1. Wprowadzenie
Thank you for choosing the ENKI Windsor SH0155 Thermostatic Shower System. This manual provides essential information for the safe installation, operation, and maintenance of your new shower system. Please read these instructions carefully before installation and retain them for future reference.
2. Informacje dotyczące bezpieczeństwa
- Installation should be performed by a qualified professional plumber in accordance with local plumbing codes and regulations.
- Przed rozpoczęciem jakichkolwiek prac instalacyjnych lub konserwacyjnych należy upewnić się, że główne dopływy wody są zamknięte.
- Always test water temperature before use to prevent scalding, especially for children and the elderly.
- Do not use abrasive cleaners or materials on the shower system, as this may damage the finish.
- The anti-scald device is integrated to prevent sudden temperature fluctuations. If the cold water supply fails, the shower will automatically shut off.
3. Zawartość opakowania
Przed rozpoczęciem instalacji należy sprawdzić, czy wszystkie elementy są obecne i nieuszkodzone:
- 1 x Thermostatic Dual Shower Valve
- 1 x Rigid Riser Rail
- 1 x 200mm Rain Shower Head
- Installation hardware (screws, wall plugs, seals)
4. Konfiguracja i instalacja
4.1 Wymagania przedinstalacyjne
- Ciśnienie wody: Minimum required water pressure is 0.5 bar. For optimal performance, a minimum of 1.0 bar is recommended.
- Plumbing System: Suitable for all plumbing systems. Note: The shower valve will not operate effectively on a gravity-fed tank system unless a booster pump is installed.
- Znajomości: 1/2 inch hot/cold inlets. The distance between connections should be 147-153 mm.
4.2 Kroki instalacji
- Przygotuj obszar: Ensure the wall surface is clean, flat, and capable of supporting the shower system's weight. Turn off the main water supply.
- Mount the Thermostatic Valve: Position the valve at the desired height. Mark and drill holes for mounting. Secure the valve to the wall, ensuring the hot water supply is connected to the left inlet and cold water to the right inlet (typically marked). The connection distance is 147-153mm.
- Install the Rigid Riser Rail: Assemble the riser rail components. The riser rail can be cut to the desired length to achieve the perfect shower head height. Secure the riser rail to the wall using the provided brackets and hardware.
- Zamontuj słuchawkę prysznica: Screw the 200mm rain shower head onto the riser arm. Ensure all connections are tight and sealed with PTFE tape where necessary.
- Test szczelności: Slowly turn on the main water supply and check all connections for leaks. Rectify any leaks before proceeding.

Figure 1: Technical drawing showing dimensions and connections for the ENKI Windsor SH0155 shower system. Note the 200mm shower head and 147-153mm valve connection spacing.

Rysunek 2: Byłyample of the ENKI Windsor SH0155 shower system installed in a contemporary bathroom setting, showcasing its antique bronze finish.
5. Instrukcja obsługi
The ENKI Windsor SH0155 features a dual-control thermostatic valve:
- Kontrola temperatury: One handle controls the water temperature. Rotate it to adjust the temperature to your preference. The thermostatic cartridge maintains a constant temperature, preventing sudden changes.
- Kontrola przepływu wody: The other handle controls the water flow. Rotate it to turn the shower on/off and adjust the intensity of the water flow.
6. Konserwacja
- Czyszczenie: To maintain the antique bronze finish, clean regularly with a soft, damp cloth. Do not use abrasive cleaners, scouring pads, or chemical cleaning agents, as these can damage the surface.
- Kamień kotłowy: In hard water areas, limescale may build up on the shower head nozzles. Gently rub the silicone nozzles to dislodge any deposits. For stubborn build-up, use a mild limescale remover specifically designed for bathroom fixtures, following the manufacturer's instructions, and rinse thoroughly.
- Opieka ogólna: Periodically check all connections for tightness and signs of wear.
7. Rozwiązywanie Problemów
| Problem | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| Niski przepływ wody | Low water pressure; Blocked shower head nozzles; Partially closed isolation valves. | Check household water pressure; Clean shower head nozzles; Ensure isolation valves are fully open. |
| Temperatura wody ulega wahaniom | Inconsistent hot/cold water supply; Thermostatic cartridge issue. | Ensure stable hot and cold water pressure; If problem persists, contact a qualified plumber to inspect/replace the thermostatic cartridge. |
| Wyciek z połączeń | Loose connections; Damaged seals/washers. | Turn off water supply, tighten connections; Replace any damaged seals or washers. |
| Brak przepływu wody | Main water supply off; Blockage in pipes. | Check if main water supply is on; Consult a plumber for pipe inspection. |
8. Specyfikacje
| Funkcja | Szczegół |
|---|---|
| Numer modelu | SH0155 |
| Wymiary (dł. x szer. x wys.) | Wymiary 72 x 30 x 24 cm |
| Waga | 4.9 kilograma |
| Tworzywo | High-Quality Brass Body, Ceramic Handles |
| Skończyć | Antyczny brąz |
| Liczba uchwytów | 3 (1 for temperature, 1 for flow, 1 for diverter if applicable) |
| Rozmiar głowicy prysznicowej | 200 mm |
| Minimalne ciśnienie wody | 0.5 bar (1.0 bar recommended) |
| Połączenia wlotowe | 1/2 cala |
| Odległość połączenia | 147-153 mm |
| Anti-Scald Device | Zintegrowany |
9. Gwarancja i pomoc techniczna
ENKI products are designed for durability and quality. This product comes with up to 10 years cover, reflecting our commitment to lasting performance. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or visit the official ENKI webstrona.

Figure 3: ENKI offers extensive coverage for its products, ensuring peace of mind.
If you require technical assistance, have questions about installation, or need to report a fault, please contact ENKI customer support through our official website or your retailer. Please have your model number (SH0155) and proof of purchase ready.