrigerators. This kit includes the main gauge unit, temperature probes, and connecting hoses, offering a complete solution for refrigerant management.

AUTOOL LM120+ Digital Manifold Gauge kit with hoses and temperature clips

Figure 1: AUTOOL LM120+ Digital Manifold Gauge and included accessories.

2. Informacje dotyczące bezpieczeństwa

Please read and understand all safety warnings and instructions before operating the AUTOOL LM120+ Digital Manifold Gauge. Failure to follow these instructions may result in equipment damage, personal injury, or property damage.

  • Always wear appropriate personal protective equipment (PPE), including safety glasses and gloves, when working with refrigerants.
  • Ensure proper ventilation in the work area to prevent accumulation of refrigerant gases.
  • Nie wystawiaj urządzenia na działanie ekstremalnych temperatur, bezpośredniego światła słonecznego i wilgoci.
  • Handle refrigerant hoses and connections with care to prevent leaks and refrigerant burns.
  • Nie podejmuj prób naprawy ani modyfikacji urządzenia. Wszelkie prace serwisowe powierzaj wykwalifikowanemu personelowi.
  • Verify that the selected refrigerant type on the gauge matches the refrigerant in the system being tested.
  • Trzymaj urządzenie poza zasięgiem dzieci i osób nieupoważnionych.

3. Zawartość opakowania

Po otwarciu opakowania prosimy sprawdzić, czy wszystkie wymienione poniżej elementy znajdują się w opakowaniu i są w dobrym stanie:

  • 1 x AUTOOL LM120+ Digital Manifold Gauge
  • 2 x Temperature Clamp Sondy
  • 3 x Refrigerant Hoses (Red, Blue, Yellow)
  • 1 x Instrukcja obsługi (ten dokument)
  • 1 x Storage Case (if included with specific model variant)

4. Funkcje produktu

The AUTOOL LM120+ offers a range of advanced features for precise HVAC system analysis:

  • Evaporation Pressure & Temperature Test: Measures the maximum pressure when refrigerant changes from liquid to gas and the lowest temperature during this phase. This helps assess the efficiency of the cooling cycle.
    Digital Manifold Gauge displaying evaporation pressure and temperature readings.

    Figure 2: Evaporation Pressure and Temperature Test display.

  • Condensing Pressure & Temperature Test: Determines the minimum pressure when refrigerant changes from gas to liquid and the maximum temperature during this phase. Lower values indicate higher cooling cycle efficiency.
    Digital Manifold Gauge displaying condensing pressure and temperature readings.

    Figure 3: Condensing Pressure and Temperature Test display.

  • High / Low Pressure Temperature Test: Measures the temperature of the refrigerant within the high-pressure and low-pressure pipelines of the air conditioning system.
    Digital Manifold Gauge displaying high and low pressure temperature readings from T1 and T2 sensors.

    Figure 4: High/Low Pressure Temperature Test display.

  • Pressure Leakage Test: Calculates the pressure difference between an initial and a second test pressure to identify potential refrigerant leaks in the system.
    Digital Manifold Gauge performing a pressure leakage test, showing time elapsed and pressure difference.

    Figure 5: Pressure Leakage Test display.

  • Refrigerant Type Setting & Observation Window: Allows selection of the appropriate refrigerant type for accurate measurements and provides a viewable window to observe the refrigerant filling status.
    Digital Manifold Gauge showing refrigerant type selection (R11) and a view okna obserwacyjnego czynnika chłodniczego.

    Figure 6: Refrigerant Type Setting and Observation Window.

  • Inteligentny wyświetlacz cyfrowy: Provides clear and intelligent digital display of test results for pressure and temperature, reducing diagnostic time.
    Close-up of the AUTOOL LM120+ digital display showing various readings.

    Figure 7: Smart Digital Display.

5. Układ urządzenia i elementy sterujące

Familiarize yourself with the components and controls of the LM120+ Digital Manifold Gauge:

Diagram of AUTOOL LM120+ Digital Manifold Gauge with numbered parts and their descriptions.

Figure 8: LM120+ Digital Manifold Gauge Components.

Tabela 1: Opisy komponentów
NIE.CzęśćOpis
1HakFor hanging the unit during operation.
2Clamp-on Temperature Probe SocketConnection point for temperature clamp sondy.
3Wyświetlacz LCDShows pressure, temperature, and other readings.
4Przycisk funkcyjnyUsed to cycle through different functions.
5Przycisk Uruchom/ZatrzymajStarts or stops measurement processes.
6Przycisk ZeroResets pressure readings to zero.
7R+/R- Refrigerant Type Selection ButtonsUsed to select the type of refrigerant.
8Przycisk ściemnianiaReguluje jasność wyświetlacza.
9Przycisk jednostkiChanges measurement units (e.g., kPa, psi, bar).
10Przycisk ° C / ° FPrzełącza wyświetlanie temperatury pomiędzy stopniami Celsjusza i Fahrenheita.
11Przycisk zasilaniaWłącza lub wyłącza urządzenie.
12Refrigerant Observation WindowUmożliwia wizualną kontrolę przepływu czynnika chłodniczego.
13Zawór niskiego ciśnieniaControls flow to the low-pressure side.
14Zawór wysokiego ciśnieniaControls flow to the high-pressure side.
151/4 inch Low Pressure InletConnection port for low-pressure hose.
16Zawór bezpieczeństwaUwalnia nadmierne ciśnienie.
171/4 inch High Pressure InletConnection port for high-pressure hose.
18Refrigerant Inlet / Vacuum Pump InletCentral connection for refrigerant charging or vacuum pump.

6. Konfiguracja

  1. Montaż baterii: Open the battery compartment on the back of the unit and insert the required batteries (typically AA or AAA, refer to device markings if present). Ensure correct polarity.
  2. Włączanie: Naciśnij Przycisk zasilania (11) to turn on the device. The LCD display (3) should illuminate.
  3. Wybór jednostki: Naciśnij Przycisk jednostki (9) to cycle through available pressure units (e.g., kPa, psi, bar) and the Przycisk ° C / ° F (10) for temperature units. Select your preferred units.
  4. Kalibracja zera: Before connecting to a system, ensure all valves (13, 14) are closed and the hoses are disconnected. Press the Przycisk Zero (6) to calibrate the pressure sensors to zero. This ensures accurate readings.
  5. Podłącz sondy temperatury: Plug the temperature clamp probes into the Clamp-on Temperature Probe Sockets (2) on the top of the unit. Attach the clamps securely to the high and low-pressure lines of the HVAC system.
    AUTOOL LM120+ connected with hoses and temperature clamps.

    Figure 9: Connecting temperature probes and hoses.

  6. Podłącz węże:
    • Connect the blue hose to the Low Pressure Inlet (15) on the gauge and to the low-pressure service port of the HVAC system.
    • Connect the red hose to the High Pressure Inlet (17) on the gauge and to the high-pressure service port of the HVAC system.
    • Connect the yellow (or central) hose to the Refrigerant Inlet / Vacuum Pump Inlet (18) on the gauge. This hose will be used for vacuuming, charging, or connecting to a recovery unit.
    Close-up of the manifold gauge's brass valve connections.

    Rysunek 10: Szczegółowy view of hose connection points.

7. Instrukcja obsługi

This section outlines common operational procedures for the LM120+.

7.1. Selecting Refrigerant Type

  1. Po włączeniu urządzenia naciśnij przycisk R+/R- Buttons (7) to scroll through the available refrigerant types (e.g., R134a, R22, R410a).
  2. Select the refrigerant type that matches the system you are working on. This is crucial for accurate pressure-temperature conversions.

7.2. Performing Pressure and Temperature Tests

  1. Ensure hoses and temperature probes are correctly connected to the system.
  2. Slowly open the high-pressure (red) and low-pressure (blue) valves on the manifold to allow refrigerant to flow into the gauge.
  3. The LCD display will show real-time pressure readings for both high and low sides, along with corresponding saturation temperatures based on the selected refrigerant.
  4. The temperature probes will display the actual line temperatures (T1 and T2).
  5. Compare the saturation temperatures with the actual line temperatures to determine superheat and subcooling, which are critical for system diagnosis.

7.3. Performing a Pressure Leakage Test

  1. Connect the gauge to the system and pressurize it to the desired test pressure (ensure system can handle the pressure).
  2. Zamknąć wszystkie zawory kolektora.
  3. Naciśnij Przycisk funkcyjny (4) to navigate to the leakage test mode.
  4. Naciśnij Przycisk Uruchom/Zatrzymaj (5) to start the leakage test timer. The gauge will record the initial pressure.
  5. Allow the test to run for a specified period (e.g., 15-30 minutes, or as per system manufacturer's recommendations).
  6. The display will show the elapsed time and the pressure difference. A significant drop in pressure indicates a leak.
  7. Naciskać Przycisk Uruchom/Zatrzymaj (5) again to stop the test.

7.4. Refrigerant Charging/Evacuation

The LM120+ can be used in conjunction with a vacuum pump and refrigerant tank for system evacuation and charging. Always refer to the specific HVAC system's service manual for proper procedures and refrigerant amounts.

  1. Ewakuacja: Connect the yellow hose to a vacuum pump. Open the manifold valves and the vacuum pump valve to evacuate the system to the desired vacuum level. Monitor the vacuum reading on the gauge.
  2. Ładowanie: After evacuation, close the manifold valves and disconnect the vacuum pump. Connect the yellow hose to a refrigerant tank. Purge the yellow hose of air. Slowly open the appropriate manifold valve (low side for vapor charge, high side for liquid charge with caution) to allow refrigerant into the system. Monitor pressure and temperature readings.

8. Konserwacja

  • Czyszczenie: Wipe the device and hoses with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure no moisture enters the electrical components.
  • Składowanie: Store the LM120+ in its original case or a protective container in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Wymiana baterii: If the display becomes dim or the device does not power on, replace the batteries. Ensure the device is off before replacing batteries.
  • Hose and Seal Inspection: Regularly inspect hoses for cracks, wear, or damage. Check O-rings and seals on connections for integrity to prevent leaks. Replace worn components as needed.

9. Rozwiązywanie Problemów

Tabela 2: Typowe problemy i rozwiązania
ProblemMożliwa przyczynaRozwiązanie
Urządzenie nie włącza się.Niski poziom naładowania baterii lub rozładowane baterie; nieprawidłowa instalacja baterii.Wymień baterie na nowe, zwracając uwagę na prawidłową biegunowość.
Niedokładne odczyty ciśnienia.Gauge not zeroed; incorrect refrigerant selected; sensor malfunction; hose leaks.Perform zero calibration; verify refrigerant type; check hose connections for leaks; contact support if issue persists.
Temperature readings are incorrect or absent.Temperature probes not connected properly; damaged probes.Ensure probes are fully inserted into sockets; check probe cables for damage; replace probes if faulty.
Wyświetlacz jest przyciemniony lub migocze.Low batteries; display settings.Replace batteries; use the Dimming Button (8) to adjust brightness.
Cannot select refrigerant type.Buttons not responding; device malfunction.Ensure buttons are pressed firmly; restart the device; contact support.

10. Specyfikacje

Tabela 3: Specyfikacje techniczne
ParametrWartość
MarkaAUTOOL
Numer modeluLM120
Wymiary produktu (dł. x szer. x wys.)Ok. 210 mm x 120 mm x 65 mm (8.27 cala x 4.72 cala x 2.56 cala)
Waga przedmiotu950 gram
Rozmiar ekranu12 Inches (display area, not physical device size)
Kompatybilność z czynnikiem chłodniczymMultiple common refrigerants (e.g., R134a, R22, R410a, etc.)
Jednostki ciśnieniakPa, psi, bar (selectable)
Jednostki temperatury°C, °F (selectable)

11. Gwarancja i wsparcie

For warranty information, technical support, or service inquiries regarding your AUTOOL LM120+ Digital Manifold Gauge, please contact AUTOOL customer service directly. Refer to the product packaging or the official AUTOOL webna naszej stronie znajdziesz najnowsze dane kontaktowe.

Please have your product model number (LM 120) and purchase information ready when contacting support.

© 2024 AUTOOL. Wszelkie prawa zastrzeżone.

Niniejsza instrukcja ma charakter wyłącznie informacyjny. Dane techniczne mogą ulec zmianie bez powiadomienia.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.