1. Koniec produktuview
The Walfront SEAFRONT Ultrasonic Water Tank Depth Sensor is designed to monitor the liquid depth level in a tank and display it on a 10-element LCD bar graph. This device also records minimum and maximum liquid levels, supports high/low liquid level alarms, and provides an empty tank alert. It simultaneously displays both indoor and tank temperatures. The receiver unit is versatile, suitable for desktop placement or wall mounting.
Główne cechy:
- Monitors liquid depth level in tanks.
- Displays tank liquid level on a 10-element LCD bar graph.
- Records minimum and maximum tank liquid levels.
- Supports high/low liquid level alarms and liquid empty alerts.
- Displays indoor temperature and tank temperature simultaneously.
- Receiver can be placed on a desk or mounted on a wall.
2. Zawartość opakowania
Before proceeding with installation, please ensure all components are present:
- 1 x Water Level Transmitter
- 1 x odbiornik wewnętrzny
- 2 x Śruby
Notatka: Batteries are not included and must be purchased separately. The receiver requires 2 x 1.5V AA LR3 alkaline batteries, and the transmitter requires 6 x 1.5V AAA LR6 alkaline or lithium batteries.

Rysunek 2.1: Components of the Walfront Water Tank Depth Sensor, including the transmitter, receiver, and mounting screws.
3. Konfiguracja i instalacja
3.1 Instalacja baterii
Install batteries into both the transmitter and receiver units. Ensure correct polarity.
Wideo 3.1: This video demonstrates the process of installing batteries into both the transmitter and receiver units of the Walfront Water Tank Depth Sensor. It shows how to open the battery compartments and insert the batteries correctly.
3.2 Instalacja przetwornika
The transmitter should be installed at the top of your water tank. Ensure the sensor is positioned correctly to accurately measure the liquid level. Refer to the diagram for optimal placement and to avoid common installation errors.

Rysunek 3.1: Detailed setup sketch illustrating the correct installation of the transmitter, including antenna, balance bubble, screws, sensor, and bracket. It also shows examples of incorrect installations to avoid.
3.3 Umiejscowienie odbiornika
Place the receiver unit in a convenient indoor location. It can stand freely on a desk or be mounted on a wall using the provided screws. Ensure it is within the transmission range of 100 meters (300 feet) in an open field from the transmitter.

Rysunek 3.2: The receiver unit displayed in an indoor setting, showing its compact design suitable for desktop placement or wall mounting.
4. Instrukcja obsługi
4.1 Zrozumienie wyświetlacza LCD
The receiver's LCD provides comprehensive information about your tank's liquid level and temperature. Familiarize yourself with the display areas and icons:

Rysunek 4.1: An annotated diagram of the LCD display, highlighting various indicators such as tank level, temperature, time, and alarm status.
- Value Display Area: Shows current tank level and temperatures.
- Tank Temperature and Water Level Icon: Indicates the displayed tank temperature and water level.
- Jednostka poziomu wody: Displays the unit for water level (e.g., meters).
- Tank Temperature Unit (°C/°F): Indicates the unit for tank temperature.
- Outdoor Low Battery Indicator: Alerts when the transmitter's batteries are low.
- Alarm Activation Icon: Shows if an alarm is active.
- Min. and Max. Indicator Icon: Wyświetla się, gdy viewing minimum or maximum records.
- Empty Alert Icon: Indicates an empty tank condition.
- Wskaźnik sygnału RF: Shows the strength of the wireless connection.
- Tank Level High and Low Alarm Indicator: Alerts for high or low liquid levels.
- Water Tank Depth Icon: Represents the water tank and its depth.
- Time Alarm Indicator: Shows if a time alarm is set.
- Time and Alarm Value Area: Displays current time and alarm settings.
- Indoor Temperature Value Display Area: Shows the current indoor temperature.
- Indoor Temperature Unit: Indicates the unit for indoor temperature.
4.2 Setting Alarms and Units
Use the buttons on the receiver to set high/low liquid level alarms, switch temperature units (°C/°F), and view min/max records. Consult the detailed instructions in the full manual for specific button functions and programming steps.

Rysunek 4.2: Close-up of the LCD display and control buttons, including 'set', '+/max/min', '-/tank', and 'alarm' buttons for various functions.
5. Konserwacja
To ensure optimal performance and longevity of your Walfront SEAFRONT sensor, follow these maintenance guidelines:
- Wymiana baterii: Replace batteries in both the transmitter and receiver when the low battery indicator appears. The estimated battery life is a minimum of 12 months for both units.
- Czyszczenie: Periodically clean the exterior of both units with a soft, dry cloth. Do not use abrasive cleaners or immerse the units in water.
- Transmitter Inspection: Annually inspect the transmitter for any signs of wear or damage, especially if exposed to harsh weather conditions. Ensure the sensor area is free from debris or buildup that could obstruct readings.
- Kompatybilność z cieczami: This device is designed for use with non-corrosive liquids only. Using it with corrosive liquids may damage the sensor and void the warranty.
6. Rozwiązywanie Problemów
If you encounter issues with your Walfront SEAFRONT sensor, refer to the following common problems and solutions:
- Brak wyświetlacza na odbiorniku:
- Check if batteries are correctly installed and not depleted. Replace if necessary.
- Ensure the receiver is powered on. - No Liquid Level Reading:
- Verify that the transmitter has fresh batteries and is powered on.
- Check the wireless connection (RF signal indicator on receiver). Move receiver closer to transmitter if signal is weak.
- Ensure the transmitter is installed correctly and the sensor is not obstructed.
- Confirm the liquid in the tank is non-corrosive and within the measurement range (0-15m). - Niedokładne odczyty:
- Re-check transmitter installation according to the diagram in Section 3.2. Incorrect placement can lead to inaccurate measurements.
- Ensure the tank liquid is calm and free from excessive turbulence.
- Verify the sensor is clean and free from any buildup. - Alarmy nie działają:
- Check alarm settings on the receiver to ensure they are correctly configured.
- Verify that the alarm volume is not set to mute or a very low level.
Jeśli po wypróbowaniu tych kroków rozwiązywania problemów problem nadal występuje, skontaktuj się z obsługą klienta.
7. Specyfikacje
| Producent | SEAFRONT |
| Marka | Wallfront |
| Numer modelu przedmiotu | SEAFRONT |
| Tworzywo | Metal Plastik |
| Typ zasilania | Zasilany bateryjnie |
| Tomtage | 1 wolty |
| Zakres temperatury wewnętrznej | 0 ~ 50°C |
| Zakres temperatury zewnętrznej | -40 ~ 60°C |
| Dokładność temperatury | ± 1°C |
| Zakres pomiaru poziomu wody | 0 ~ 15m |
| Rezolucja | 0.01m |
| Częstotliwość transmisji | 433MHz |
| Zasięg transmisji | 100 metrów (300 stóp) w terenie otwartym |
| Akumulator odbiornika | 2 x 1.5V AA LR3 alkaline batteries (not included) |
| Bateria nadajnika | 6 x 1.5V AAA LR6 alkaline or lithium batteries (not included) |
| Rozmiar odbiornika | Wymiary (szer. x wys. x gł.) |
| Rozmiar nadajnika | Wymiary (szer. x wys. x gł.) |
| Rozmiar ekranu LCD | 66 * 45mm (3.3 inch) |
| Suitable Liquid Type | Any non-corrosive liquid |
| UPC | 724942384270 |
8. Gwarancja i wsparcie
This product comes with a standard manufacturer's warranty. For specific warranty details, duration, and terms, please refer to the documentation provided with your purchase or contact the retailer. For technical support, troubleshooting assistance beyond this manual, or inquiries about spare parts, please contact Walfront customer service through their official webmiejscu lub w miejscu zakupu.