1. Wprowadzenie
This manual provides detailed instructions for the installation, operation, and maintenance of your Keenso MPPT Solar Charge Controller. This device is designed to manage the power flow from your solar panel to your battery bank and DC loads, ensuring efficient charging and protection for your system. Please read this manual thoroughly before installation and use to ensure optimal performance and safety.

Figure 1: Keenso MPPT Solar Charge Controller in a solar power setup.
2. Główne cechy
- Automatyczny system Voltage Identyfikacja: Automatically recognizes 12V or 24V system voltage.
- LCD Display and Dual Button Operation: User-friendly interface for easy monitoring and control.
- Wysokowydajny 3-Stage MPPT Charging: Optimizes battery charging for improved efficiency and lifespan.
- Tryby kontroli obciążenia: Selectable load control modes, including a timer function for night lighting.
- Working Memory Function: Records system run time, error timers, and full battery charge times.
- Kompleksowa ochrona: Includes reliable overvoltage, short-circuit, overload, and reverse connection protection.
- Dokładna kompensacja temperatury: Automatically corrects charging and discharging voltage based on temperature, extending battery life.
- Dwa wyjścia USB: Provides 2.4A x 2 USB ports for charging external devices.
3. Specyfikacje
| Parametr | Wartość |
|---|---|
| Aktualne opcje | 30A, 50A, 70A |
| Znamionowa objętośćtage | 12V / 24V (Auto-identification) |
| Wyjście USB | 2.4A x 2 |
| Nadmierne rozładowanie Voltage | 10.5V - 11V (for 12V system) / 21V - 22V (for 24V system) |
| Kompensacja temperatury | -3mV/°C/ogniwo |
| Wymiary (dł. x szer. x wys.) | 17.5 x 14 x 4 cm (ok. 6.9 x 5.5 x 1.6 cala) |
| Waga | 480 gramów (ok. 1.06 funta) |
| Tworzywo | Plastikowy |
| Typ wyświetlacza | LCD |

Rysunek 2: Wymiary produktu.
4. Instrukcje bezpieczeństwa
Podczas instalacji i obsługi należy przestrzegać następujących środków ostrożności:
- Ensure all connections are correct and secure before powering on the system.
- Connect the battery first, then the solar panel, and finally the DC load. Disconnect in the reverse order.
- Do not connect the solar panel to the controller without a battery connected.
- Zainstaluj kontroler w dobrze wentylowanym pomieszczeniu, z dala od bezpośredniego światła słonecznego, wysokich temperatur i wilgoci.
- Aby zapobiec przegrzaniu i utracie mocy, do wszystkich połączeń należy stosować przewody o odpowiednim przekroju.
- Urządzenie jest przeznaczone wyłącznie do użytku wewnątrz pomieszczeń.
- Przechowywać w miejscu niedostępnym dla dzieci.
5. Konfiguracja i instalacja
5.1 Montaż kontrolera
Mount the solar charge controller vertically on a flat, non-flammable surface. Ensure there is adequate airflow around the unit for proper heat dissipation. Avoid mounting near flammable materials or in areas with excessive dust or moisture.
5.2 połączeń przewodów
Follow the connection order carefully to prevent damage to the controller or other components. Always connect the battery first, then the solar panel, and finally the DC load.
- Podłącz akumulator: Connect the positive and negative terminals of the battery to the corresponding battery terminals on the controller. Ensure correct polarity. The controller will automatically detect the system voltage (12 V lub 24 V).
- Podłącz panel słoneczny: Connect the positive and negative terminals of the solar panel to the corresponding solar panel terminals on the controller. Ensure correct polarity.
- Podłącz obciążenie DC: Podłącz dodatni i ujemny zacisk obciążenia DC do odpowiednich zacisków obciążenia w kontrolerze. Upewnij się, że polaryzacja jest prawidłowa.
Important: Disconnect components in the reverse order: Load, then Solar Panel, then Battery.

Figure 3: Wiring diagram for the solar charge controller.

Rysunek 4: Panel przedni powyżejview with LCD and terminals.
6. Instrukcja obsługi
Wyświetlacz LCD 6.1
The LCD displays various system parameters, including battery voltage, panel słoneczny voltage, load current, charging status, and error codes. Use the dual buttons to navigate through the display menus and adjust settings.
6.2 Funkcje przycisków
The controller features two buttons for operation:
- Lewy przycisk: Used to scroll through display screens and decrease values during setting adjustments.
- Prawy przycisk: Used to enter setting mode, confirm selections, and increase values during setting adjustments.
6.3 Ustawienia kontroli obciążenia
The load output can be configured for different operating modes. Refer to the on-screen menu for options such as 24-hour output, dusk-to-dawn operation, or timed output. To adjust load settings:
- Press and hold the Right button to enter the setting menu.
- Use the Left button to navigate to the load control setting.
- Press the Right button to select the setting, then use the Left/Right buttons to adjust the value.
- Press and hold the Right button again to save and exit the setting menu.
6.4 wyjście USB
The controller provides two USB 2.4A output ports for charging compatible electronic devices such as mobile phones, tablets, and cameras. These ports are active when the controller is powered.

Figure 5: Dual USB ports for device charging.
7. Konserwacja
Regularna konserwacja zapewnia długowieczność i optymalną wydajność regulatora ładowania słonecznego:
- Sprawdź połączenia: Okresowo sprawdzaj wszystkie połączenia przewodów, aby mieć pewność, że są dobrze dokręcone i nie mają śladów korozji.
- Wyczyść kontroler: Utrzymuj kontroler w czystości, bez kurzu i zanieczyszczeń. Do czyszczenia używaj suchej ściereczki. Nie używaj płynów.
- Sprawdź, czy nie ma uszkodzeń: Sprawdź, czy nie ma żadnych uszkodzeń fizycznych casing or wiring.
- Wentylacja: Aby zapewnić właściwe odprowadzanie ciepła, należy upewnić się, że otwory wentylacyjne nie są zablokowane.
8. Rozwiązywanie Problemów
| Problem | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| Kontroler nie włącza się / wyświetlacz LCD jest pusty | Akumulator nie jest podłączony lub jego głośność jest niskatage; podłączenie z odwrotną polaryzacją. | Ensure battery is connected first with correct polarity and has sufficient charge. |
| Bateria się nie ładuje | Solar panel not connected; insufficient sunlight; faulty solar panel/wiring; battery full. | Check solar panel connections and sunlight exposure. Verify solar panel functionality. The controller stops charging when the battery is full. |
| Ładowanie nie działa | Load disconnected; battery voltage too low; overload protection activated; load control setting. | Check load connections. Charge battery. Reduce load. Adjust load control settings. |
| Wyświetlony kod błędu | Specific system fault (e.g., overvoltagnp. zwarcie). | Refer to the controller's display for the specific error code and consult the manufacturer's support for detailed resolution. Address the underlying issue (e.g., disconnect short circuit). |
9. Gwarancja i wsparcie
This Keenso product is covered by a standard manufacturer's warranty. Please refer to your purchase documentation for specific warranty terms and conditions. For technical support, troubleshooting assistance, or warranty claims, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.
For more information about Keenso products, you may visit the official Keenso store: Keenso Store