1. Wprowadzenie

This manual provides instructions for the installation, operation, and maintenance of the Georgia-Pacific enMotion 10" Automated Touchless Paper Towel Dispenser, Model 59460A. This dispenser is designed for hygienic, reliable, and efficient paper towel dispensing in various commercial environments.

Główne cechy:

Georgia-Pacific enMotion 10 inch Automated Touchless Paper Towel Dispenser, Gray

Rycina 1: Przód view of the enMotion 10" Automated Touchless Paper Towel Dispenser in Gray.

Wewnętrzny view of enMotion dispenser showing jam-free engineering and quiet operation

Figure 2: Internal components highlighting the jam-free design and quiet operation features.

2. Konfiguracja i instalacja

2.1 Rozpakowywanie zawartości

Carefully remove the dispenser from its packaging. Verify that all components are present:

Note: Mounting screws are not included and must be supplied by the installer.

enMotion dispenser with key kit, reference guide, and 4 D-cell batteries

Figure 3: Included accessories: key kit, reference guide, and 4 D-cell batteries.

2.2 Instalacja baterii

  1. Open the dispenser cover using the provided key.
  2. Zlokalizuj komorę baterii.
  3. Insert the 4 D-cell batteries, ensuring correct polarity (+/-).
  4. Dokładnie zamknij komorę baterii.

2.3 Mounting the Dispenser

The dispenser is designed for wall mounting. Choose a suitable location, considering accessibility and clearance for paper towel dispensing.

  1. Mark the desired mounting points on the wall. Refer to the reference guide for specific mounting hole locations.
  2. W razie potrzeby wywierć otwory pilotażowe.
  3. Secure the dispenser to the wall using appropriate screws (not included).
enMotion dispenser mounted on a wall

Figure 4: The enMotion dispenser securely mounted on a wall.

2.4 Loading Paper Towel Rolls

This dispenser is compatible with enMotion 10" paper towel refills (e.g., 89460, 89470, 89480, 89485, 89490).

  1. Otwórz pokrywę dozownika.
  2. Place the paper towel roll onto the internal spindle, ensuring it is properly seated.
  3. Feed the leading edge of the paper towel into the dispensing mechanism as indicated by internal guides.
  4. Close the dispenser cover until it latches securely.
Diagram showing compatible enMotion 10 inch paper towel dispensers and refills

Rysunek 5: Koniecview of compatible enMotion 10" paper towel rolls and other dispenser models.

3. Instrukcja obsługi

3.1 Dozowanie ręczników papierowych

The enMotion dispenser operates automatically. Simply place your hand in the sensor area below the dispenser opening. The dispenser will detect your hand and automatically present a sheet of paper towel.

3.2 Dostosowywanie ustawień

The dispenser features internal controls to customize dispensing settings, such as sheet length and delay between dispenses. These settings can help optimize paper usage and reduce waste.

  1. Otwórz pokrywę dozownika za pomocą klucza.
  2. Locate the control panel inside the dispenser.
  3. Refer to the reference guide for detailed instructions on adjusting specific settings. Common adjustments include:
    • Sheet Length: Adjusts the length of the dispensed paper towel.
    • Czułość czujnika: Modifies how easily the dispenser detects a hand.
    • Czas opóźnienia: Sets the time before another sheet can be dispensed after the previous one.
  4. After making adjustments, close the dispenser cover securely.
Close-up of the enMotion dispenser's internal control panel with buttons for settings

Figure 6: Internal control panel for adjusting dispenser settings.

4. Konserwacja

4.1 Czyszczenie

To maintain hygiene and optimal performance, clean the dispenser regularly.

  1. Otwórz pokrywę dozownika.
  2. Przetrzyj powierzchnię zewnętrzną i wewnętrzną miękką szmatką.amp szmatką i łagodnym, nieściernym środkiem czyszczącym.
  3. Ensure the sensor area is free from dust and debris.
  4. Do not use harsh chemicals or abrasive materials, as these can damage the dispenser's finish.
  5. Close the dispenser cover securely after cleaning.

4.2 Wymiana baterii

When the batteries are low, the dispenser may indicate this with a light or reduced performance. Replace all four D-cell batteries simultaneously to ensure consistent power.

  1. Otwórz pokrywę dozownika.
  2. Wyjmij stare baterie z komory.
  3. Włóż nowe baterie typu D, zwracając uwagę na prawidłową biegunowość.
  4. Zamknij komorę baterii i pokrywę dozownika.

5. Rozwiązywanie Problemów

ProblemMożliwa przyczynaRozwiązanie
Dispenser not dispensing paper.Niski poziom naładowania baterii lub jej rozładowanie.
Paper roll empty or improperly loaded.
Czujnik jest zasłonięty.
Wymień baterie.
Load a new paper roll correctly.
Oczyść obszar czujnika.
Paper jams frequently.Incorrect paper type.
Paper improperly loaded.
Przeszkoda mechanizmu wewnętrznego.
Ensure use of compatible enMotion 10" rolls.
Reload paper roll according to instructions.
Inspect for debris and clear any obstructions.
Dozownik jest głośny.Unusual operation.Verify paper is loaded correctly. If noise persists, contact support.
Paper towel length is inconsistent.Settings require adjustment.Refer to Section 3.2 for adjusting dispensing settings.

6. Specyfikacje

FunkcjaSzczegół
Numer modelu59460A
MarkaGeorgia-Pacyfik
KolorSzary
Typ montażuMontaż ścienny
Wymiary produktu (dł. x szer. x wys.)15.06" dł. x 10.06" szer. x 17.3" wys. (w przybliżeniu)
Waga przedmiotu11.48 funta
Wymagane baterieYes (4 D-cell batteries)
Compatible Paper Towel RollsenMotion 10" Paper Towel Rolls (e.g., 89460, 89470, 89480, 89485, 89490)
Diagram showing dimensions of the enMotion dispenser: 17.3 inches H, 9.5 inches D, 14.7 inches W

Figure 7: Dispenser dimensions for planning installation.

7. Informacje o gwarancji

This product is typically available via a one-time, lifetime lease agreement with GP PRO or an authorized distributor. For specific warranty terms and conditions, please refer to your lease agreement or contact Georgia-Pacific directly.

8. Obsługa klienta

For further assistance, technical support, or to inquire about replacement parts, please contact Georgia-Pacific customer service or your authorized distributor.