Wstęp
The Elitech PG-30Pro Digital Pressure Gauge is designed for precise real-time pressure measurement in various systems, including pipeline and refrigeration applications. It features a clear backlight display, automatic shutdown, low battery indication, and an over-pressure warning light for enhanced safety and usability. Its robust design and long battery life make it a reliable tool for professionals.
This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your PG-30Pro Digital Pressure Gauge. Please read it thoroughly before use.
Cechy produktu
- Wyświetlacz z podświetleniem: Zapewnia wyraźną widoczność odczytów w różnych warunkach oświetleniowych.
- Max/Min Value Display and Reset: Records maximum and minimum pressure values, with an option to reset for new data collection.
- Funkcja zerowania: Allows for calibration to correct any deviation at the zero point.
- Szeroka kompatybilność z czynnikami chłodniczymi: Supports over 90 common refrigerants, making it versatile for various AC and refrigeration systems.
- Auto Shut-Off Setting: Oszczędza baterię, automatycznie wyłączając urządzenie po określonym czasie bezczynności.
- Adjustable Temperature and Pressure Units: Users can select preferred units for both temperature and pressure measurements.
- Wskaźnik niskiego poziomu baterii: Displays "LOB" when battery power is low.
- Over-Pressure Warning: Alerts the user to potentially damaging pressure levels.

Image: Elitech PG-30Pro Digital Pressure Gauge showcasing its main features including backlight, Max/Min display, zeroing function, refrigerant compatibility, auto shut-off, and adjustable units.
Organizować coś
1. Instalacja baterii
- Znajdź pokrywę komory baterii z tyłu urządzenia.
- Open the cover and insert three (3) AAA batteries, ensuring correct polarity (+/-).
- Dokładnie zamknij pokrywę komory baterii.
2. Connecting the Gauge
- The PG-30Pro is equipped with a standard 1/8-inch NPT fitting.
- Ensure the system you are connecting to is compatible with this fitting size.
- Carefully thread the gauge onto the system's pressure port. Do not overtighten.
- Verify a secure, leak-free connection before proceeding with measurements.

Image: The Elitech PG-30Pro Digital Pressure Gauge illustrating its 1/8-inch NPT fitting and overall dimensions for connection reference.
Instrukcja obsługi
1. Włączanie/wyłączanie zasilania
Naciśnij MOC button (usually marked with a circle and vertical line) to turn the device on. Press and hold the MOC przycisk, aby go wyłączyć.
2. Wybór jednostki
Naciśnij USTAWIĆ button to cycle through available pressure units (MPa, kPa, bar, psi, kg/cm²) and temperature units (°C, °F). Select the desired units for your measurement.

Image: The Elitech PG-30Pro Digital Pressure Gauge showing its display with adjustable temperature and pressure units, such as psi and °C/°F.

Image: A close-up of the Elitech PG-30Pro Digital Pressure Gauge's LCD display with its blue backlight activated, showing pressure and temperature readings.
3. Zeroing Function
Before taking a measurement, especially in a new environment or after a long period of storage, it is recommended to zero the gauge. With no pressure applied, press the ZERO button to reset the reading to zero. This corrects any potential deviation and ensures accurate measurements.
4. Max/Min Value Recording
The gauge automatically records the maximum and minimum pressure values during operation. To view these values, press the USTAWIĆ button repeatedly until "MAX" or "MIN" appears on the display. To clear these recorded values and start a new recording cycle, press and hold the ZERO przycisk, gdy viewing the MAX/MIN display.

Image: The Elitech PG-30Pro Digital Pressure Gauge highlighting the Power and Zero buttons, used for Max/Min value display and reset.
5. Refrigerant Selection (PT Table)
The PG-30Pro has a built-in pressure-temperature (PT) comparison table for over 90 common refrigerants. This allows for convenient reference during HVAC and refrigeration system work. Consult the device's specific menu or accompanying documentation for how to access and utilize this feature.

Image: The Elitech PG-30Pro Digital Pressure Gauge demonstrating its compatibility with a wide range of refrigerants, including R12, R22, R134a, R401A, and others.
Konserwacja
- Czyszczenie: Przetrzyj urządzenie miękką, damp ściereczka. Nie należy używać środków czyszczących o właściwościach ściernych ani rozpuszczalników.
- Składowanie: Store the gauge in a dry, cool place away from direct sunlight and extreme temperatures. If storing for extended periods, remove the batteries to prevent leakage.
- Wymiana baterii: Replace batteries when the "LOB" indicator appears on the display. Ensure to use three (3) new AAA batteries.
- Kontrola: Regularly inspect the pressure port and fitting for any signs of damage or wear. Replace if necessary to ensure accurate and safe operation.
Rozwiązywanie problemów
| Problem | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| Urządzenie nie włącza się. | Rozładowane lub nieprawidłowo zainstalowane baterie. | Sprawdź biegunowość baterii. Wymień baterie na nowe baterie AAA. |
| Niedokładne odczyty. | Gauge not zeroed; faulty connection; sensor issue. | Perform zeroing function. Check for leaks at the connection. If problem persists, contact support. |
| "LOB" displayed. | Niski poziom naładowania baterii. | Natychmiast wymień baterie. |
| Wyświetlacz jest przyciemniony lub migocze. | Low battery power; environmental conditions. | Replace batteries. Ensure operating within specified temperature range. |
Specyfikacje
| Parametr | Wartość |
|---|---|
| Model | PG-30Pro |
| Zakres pomiaru ciśnienia | -0.100 to 5.515 MPa (0 to 800 psi) |
| Temperatura pracy | 10°C do 60°C (50°F do 140°F) |
| Wilgotność robocza | Wilgotność względna od 35% do 85% |
| Rezolucja | 0.001 MPa, 0.1 psi |
| Dokładność | ±0.5% FS (pełna skala) |
| Jednostki temperatury | ° C / ° F |
| Żywotność baterii | Do 1 roku |
| Zasilacz | 3 baterie AAA |
| SampOkres | 1 sekunda |
| Wyświetlacz | 1.9 x 1 inch LCD with Blue Backlight |
| Jednostki miary | MPa, kPa, bar, psi, kg/cm², cmHg |
| Dopasowywanie | 1/8 cala NPT |
| Wymiary produktu (dł. x szer. x wys.) | 45 × 45 × 197 mm (1.77 × 1.77 × 7.76 cala) |
| Waga produktu | 248 g (8.78 uncji) |
| Tworzywo | Plastikowy |
| Kompatybilność z czynnikiem chłodniczym | Ponad 90 typy |

Obraz: Byłyamples of the Elitech PG-30Pro Digital Pressure Gauge in use across various applications, including automotive AC maintenance, residential AC installation, cold storage temperature control, commercial refrigeration inspection, heat pump system pressure testing, and refrigerant recovery and charging.
Gwarancja i wsparcie
For warranty information, technical support, or service inquiries, please contact Elitech customer service. Refer to the product packaging or Elitech's official webna naszej stronie znajdziesz najnowsze dane kontaktowe.
Webstrona: www.elitech.com
Please have your product model (PG-30Pro) and purchase date available when contacting support.