DROK 300482_JPN

DROK Adjustable Current Voltage Analog Simulator Signal Generator

Model: 300482_JPN

1. Wprowadzenie

This manual provides comprehensive instructions for the DROK Adjustable Current Voltage Analog Simulator Signal Generator, Model 300482_JPN. This versatile module is designed to generate both 0/4-20mA current signals and 0-10V voltage signals, making it suitable for a wide range of industrial and testing applications. Please read this manual carefully before operation to ensure proper use and to prevent damage.

DROK Signal Generator top-down view

Obraz 1: Widok z góry na dół view of the DROK Signal Generator, showing the digital display, control knob, and terminal block.

2. Specyfikacje

ParametrWartość
Objętość operacyjnatageDC 12-24V
Sygnał wejściowyPotentiometer (for adjustment)
Sygnał wyjściowy0/4-20mA (Current) or 0-10V (Voltage)
Current Display Accuracy0.1mA
Tomtage Dokładność wyświetlania0.01 V
Wymiary (dł. x szer. x wys.)100mm x 68mm x 38mm
Waga produktu130g
Numer części producenta300482_JPN
DROK Signal Generator dimensions

Image 2: Dimensions of the DROK Signal Generator, illustrating its compact size.

3. Funkcje produktu

  • Podwójne wyjście sygnału: Generates both 0/4-20mA current signals and 0-10V voltage signals from a single module.
  • Regulowane wyjście: Output signals are precisely adjustable using a multi-cycle potentiometer.
  • Przejrzysty wyświetlacz LED: Features a bright, clear 3-digit LED digital display for real-time monitoring of output current and voltage.
  • Easy Display Switching: A dedicated switch allows for quick toggling between current and voltagtryby wyświetlania.
  • Kalibracja wyświetlacza: Includes calibration potentiometers on the module's rear for fine-tuning the current and voltage display accuracy.
  • Szerokie zastosowanie: Suitable for signal generation, valve adjustment, inverter control, PLC debugging, panel debugging, LED testing, and transmitter output simulation.

4. Konfiguracja

Before operating the signal generator, ensure proper power supply connection and output wiring.

  1. Podłączenie zasilania: Connect a DC 12-24V power source to the designated power input terminals (typically labeled '24V' and 'GND' or similar) on the terminal block. Ensure correct polarity.
  2. Okablowanie wyjściowe: Connect your target device or multimeter to the appropriate output terminals. For current output, use the '0-20mA' terminals. For voltage output, use the '0-10V' terminals. Refer to the terminal block labels for precise connections.
DROK Signal Generator with power and output labels

Obraz 3: Tył view of the DROK Signal Generator, showing the power supply and output voltage/current labels.

5. Działanie

The signal generator features a main control knob and a display switch for easy operation.

  1. Włączanie: Once connected to a DC 12-24V power supply, the LED display will illuminate.
  2. Select Output Type: Use the slide switch (labeled SW1 or similar) to select between voltage output (0-10V) or current output (0/4-20mA). The switch position will typically be indicated by labels such as '10V' for voltage and '20mA' for current.
  3. Adjust Output Value: Rotate the multi-cycle potentiometer knob (labeled 'Min' to 'Max') to adjust the desired output signal. Turning the knob clockwise increases the output, and counter-clockwise decreases it.
  4. Przełącz tryb wyświetlania: Press the button located below the LED display to toggle between displaying the output current and output voltage.
DROK Signal Generator control layout

Image 4: Labeled diagram of the control panel. It shows the 3-digit digital display, the current/voltage display switch (left for voltage, right for current), and the multi-cycle adjustable potentiometer.

6. Display Calibration

The module includes calibration potentiometers on the back to ensure the displayed values match the actual output. A multimeter is required for accurate calibration.

DROK Signal Generator PCB with calibration potentiometers

Obraz 5: Spód view of the DROK Signal Generator PCB, highlighting the two blue calibration potentiometers for current and voltage display adjustment.

6.1. Current Display Calibration

  1. Rotate the main multi-cycle potentiometer knob clockwise to its maximum output.
  2. Set the output type switch (SW1) to the current output position (e.g., '20mA').
  3. Use an external multimeter to measure the actual output current value from the '0-20mA' terminals.
  4. Adjust the current display adjustment potentiometer (located on the back of the module, refer to Image 5) until the value shown on the module's LED display matches the actual current value measured by the multimeter.

6.2. Tomtage Display Calibration

  1. Rotate the main multi-cycle potentiometer knob clockwise to its maximum output.
  2. Set the output type switch (SW1) to the voltage output position (e.g., '10V').
  3. Use an external multimeter to measure the actual output voltage value from the '0-10V' terminals.
  4. Dostosuj głośnośćtage display adjustment potentiometer (located on the back of the module, refer to Image 5) until the value shown on the module's LED display matches the actual voltage value measured by the multimeter.

7. Aplikacje

The DROK Signal Generator is suitable for various applications, including but not limited to:

  • General signal generation for testing and development.
  • Valve adjustment and control.
  • Inverter control systems.
  • PLC (Programmable Logic Controller) debugging.
  • Panel debugging and testing.
  • LED testing and characterization.
  • Transmitter output simulation.

8. Rozwiązywanie Problemów

ProblemMożliwa przyczynaRozwiązanie
Brak wyświetlacza/brak zasilaniaNiewłaściwe napięcie zasilaniatage or polarity; Loose connection.Verify DC 12-24V power supply. Check power cable connections and polarity.
Output value does not changePotentiometer not adjusted; Output type switch in wrong position.Rotate the main potentiometer. Ensure the output type switch (SW1) is set correctly for current or voltage.
Displayed value is inaccurateDisplay requires calibration.Perform display calibration as described in Section 6 using an external multimeter.
Brak sygnału wyjściowegoIncorrect wiring; Faulty connection to target device.Check output wiring to the target device. Ensure the device is correctly configured to receive the signal.

9. Zawartość opakowania

The package for Model 300482_JPN typically includes:

  • 1 x DROK Adjustable Current Voltage Analog Simulator Signal Generator

10. Gwarancja i wsparcie

For warranty information or technical support, please refer to the product's purchase platform or contact DROK customer service directly. Keep your purchase receipt for warranty claims.

© 2024 DROK. All rights reserved.

Powiązane dokumenty - 300482_JPN

Przedview Generator sygnału DROK 4-20 mA (model 300425) – specyfikacja i przewodnik kalibracji
Szczegółowe specyfikacje i instrukcje kalibracji generatora sygnałowego DROK 4-20 mA, model 300425. Dowiedz się więcej o jego zasilaniu, wyświetlaczu LED, prądzie wyjściowym i procesie kalibracji krok po kroku.
Przedview ZQSIG-800E Portable Signal Generator User Manual
Comprehensive user manual for the ZQSIG-800E Portable Signal Generator. Includes operating instructions, wiring diagrams, signal output/measurement guides, and troubleshooting for voltage, current, thermocouple, and RTD signals.
Przedview Gaqqee QH-VISG2 VoltagInstrukcja obsługi generatora sygnału prądowego i e
Comprehensive user manual for the Gaqqee QH-VISG2-ED and QH-VISG2-EN signal generator. Includes technical specifications, wiring diagrams, parameter settings, and troubleshooting guide.
Przedview Instrukcja obsługi wielofunkcyjnego generatora sygnałowego FNIRSI SG-003A
Kompleksowa instrukcja obsługi wielofunkcyjnego generatora sygnałowego FNIRSI SG-003A, obejmująca instrukcje bezpieczeństwa, specyfikację produktu, panel przycisków, opisy wyświetlacza i sygnałów, rozszerzenia, okablowanie, rozwiązywanie usterek, konserwację i aktualizację oprogramowania sprzętowego.
Przedview FNIRSI SG-003A 信号发生器 用户手册
FNIRSI SG-003A 信号发生器用户手册。本指南详细介绍了 SG-003A 信号发生器的操作方法、功能特性、技术参数、接线指南、故障排除及固件升级等内容,帮助用户全面掌握设备使用。
Przedview Aideepen VoltagInstrukcja obsługi generatora sygnału prądowego i e
Comprehensive user manual for the Aideepen handheld digital voltage and current signal generator. Includes technical specifications, wiring diagrams, operation instructions, parameter settings, and troubleshooting guide.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.