SPECTRA MM012340-24mm
Instrukcja obsługi zestawu akcesoriów do laktatora Spectra Premium
Model: MM012340-24mm
1. Koniec produktuview
The Spectra Premium Breast Milk Pump Accessory Kit provides essential components for your Spectra electric breast pump, ensuring optimal performance and hygiene. This kit is designed to be compatible with various Spectra pump models and is made from high-quality, safe materials.

Image: All components of the Spectra Premium Breast Milk Pump Accessory Kit, including a breast flange, milk bottle, backflow protector, duckbill valve, and tubing.
Zawartość zestawu:

Image: A visual breakdown of the kit's contents, indicating one 24mm breast flange, one wide neck milk bottle, one backflow protector, one duckbill valve, and tubing.
- 1 x 24mm Breast Flange
- 1 x Wide Neck Milk Bottle
- 1 x Backflow Protector
- 1 x Duckbill Valve
- 1 x rura
Główne cechy:

Image: An infographic detailing the kit's optimal performance for proper pumping function, compatibility with S1 Plus, S2 Plus, and 9 Plus breast pumps, and its BPA and DEHP-free materials.
- Optymalna wydajność: Designed to maintain proper pumping function.
- BPA/DEHP Free: All parts that come in contact with breast milk are made from materials free of BPA and DEHP, ensuring safety.
- Zgodność: This kit is compatible with Spectra S1, S2, 9 Plus, and Synergy Gold electric breast pumps.
Film o produkcieview:
Video: An official Spectra product video providing an overview of Spectra breast pumps and accessories, highlighting features such as hospital strength, closed system design, Natural Nursing Technology, and hands-free pumping options. This video demonstrates the general use and benefits of Spectra products, including the type of accessories found in this kit.
2. Instalacja i montaż
Proper assembly of your Spectra accessory kit is crucial for effective and hygienic pumping. Follow these steps to set up your kit before each use.

Image: A user demonstrating the assembly of the breast pump parts, connecting the tubing to the breast flange assembly and bottle.
- Czyszczenie i dezynfekcja: Before first use and after each subsequent use, thoroughly clean and sanitize all parts that come into contact with breast milk (breast flange, milk bottle, backflow protector, duckbill valve). Refer to the "Cleaning & Maintenance" section for detailed instructions.
- Assemble Backflow Protector: Ensure the silicone diaphragm is securely seated within the plastic casing of the backflow protector.
- Zamontuj zawór typu „kaczy dziób”: Firmly insert the duckbill valve into the bottom of the breast flange.
- Podłącz butelkę: Screw the milk bottle onto the bottom of the breast flange assembly.
- Podłącz rurkę: Connect one end of the tubing to the top of the backflow protector and the other end to the port on your Spectra breast pump.
- Wymiary kołnierza: Ensure you are using the correct flange size for your nipple. An improperly sized flange can lead to discomfort and reduced milk output. Refer to the image below for guidance on proper flange fit.

Image: A visual guide showing examples of a breast flange that is too large, too small, and a great fit for the nipple, emphasizing the importance of proper sizing for comfort and efficiency.
3. Działanie
Once assembled, the accessory kit is ready for use with your Spectra electric breast pump. Follow your breast pump's specific operating instructions for power on, mode selection, and suction level adjustments.
- Ensure all connections are secure before starting the pump.
- Position the breast flange correctly on your breast, ensuring your nipple is centered.
- Begin pumping at a comfortable suction level and adjust as needed.
- For double pumping, you will need two accessory kits.
4. Czyszczenie i konserwacja
Regular cleaning and proper maintenance are essential to ensure the longevity and hygienic operation of your Spectra accessory kit. Always clean parts immediately after each use.

Image: Spectra breast pump parts, including the bottle, flange, and tubing, arranged on a surface, indicating they are ready for cleaning.
Instrukcje czyszczenia:
- Demontować: Separate all parts of the accessory kit.
- Umyć: Wash all parts that come into contact with breast milk (breast flange, milk bottle, backflow protector, duckbill valve) with warm soapy water. Use a dedicated brush for cleaning breast pump parts.
- Wypłukać: Rinse all parts thoroughly under clean running water.
- Suszenie na powietrzu: Place parts on a clean paper towel or drying rack and allow them to air dry completely. Do not use a cloth towel to dry, as this can transfer germs.
- Rury: Do not wash the tubing. If moisture or milk gets into the tubing, it should be replaced. The backflow protector prevents milk from entering the tubing and pump motor.
- Pomywaczka: Produkt nie nadaje się do mycia w zmywarce. Myć tylko ręcznie.
Harmonogram wymiany:
To maintain optimal performance and hygiene, certain parts of your accessory kit should be replaced periodically.

Image: A visual guide recommending replacement intervals: Spectra Duckbill Valves every 6 to 8 weeks, and Spectra Backflow Protectors every 3 to 4 months. It also advises purchasing two sets for double pumping.
- Duckbill Valves: Replace every 6 to 8 weeks, or sooner if you notice a decrease in suction or visible wear.
- Backflow Protectors: Replace every 3 to 4 months, or if you notice any damage or milk residue inside.
- Rury: Replace if milk or moisture enters the tubing, or if it becomes discolored or damaged.
5. Rozwiązywanie Problemów
If you experience issues with your Spectra accessory kit, consider the following common troubleshooting steps:
- Niskie ssanie:
- Sprawdź, czy wszystkie części zostały prawidłowo i bezpiecznie zmontowane.
- Inspect the duckbill valve for tears or stretching; replace if necessary.
- Ensure the silicone diaphragm in the backflow protector is not torn or misaligned.
- Verify that the tubing is not kinked, damaged, or has moisture inside.
- Milk Leaking:
- Ensure the milk bottle is securely screwed onto the breast flange.
- Check the duckbill valve for proper seating and any damage.
- Dyskomfort podczas odciągania pokarmu:
- Re-evaluate your flange size. An incorrect size can cause pain or inefficient milk expression.
- Adjust the suction level on your pump to a comfortable setting.
For further assistance, please contact Spectra customer support.
6. Specyfikacje
| Wymiary produktu | 7.17 x 5.04 x 3.54 cala |
| Numer modelu przedmiotu | MM012340-24mm |
| Typ materiału | Silikon |
| Waga przedmiotu | 2.88 uncji |
| Można myć w zmywarce | NIE |
7. Gwarancja i wsparcie
Spectra Baby USA is committed to providing high-quality breast pumps and accessories. For specific warranty information regarding your Spectra product, please refer to the documentation included with your breast pump or visit the official Spectra Baby USA webstrona.
For customer care, product inquiries, or virtual consultations, please visit the official Spectra store or contact their support team directly.
Official Spectra Store: Visit Spectra Store on Amazon
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.