1. Koniec produktuview
The Kohler 76331-CP Shower Arm with 2-Way Diverter is a wall-mount fixture designed to direct water flow between a showerhead and a handshower. Constructed from brass, this unit features a polished chrome finish, engineered to resist corrosion and tarnishing. It includes a flange for installation and is compatible with standard 1/2-inch NPT connections.

Image 1.1: The Kohler 76331-CP Shower Arm with 2-Way Diverter, showcasing its polished chrome finish and integrated diverter mechanism.
2. Informacje dotyczące bezpieczeństwa
- Przed rozpoczęciem jakichkolwiek prac instalacyjnych lub konserwacyjnych należy zawsze zakręcić dopływ wody.
- Nosić odpowiedni sprzęt ochrony osobistej, taki jak okulary i rękawice ochronne.
- Jeśli masz wątpliwości co do jakiegokolwiek etapu instalacji, skonsultuj się z wykwalifikowanym hydraulikiem.
- Upewnij się, że wszystkie połączenia są solidne, aby zapobiec wyciekom.
- Do not overtighten connections, as this can damage the product or plumbing.
3. Zawartość opakowania
Przed rozpoczęciem instalacji sprawdź, czy wszystkie komponenty są obecne.
- Shower Arm with 2-Way Diverter
- Kołnierz
Note: Showerheads, handshowers, and additional flanges (K-76334 Traditional flange, K-76335 Square flange) are sold separately.
4. Specyfikacje
| Funkcja | Szczegół |
|---|---|
| Producent | Kohler |
| Numer modelu | 76331-CP |
| Numer części | 76331-CP |
| Tworzywo | Konstrukcja mosiężna |
| Skończyć | Polerowany chrom |
| Metoda instalacji | Montaż na ścianie |
| Typ połączenia | 1/2 cala NPT |
| Cechy specjalne | Funkcja odgałęźnika |
| Waga przedmiotu | 1.1 funta |
| Wymiary produktu | 4.75 x 3.06 x 12.93 cala |
| Przepływ | 2.5 galona na minutę |
5. Instrukcje instalacji
5.1 Wymagane narzędzia i materiały (nie dołączone)
- Klucz nastawny
- Plumber's tape (thread sealant)
- Miękka tkanina
5.2 Kroki instalacji
- Wyłącz dopływ wody: Locate and turn off the main water supply to your shower area. Open existing shower faucets to relieve pressure.
- Remove Existing Shower Arm (if applicable): Unscrew the existing shower arm from the wall fitting. Clean any old sealant or debris from the wall pipe threads.
- Prepare New Shower Arm: Apply plumber's tape clockwise around the threaded end of the new Kohler shower arm (the end that connects to the wall). Ensure several wraps for a watertight seal.
- Install Flange: Slide the decorative flange over the shower arm, ensuring it faces the wall.
- Attach Shower Arm to Wall: Carefully thread the shower arm into the 1/2-inch NPT wall fitting. Hand-tighten first, then use an adjustable wrench to tighten an additional 1/2 to 1 full turn until secure and properly oriented. Do not overtighten.
- Position Flange: Slide the flange flush against the wall to cover the opening.
- Install Showerhead and Handshower: Attach your desired showerhead to the top outlet and your handshower hose to the bottom outlet of the diverter. Apply plumber's tape to these connections as well.
- Test szczelności: Slowly turn the main water supply back on. Check all connections for leaks. If leaks occur, turn off water, tighten connections slightly, and re-test.
6. Instrukcja obsługi
The 2-way diverter allows you to easily switch water flow between your main showerhead and a connected handshower.
- To use the Showerhead: Ensure the diverter handle is in the position that directs water upwards to the showerhead.
- To use the Handshower: Rotate the diverter handle to the position that directs water downwards to the handshower.
- To turn off water: Use your shower's main faucet handle to stop the water flow. The diverter only controls the direction of water, not the on/off function or temperature.
7. Konserwacja i pielęgnacja
- Czyszczenie: Wyczyść polerowaną chromowaną powierzchnię miękką,amp ściereczką. Unikaj środków czyszczących o działaniu ściernym, silnych środków chemicznych i gąbek szorujących, ponieważ mogą one uszkodzić wykończenie.
- Czyszczenie punktowe: For water spots, use a mild soap solution and rinse thoroughly with clean water, then dry with a soft cloth.
- Regularna kontrola: Periodically check connections for any signs of leaks or corrosion.
8. Rozwiązywanie Problemów
| Problem | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| Wycieki wody z połączeń | Loose connections; insufficient plumber's tape | Turn off water supply, tighten connections, reapply plumber's tape if necessary. |
| Diverter not switching flow completely | Debris in diverter mechanism; worn internal components | Flush the system by running water through both outlets. If problem persists, contact Kohler customer support. |
| Niskie ciśnienie wody | Main water supply issue; clogged showerhead/handshower | Check household water pressure. Clean or replace showerhead/handshower if clogged. |
9. Gwarancja i wsparcie
For specific warranty information and customer support, please refer to the official Kohler website or contact Kohler directly. Keep your purchase receipt for warranty claims.
Kohler Official Webstrona: www.kohler.com