YAVIS YAVIS DC12v-60KG

YAVIS 60kg (135lbs) DC 12V Magnetic Electric Lock Instruction Manual

Model: YAVIS DC12v-60KG

1. Koniec produktuview

The YAVIS 60kg (135lbs) DC 12V Magnetic Electric Lock is a robust electromagnetic locking device designed for various access control systems. It provides a secure and efficient solution for controlling door access in commercial and residential environments. This lock operates in a fail-safe mode, meaning it unlocks when power is removed, ensuring safety during power outages. Its durable construction, anti-corrosion properties, and waterproof design make it suitable for a wide range of applications.

2. Informacje dotyczące bezpieczeństwa

  • Ensure all power is disconnected before installation or maintenance to prevent electrical shock.
  • Installation should be performed by qualified personnel or under professional supervision.
  • Sprawdź poprawność objętościtage (DC 12V) and current ratings before connecting the power supply. Incorrect voltage może uszkodzić urządzenie.
  • Do not expose the lock to extreme temperatures or humidity beyond specified operating conditions.
  • This device is designed for security purposes; however, no security system is foolproof. Regular checks are recommended.

3. Zawartość opakowania

Po otrzymaniu przesyłki sprawdź jej zawartość, aby upewnić się, że wszystkie przedmioty są obecne i nieuszkodzone:

  • 1 x YAVIS 60kg (135lbs) Electric Magnetic Lock
  • 1 x Armature Plate
  • 1 x Hexagonal Key
  • 1 x zestaw śrub (do montażu)
  • 1 x Instrukcja obsługi (ten dokument)

4. Specyfikacje techniczne

ModelYAVIS DC12v-60KG
Siła trzymania60 kg (135 funta)
Objętość operacyjnatagePrąd stały 12 V
Prąd roboczy0.11A - 0.15A
Temperatura pracy-20°C do 55°C (-4°F do 131°F)
Wilgotność robocza0% ~ 90% (bez kondensacji)
Czas odblokowania≤ 1 sekunda
Tryb pracyNC (Normally Closed) / Fail-Safe
Lock Body Dimensions (L x W x H)Wymiary: 81 x 42 x 25 mm
Armature Plate Dimensions (L x W x H)Wymiary: 75 x 36 x 10 mm
TworzywoStop aluminium
Cechy specjalneAnti-corrosion, Integrated Voltage Suppressor, Waterproof
Zalecane zastosowaniaWood doors, Glass doors, Metal doors, Fireproof doors, Drawers, Cabinets
Dimensions of the YAVIS 60kg magnetic lock and armature plate

Image 1: Detailed dimensions of the magnetic lock body and its armature plate. The lock body measures 81mm x 42mm x 25mm, and the armature plate measures 75mm x 36mm x 10mm.

5. Konfiguracja i instalacja

The YAVIS magnetic lock is designed for straightforward installation. No specialized tools are typically required beyond basic hand tools. Ensure the mounting surface is clean and secure.

5.1 Montaż zamka

The lock consists of two main parts: the electromagnetic lock body and the armature plate. The lock body is typically mounted on the door frame, and the armature plate is mounted on the door itself, ensuring they align perfectly when the door is closed.

  • Demontaż: The outer shell of the lock body can be disassembled to access mounting holes for anti-theft screws.
  • Umieszczenie: Position the lock body and armature plate to ensure proper alignment and maximum contact surface when the door is closed.
  • Zabezpieczanie: Use the provided screw kit to securely fasten both the lock body to the door frame and the armature plate to the door. Ensure the screws are tightened using the hexagonal key.
Diagram showing the installation of the magnetic lock on a cabinet door

Image 2: Illustration of the magnetic lock installation on a small door or cabinet. The diagram shows the lock body mounted on the frame and the armature plate on the door, with a screw hole fixedly arranged in the casing.

5.2 Schemat okablowania

Refer to the wiring diagram below for connecting the magnetic lock to an access control system. Ensure all connections are secure and correctly polarized.

  • Połącz Czerwony przewód from the magnetic lock to the NC (Normally Closed) terminal of your access controller or power supply.
  • Połącz Czarny drut from the magnetic lock to the COM (Common) terminal of your access controller or power supply.
  • Ważna uwaga: The access controller, power supply, and exit button shown in the diagram are not included with the magnetic lock and must be purchased separately.
Wiring diagram for the YAVIS magnetic lock with an access controller, power supply, and exit button

Image 3: Wiring diagram illustrating how to connect the magnetic lock to an access control system. It shows connections to an access controller, power supply, and an exit button. The red wire connects to NC, and the black wire connects to COM.

Z bliska view of the magnetic lock's internal components and aluminum alloy material

Rysunek 4: Szczegółowy view highlighting the aluminum alloy material and the internal structure of the lock, including the inner six-angle screw design for enhanced security.

Image showing signal feedback function, precision parts, and multiple lock options

Image 5: This image illustrates the signal feedback function for alarm systems, the precision of internal components ensuring stable quality, and mentions multi-options for different holding forces (60KG/180KG/280KG), though this specific model is 60KG.

6. Instrukcja obsługi

The YAVIS magnetic lock operates in a Fail-Safe (NC) mode, which means:

  • Locked State: The lock remains engaged and the door is secured when electrical power (DC 12V) is continuously supplied to the lock.
  • Stan odblokowany: The lock disengages and the door can be opened when the electrical power supply to the lock is interrupted or removed. This is a safety feature, allowing egress during power failures.
  • Integracja: When integrated with an access control system, the lock will be controlled by the system's commands (e.g., card reader, keypad, exit button) to momentarily cut power and unlock the door.

7. Konserwacja

To ensure optimal performance and longevity of your YAVIS magnetic lock, follow these maintenance guidelines:

  • Regularne czyszczenie: Periodically wipe the surfaces of the lock body and armature plate with a soft, dry cloth to remove dust and debris. Avoid abrasive cleaners.
  • Sprawdź połączenia: Annually inspect all electrical wiring and connections for signs of wear, corrosion, or looseness. Ensure they are secure.
  • Kontrola wyrównania: Verify that the lock body and armature plate remain perfectly aligned when the door is closed. Misalignment can reduce holding force and cause premature wear.
  • Antykorozja: The lock features anti-corrosion properties, but avoid exposing it to harsh chemicals or prolonged direct moisture.

8. Rozwiązywanie Problemów

If you encounter issues with your YAVIS magnetic lock, consider the following common troubleshooting steps:

  • Lock Not Engaging (Door Not Securing):
    • Check if the DC 12V power supply is active and correctly connected to the lock.
    • Verify that the red wire is connected to NC and the black wire to COM.
    • Ensure the lock body and armature plate are clean and free of obstructions, allowing full contact.
    • Check for proper alignment between the lock body and armature plate.
  • Lock Not Disengaging (Door Not Opening):
    • Confirm that the access control system is correctly sending the unlock signal (i.e., momentarily cutting power to the lock).
    • Check the wiring for any loose connections or damage that might prevent power interruption.
    • If using an exit button, ensure it is functioning correctly and wired to interrupt power to the lock.
  • Weak Holding Force:
    • Ensure the lock body and armature plate surfaces are clean and free of debris.
    • Check for proper alignment; even slight misalignment can reduce holding force.
    • Verify that the power supply is providing a stable DC 12V and sufficient current (0.11A - 0.15A).

If these steps do not resolve the issue, please contact customer support or a qualified technician.

9. Gwarancja i pomoc techniczna

Specific warranty information for the YAVIS 60kg (135lbs) DC 12V Magnetic Electric Lock is not provided in this manual. Please refer to your purchase documentation or contact your retailer for details regarding warranty coverage.

For technical support, product inquiries, or assistance with installation and troubleshooting beyond the scope of this manual, please contact YAVIS customer service or visit the official YAVIS website. Contact information may be available on the product packaging or your purchase invoice.

© 2023 YAVIS. All rights reserved. Information in this manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.