DollaTek JM-101

DollaTek JM-101 Optical Blue Light Fingerprint Sensor Module

Model: JM-101 | Brand: DollaTek

Produkt ponadview

The DollaTek JM-101 Fingerprint Sensor Module is an integrated optical fingerprint processing unit designed for various applications, including security and access control systems. It combines optical path and fingerprint processing components into a compact and efficient module. This manual provides essential information for setting up, operating, and maintaining your JM-101 sensor module, particularly for use with platforms like Arduino Uno R3.

Główne cechy

  • Integrated optical path and fingerprint processing for efficient operation.
  • Compact size and low power consumption, suitable for embedded projects.
  • Simple interface for ease of integration.
  • High reliability and fast recognition speed for quick authentication.
  • Good adaptability to both wet and dry fingers, enhancing usability.
  • High-speed fingerprint search capability for large databases.
  • Communication interface: USB and UART for versatile connectivity.
  • Wymiary: 23.3 x 20.3 x 48.1 mm.

Dane techniczne

SpecyfikacjaWartość
Objętość zasilaniatagePrąd stały 3.3 V
Prąd roboczy<60 mA
Prąd szczytowy<60mA
Fingerprint Image Entry Time<1.0 sekund
Window AreaWymiary: 15.3 × 18.2 mm
Rezolucja500 dpi
Interfejs komunikacyjnyUSB, UART
WymiaryWymiary: 23.3 x 20.3 x 48.1 mm
Waga20 gramów

Konfiguracja i połączenie

Opis pinów

The JM-101 module typically uses a 6-pin connector. The wires are color-coded for easier identification. Refer to the image below for common pin assignments.

DollaTek JM-101 Fingerprint Sensor Module with multi-colored connecting wires

Image: DollaTek JM-101 Fingerprint Sensor Module with multi-colored connecting wires.

  • Czerwony przewód: Power (typically 5V, though the module operates at 3.3V logic).
  • Czarny przewód: Uziemienie (GND).
  • Żółty przewód: RX (Receive data from the sensor, connect to Arduino TX).
  • Biały drut: TX (Transmit data from the sensor, connect to Arduino RX).

Note: Some users report successful operation by connecting the yellow wire to Arduino digital pin 2 and the white wire to Arduino digital pin 3. Always verify with the module's specific datasheet or project requirements. If your Arduino operates at 5V, a logic level shifter may be required for reliable communication on the TX/RX lines.

Connecting to Arduino Uno R3

  1. Połącz Czerwony wire from the sensor to the 5V pin on your Arduino Uno R3.
  2. Połącz Czarny wire from the sensor to a GND pin on your Arduino Uno R3.
  3. Połącz Żółty wire (sensor RX) to a digital pin on your Arduino (e.g., Kołek 2). This pin will act as the Arduino's TX for software serial communication.
  4. Połącz Biały wire (sensor TX) to another digital pin on your Arduino (e.g., Kołek 3). This pin will act as the Arduino's RX for software serial communication.

Konfiguracja oprogramowania

To utilize the fingerprint sensor with your Arduino, you will need to install a compatible library. The Adafruit Fingerprint Sensor Library is a widely used option.

  1. Otwórz środowisko Arduino IDE.
  2. Idź do Sketch > Include Library > Manage Libraries....
  3. In the Library Manager, search for "Adafruit Fingerprint Sensor Library" and install it.
  4. Once installed, explore the example sketches provided with the library (e.g., "enroll" and "fingerprint") to begin enrolling and matching fingerprints.

Instrukcja obsługi

Rejestracja odcisków palców

The enrollment process captures multiple images of a fingerprint to create a robust template for future recognition.

  1. Upload the "enroll" example sketch from the Adafruit Fingerprint Sensor Library to your Arduino.
  2. Open the Serial Monitor in the Arduino IDE (set to the correct baud rate, usually 9600 or 57600 as specified in the sketch).
  3. Follow the on-screen prompts in the Serial Monitor to place your finger on the sensor multiple times. The module will capture and process the images to create a unique fingerprint template.
  4. The enrolled fingerprint will be assigned an ID, which is crucial for later matching.

Fingerprint Matching (Verification - 1:1 Mode)

After enrollment, the module can verify a presented fingerprint against a specific stored template.

  1. Upload the "fingerprint" example sketch (or a custom sketch for 1:1 matching) to your Arduino.
  2. Otwórz Monitor szeregowy.
  3. Place your finger on the sensor. The module will attempt to match the live scan against the stored templates.
  4. The Serial Monitor will display whether a match was found and the corresponding fingerprint ID.

Fingerprint Search (Identification - 1:N Mode)

In 1:N mode, the module searches its entire database of stored fingerprints to find a match for the presented finger.

  1. Ensure multiple fingerprints are enrolled and stored in the module's memory.
  2. Use the appropriate library functions or example sketches designed for 1:N search.
  3. Place a finger on the sensor. The module will scan its entire database to identify the user.
  4. The result will indicate if a match was found and the ID of the matched fingerprint.

Konserwacja

  • Czyszczenie czujnika: Keep the optical sensor surface clean and free from dust, dirt, oils, or moisture. Use a soft, dry, lint-free cloth (e.g., a microfiber cloth) to gently wipe the surface. Avoid abrasive materials or harsh chemicals.
  • Obsługiwanie: Avoid touching the optical sensor surface directly with bare hands to prevent smudges and residue buildup, which can affect performance.
  • Środowisko: Ensure the module is used in a clean, dry environment. If enclosed, provide adequate ventilation to prevent overheating.
  • Znajomości: Periodically check all wiring connections for looseness or damage. Secure any loose connections to ensure stable operation.

Rozwiązywanie problemów

Typowe problemy i rozwiązania

  • Moduł nie odpowiada:
    • Verify the power supply. The module requires DC 3.3V, but can often be powered by 5V from Arduino.
    • Check all wiring connections, especially the TX/RX lines. Ensure the sensor's RX connects to the Arduino's TX, and the sensor's TX connects to the Arduino's RX.
    • Confirm the correct serial port and baud rate are selected in the Arduino IDE's Serial Monitor and in your sketch.
  • Poor recognition rate:
    • Ensure the finger is placed flat and centered on the sensor window.
    • Try enrolling the same finger multiple times (e.g., 2-3 times) to create a more robust template.
    • Wyczyść powierzchnię czujnika zgodnie z opisem w rozdziale Konserwacja.
    • Ensure the finger is not excessively wet or dry during both enrollment and verification.
  • Dioda LED nie świeci:
    • Sprawdź połączenia zasilania modułu.
    • Verify that your code is correctly initializing and interacting with the sensor, including commands to activate the LED.
  • "No finger detected" error:
    • Ensure the finger is firmly pressed against the sensor surface.
    • Check for any physical obstructions on the sensor window.
    • Verify the sensor is properly powered and connected.
  • Błędy komunikacyjne:
    • If using a 5V Arduino, consider using a logic level shifter for the TX/RX lines if experiencing intermittent communication issues, as the sensor operates at 3.3V logic.
    • Double-check baud rate settings in your code and the Serial Monitor to ensure they match.

Product Images and Videos

Zdjęcia produktu

DollaTek JM-101 Optical Blue Light Fingerprint Sensor Module

Image: DollaTek JM-101 Optical Blue Light Fingerprint Sensor Module, front view.

DollaTek JM-101 Fingerprint Sensor Module with connecting wires

Image: DollaTek JM-101 Fingerprint Sensor Module with its multi-colored connecting wires.

Dimensional drawing of the DollaTek JM-101 Fingerprint Sensor Module

Image: Dimensional drawing of the DollaTek JM-101 Fingerprint Sensor Module, showing various measurements.

Tył view of the DollaTek JM-101 Fingerprint Sensor Module showing the PCB

Obraz: Tył view of the DollaTek JM-101 Fingerprint Sensor Module, exposing the printed circuit board (PCB) and connector.

Strona view of the DollaTek JM-101 Fingerprint Sensor Module

Obraz: Bok view of the DollaTek JM-101 Fingerprint Sensor Module, highlighting its profile.

Inna strona view of the DollaTek JM-101 Fingerprint Sensor Module

Obraz: Druga strona view of the DollaTek JM-101 Fingerprint Sensor Module, showing the casinszczegóły g.

Close-up of the connector wires for the DollaTek JM-101 Fingerprint Sensor Module

Image: Close-up of the multi-colored connector wires, showing the white connector end.

Close-up of the female jumper ends of the connecting wires

Image: Close-up of the female jumper ends of the connecting wires, ready for connection to a breadboard or microcontroller pins.

Oficjalne filmy produktowe

Video: Product Display Video. This video demonstrates the general functionality of a fingerprint sensor, showing a similar but not identical model. It illustrates the process of placing a finger and the sensor's response.

Informacje o gwarancji

Proszę zapoznać się z oficjalną instrukcją producenta website or your purchase documentation for detailed warranty information regarding the DollaTek JM-101 Optical Blue Light Fingerprint Sensor Module. Warranty terms and conditions may vary based on region and retailer.

Wsparcie techniczne

For technical assistance, troubleshooting, or further inquiries regarding the DollaTek JM-101 Optical Blue Light Fingerprint Sensor Module, please contact DollaTek customer support. You may also visit their official website for additional resources, FAQs, and community forums.

Powiązane dokumenty - JM-101

Przedview Lista części i schemat zespołu sterowania HR Hydra Rinse
Szczegółowa lista części i ich rozstrzelenie view Schemat zespołu sterowania Hydra Rinse HR, zawierający numery części, opisy, ilości oraz typy produkcji/zakupu. Niniejszy dokument zawiera również historię zmian i ogólne uwagi dotyczące montażu dla rysunku 999-0341.
Przedview Instrukcja instalacji Suprema BioEntry Plus: Kontrola dostępu IP za pomocą odcisku palca
Kompleksowy podręcznik instalacji systemu Suprema BioEntry Plus, szczegółowo opisujący konfigurację, połączenia, środki ostrożności, rozwiązywanie problemów i specyfikacje systemów kontroli dostępu za pomocą odcisków palców opartych na protokole IP.
Przedview Serwomechanizm Jetter JetMove 3000 AmpInstrukcja obsługi lifier
Kompleksowa instrukcja obsługi serwomechanizmu Jetter JetMove 3000 amplifier, obejmujący instalację, konfigurację elektryczną i mechaniczną, diagnostykę, dane techniczne i instrukcje bezpieczeństwa.
Przedview Terminal GNSS SpyGadgets JM-VL03 do pojazdów: zarządzanie flotą i śledzenie
Szczegółowe specyfikacje i funkcje terminala GNSS SpyGadgets JM-VL03 – urządzenia GPS do zarządzania flotą, śledzenia pojazdów i zapewniania bezpieczeństwa. Oferuje łączność LTE/GSM, wejście 9-90 V, analizę stylu jazdy oraz możliwość zdalnego wyłączania.
Przedview Serwomechanizm Jetter JetMove 3000 AmpInstrukcja obsługi lifier — przewodnik instalacji, bezpieczeństwa i techniczny
Kompleksowa instrukcja obsługi serwomechanizmu Jetter JetMove 3000 amplifier. Obejmuje instalację, bezpieczeństwo, diagnostykę, kody zamówień i specyfikacje techniczne automatyki przemysłowej. Dostarczone przez Jetter AG.
Przedview Podesty modułowe TC Bros. Pro Series: Instrukcja montażu i lista części
Szczegółowe informacje na temat modułowych podnośników TC Bros. Pro Series, w tym numery części, dane techniczne i instrukcje montażu dla kierownic o podniesieniu od 6" do 12".