AUTOOL LM120

Instrukcja obsługi cyfrowego manometru kolektorowego AUTOOL LM120

Model: LM120

1. Wprowadzenie

The AUTOOL LM120 Digital Manifold Gauge is an intelligent electronic instrument designed to assist in the installation, testing, and maintenance of refrigeration equipment. This includes systems such as air conditioners, refrigerators, and cold storage units. It provides precise measurements for pressure, temperature, and vacuum, along with advanced diagnostic capabilities.

AUTOOL LM120 Digital Manifold Gauge with hoses connected to a car's AC system

Image 1.1: AUTOOL LM120 Digital Manifold Gauge in use, connected to an automotive air conditioning system.

2. Informacje dotyczące bezpieczeństwa

Przed użyciem urządzenia należy przeczytać i zrozumieć wszystkie instrukcje bezpieczeństwa. Nieprzestrzeganie tych instrukcji może spowodować obrażenia ciała lub uszkodzenie sprzętu.

  • Always wear appropriate personal protective equipment (PPE), including safety glasses and gloves, when working with refrigeration systems and refrigerants.
  • Ensure adequate ventilation in the work area to prevent the accumulation of refrigerant gases.
  • Do not expose the device to extreme temperatures, direct sunlight, or corrosive environments.
  • Handle refrigerant hoses and connections with care to prevent leaks and accidental discharge.
  • Refer to local regulations and industry standards for the safe handling, recovery, and disposal of refrigerants.
  • Nie należy podejmować prób naprawy ani modyfikacji urządzenia. W celu uzyskania pomocy należy skontaktować się z wykwalifikowanym personelem.

3. Koniec produktuview i komponenty

The LM120 Digital Manifold Gauge features a robust design with an intuitive interface. Familiarize yourself with the components shown below.

Diagram of AUTOOL LM120 Digital Manifold Gauge with numbered components

Image 3.1: Detailed diagram of the LM120 Digital Manifold Gauge components.

  1. Hak
  2. Clamp-on Temperature Probe Socket
  3. Wyświetlacz LCD
  4. Przycisk funkcyjny
  5. Przycisk Uruchom/Zatrzymaj
  6. Przycisk Zero
  7. R+/R- Refrigerant Type Selection Buttons
  8. Przycisk ściemniania
  9. Przycisk jednostki
  10. Przycisk ° C / ° F
  11. Przycisk zasilania
  12. Zawór niskiego ciśnienia
  13. Refrigerant Observation Window
  14. Zawór wysokiego ciśnienia
  15. 1/4 inch Low Pressure Inlet
  16. Zawór bezpieczeństwa
  17. 1/4 inch High Pressure Inlet
  18. Refrigerant Inlet / Vacuum Pump Inlet

4. Konfiguracja

Before first use, ensure the device is ready for operation.

4.1 Pierwsze włączenie zasilania

  • Naciśnij i przytrzymaj Przycisk zasilania (11) to turn on the device.
  • The LCD Display (3) will illuminate and show the initial readings.

4.2 Podłączanie węży

Connect the appropriate refrigeration hoses to the inlets on the manifold gauge.

  • Connect the low-pressure hose to the 1/4 inch Low Pressure Inlet (15).
  • Podłącz wąż wysokociśnieniowy do 1/4 inch High Pressure Inlet (17).
  • Connect the service hose (for vacuum pump or refrigerant tank) to the Refrigerant Inlet / Vacuum Pump Inlet (18).
  • Sprawdź, czy wszystkie połączenia są szczelne, aby zapobiec wyciekom.

4.3 Connecting Temperature Probes (Optional)

For dual temperature measurement, connect compatible clamp-on temperature probes (not included) to the Clamp-on Temperature Probe Socket (2).

5. Instrukcja obsługi

This section details the various functions and how to operate the AUTOOL LM120.

5.1 Wyświetl ponadview

The large LCD provides clear, real-time data for pressure, temperature, and other parameters.

Close-up of the AUTOOL LM120 Digital Manifold Gauge's smart digital display showing pressure and temperature readings

Image 5.1: The smart digital display provides clear readings for various parameters.

5.2 Wybór jednostki

To change pressure or temperature units:

  • Naciśnij Przycisk jednostki (9) to cycle through available pressure units (e.g., Kpa, Psi, Bar).
  • Naciśnij Przycisk ° C / ° F (10) to switch between Celsius and Fahrenheit temperature displays.

5.3 Refrigerant Type Setting

The device has a built-in database of 89 refrigerants. Select the correct refrigerant type for accurate calculations.

AUTOOL LM120 Digital Manifold Gauge showing refrigerant type R11 on its display

Image 5.2: Setting the refrigerant type on the LM120 display.

  • Użyj R+/R- Refrigerant Type Selection Buttons (7) to scroll through the available refrigerant types.
  • Potwierdź swój wybór.

5.4 Pomiar ciśnienia

The LM120 measures both high and low pressures simultaneously.

  • Ensure hoses are correctly connected to the high and low-pressure ports of the system.
  • The display will show the current high and low pressure readings.

5.5 Pomiar temperatury

With optional clamp-on temperature probes, the device can measure dual temperatures.

AUTOOL LM120 Digital Manifold Gauge displaying T1 Sensor and T2 Sensor temperatures

Image 5.3: High/Low pressure temperature test display.

  • Attach the temperature probes to the desired measurement points (e.g., suction line, liquid line).
  • The display will show T1 and T2 temperature readings.

5.6 Evaporation Pressure & Temperature Test

This function measures the maximum pressure when the refrigerant changes from liquid to gas and the lowest temperature when the liquid becomes gaseous.

AUTOOL LM120 Digital Manifold Gauge displaying evaporation pressure and temperature test results

Image 5.4: Evaporation pressure and temperature test results on the display.

5.7 Condensing Pressure & Temperature Test

This function measures the minimum pressure when the refrigerant changes from gas to liquid and the maximum temperature when the gas changes to liquid.

AUTOOL LM120 Digital Manifold Gauge displaying condensing pressure and temperature test results

Image 5.5: Condensing pressure and temperature test results on the display.

5.8 Pressure Leakage Test

The device can perform a pressure leakage test, recording leak time and speed.

AUTOOL LM120 Digital Manifold Gauge displaying pressure leakage test results with time and pressure values

Image 5.6: Pressure leakage test in progress, showing initial and current pressure values over time.

  • Connect the gauge to the system to be tested.
  • Naciśnij Przycisk funkcyjny (4) to navigate to the leakage test mode.
  • Follow the on-screen prompts to start and monitor the test. The device calculates the pressure difference between the initial and second test pressures to determine if refrigerant is leaking.

5.9 Pomiar próżni

The LM120 can measure the percentage of vacuum achieved in a system.

  • Connect the vacuum pump to the Refrigerant Inlet / Vacuum Pump Inlet (18).
  • Activate the vacuum pump and monitor the vacuum percentage na wyświetlaczu.

5.10 Superheat and Subcooling Calculation

Leveraging its integrated 89-type refrigerant database, the LM120 can automatically calculate superheat and subcooling temperatures.

Table showing 89 types of refrigerant data built into the LM120 Digital Manifold Gauge

Image 5.7: Built-in database of 89 refrigerant types for accurate calculations.

  • Ensure the correct refrigerant type is selected (refer to Section 5.3).
  • With pressure and temperature probes connected, the device will display calculated superheat and subcooling values.

6. Konserwacja

Proper maintenance ensures the longevity and accuracy of your LM120 Digital Manifold Gauge.

  • Czyszczenie: Przetrzyj urządzenie miękką, suchą ściereczką. Nie używaj środków czyszczących o właściwościach ściernych ani rozpuszczalników.
  • Składowanie: Store the gauge in its original case or a protective container in a cool, dry place away from direct sunlight and extreme temperatures.
  • Kontrola węża: Regularly inspect refrigerant hoses for cracks, wear, or damage. Replace damaged hoses immediately.
  • Kontrola połączenia: Ensure all connections and valves are clean and free of debris.

7. Rozwiązywanie Problemów

If you encounter issues with your LM120, refer to the following common problems and solutions.

ProblemMożliwa przyczynaRozwiązanie
Urządzenie nie włącza sięLow or depleted internal battery; power button not pressed correctly.Ensure the device is charged or has sufficient power. Press and hold the Power Button firmly.
Niedokładne odczyty ciśnienia/temperaturyIncorrect refrigerant selected; loose hose connections; faulty probes; sensor calibration needed.Verify the correct refrigerant type. Check all hose connections for tightness. Ensure temperature probes are clean and properly connected. Perform a zero calibration if available (using Zero Button).
Wyświetlacz jest słaby lub nieczytelnyPodświetlenie wyłączone, bateria słaba.Press the Dimming Button (8) to adjust backlight. Ensure the device is charged.
Leakage test shows false positive/negativeImproper connection; external temperature fluctuations; insufficient test duration.Ensure all connections are absolutely leak-free. Conduct the test in a stable environment. Allow sufficient time for the test to complete.

8. Specyfikacje

Detailed technical specifications for the AUTOOL LM120 Digital Manifold Gauge.

FunkcjaSpecyfikacja
ProducentAUTOOL
Numer modeluLM120
TworzywoHigh-strength Engineering Plastic
Zakres testu ciśnieniowego0 kpa – 6000 kpa
Rozdzielczość testu ciśnieniowego1 kPa
Dokładność testu ciśnieniowego+/- 0.5 %(FS) + 5dgt
Limit przeciążenia ciśnieniowego10000 Kpa (10 Mpa; 100 bar)
Number of Refrigerants in Database89 typów
Standardowy interfejs1/4 cala
Wymiary (dł. x szer. x wys.)20.32 x 7.62 x 12.7 cm (8 x 3 x 5 cala)
Waga59.53 g (2.1 uncji)
Zawiera elementy1 set of LM120 Digital Refrigeration Manifold Gauge
Wymagane baterieNo (implies internal rechargeable or power source)
UPC733810026709, 733810026198

9. Gwarancja i wsparcie

AUTOOL is committed to providing high-quality products and customer satisfaction.

  • Trzyletnia gwarancja: For damage caused by non-human factors, AUTOOL promises to resend parts free of charge within 3 years from the date of purchase.
  • Permanent Maintenance: The product is covered by permanent maintenance support.
  • Obsługa klienta: For any inquiries, technical assistance, or warranty claims, please contact AUTOOL customer support. You can expect a response within 24 hours.

© 2024 AUTOOL. Wszelkie prawa zastrzeżone.

Powiązane dokumenty - LM120

Przedview Instrukcja obsługi cyfrowego manometru kolektorowego AUTOOL LM120/LM120+
Niniejsza instrukcja obsługi zawiera kompleksowe wskazówki dotyczące cyfrowego manometru do kolektora AUTOOL LM120/LM120+. Zawiera szczegółowe informacje na temat specyfikacji produktu, jego konstrukcji, instrukcji dotyczących napełniania czynnikiem chłodniczym, pracy w podciśnieniu oraz testowania szczelności. Zawiera również opisy typowych problemów, słownik terminów, porady dotyczące konserwacji, informacje gwarancyjne oraz procedury zwrotu/wymiany. Niezbędna dla techników HVAC i specjalistów ds. chłodnictwa.
Przedview AUTOOL LM120+ Instrukcja obsługi cyfrowego miernika kolektora
Kompleksowa instrukcja obsługi cyfrowego manometru rozdzielczego AUTOOL LM120+, szczegółowo opisująca jego funkcje, dane techniczne, środki ostrożności, instrukcje obsługi i wskazówki dotyczące rozwiązywania problemów w systemach chłodniczych i HVAC.
Przedview Instrukcja obsługi cyfrowego testera ciśnienia w kolektorze AUTOOL LM150 — narzędzie do pomiaru czynnika chłodniczego HVAC
Kompleksowa instrukcja obsługi cyfrowego testera ciśnienia w kolektorze AUTOOL LM150. Zawiera specyfikację produktu, instrukcje obsługi dotyczące napełniania czynnikiem chłodniczym, próżni i testowania szczelności, typowe problemy, słowniczek terminów, informacje o konserwacji, gwarancji oraz zasady zwrotów dla specjalistów z branży HVAC i chłodnictwa.
Przedview AUTOOL Im 120 Cyfrowy manometr kolektorowy Instrukcja obsługi
Kompleksowa instrukcja obsługi cyfrowego manometru AUTOOL Im 120, szczegółowo opisująca jego funkcje, dane techniczne, instrukcje dotyczące napełniania czynnikiem chłodniczym, testowania próżniowego, wykrywania nieszczelności, środki ostrożności, typowe problemy i słownik pojęć dotyczących układów chłodniczych.
Przedview Instrukcja obsługi cyfrowego manometru kolektorowego AUTOOL LM120/LM120+
Instrukcja obsługi cyfrowego manometru rozdzielczego AUTOOL LM120/LM120+ zawierająca szczegółowe informacje na temat jego funkcji, wytycznych dotyczących bezpieczeństwa, specyfikacji i procedur operacyjnych dotyczących instalacji, testowania i konserwacji systemu HVAC.
Przedview Instrukcja obsługi zestawu inteligentnego kolektora cyfrowego AUTOOL LM160
Kompleksowa instrukcja obsługi zestawu inteligentnego rozdzielacza cyfrowego AUTOOL LM160, obejmująca kwestie obsługi, dane techniczne, konserwację i bezpieczeństwo w zastosowaniach HVAC.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.