1. Koniec produktuview
The AcuRite 06054M Solar Radiation Shield is designed to protect compatible temperature and humidity sensors from direct sunlight and other environmental elements. This protection ensures more accurate temperature and humidity readings by preventing solar radiation from artificially elevating sensor temperatures. Its louvered design allows for natural airflow while providing shade, making it suitable for both indoor and outdoor use.

2. Główne cechy
- Provides shade from sunlight and allows air to circulate through the shield to increase the accuracy of temperature readings during the day.
- Durable, all-weather construction, ideal for both indoor and outdoor use.
- Compatible AcuRite sensors attach easily inside the shield for simple installation.
- Integrated hanger on the top cover and keyhole mount on the back of the cover offer multiple mounting options.
- Dimensions: 19 cm (7.5 inches) high x 13.7 cm (5.4 inches) wide x 10 cm (3.9 inches) deep.
3. Zawartość opakowania
- AcuRite 06054M Solar Radiation Shield (1 unit)
Note: Compatible temperature and humidity sensors are sold separately and are not included with this shield.
4. Konfiguracja i instalacja
Proper placement and installation of the solar radiation shield are crucial for obtaining accurate sensor readings. Follow these steps for optimal performance:
- Rozmieszczenie czujnika: Open the shield by gently separating the louvered sections. Insert your compatible AcuRite temperature and humidity sensor into the designated clips or slot inside the shield. Ensure the sensor is securely held and positioned centrally within the shield's cavity.
- Reassemble Shield: Carefully reassemble the louvered sections, ensuring they click firmly into place.
- Miejsce montażu: Choose an outdoor location that is representative of the general area you wish to monitor. Avoid placing the shield directly against a building wall, fence, or other large structures that can absorb and radiate heat, which may affect readings.
- Metoda montażu: The shield offers two primary mounting options:
- Zintegrowany wieszak: Use the loop on the top of the shield to hang it from a hook, branch, or shepherd's hook.
- Montaż w otworze na klucz: Utilize the keyhole slot on the back of the shield to mount it flush against a flat surface using a screw (not included).
- Wysokość: For best results, mount the shield at a height that allows for good airflow around it, typically 1.2 to 1.8 meters (4 to 6 feet) above the ground.



5. Działanie
The AcuRite Solar Radiation Shield operates passively. Once a compatible sensor is installed inside and the shield is mounted in an appropriate location, it continuously protects the sensor from direct solar radiation and allows for accurate ambient temperature and humidity measurements. No power source or active controls are required for the shield itself.
6. Konserwacja
To ensure the longevity and continued performance of your solar radiation shield, periodic maintenance is recommended:
- Czyszczenie: Occasionally inspect the shield for dirt, dust, or debris accumulation on the louvers. Clean with a soft, damp cloth. Avoid abrasive cleaners that could damage the plastic.
- Kontrola: Periodically check the shield for any signs of damage, such as cracks or loose sections, especially after severe weather conditions. Ensure the sensor inside remains securely in place.
- Przepływ powietrza: Confirm that the area around the shield remains clear of obstructions that could impede airflow, such as growing vegetation.
7. Rozwiązywanie Problemów
If you experience issues with temperature or humidity readings while using the solar radiation shield, consider the following:
- Niedokładne odczyty temperatury:
- Bezpośrednie narażenie na działanie promieni słonecznych: Even with the shield, if the sensor is exposed to direct sunlight due to improper orientation or extreme sun angles, readings may be elevated. Adjust placement if necessary.
- Źródła ciepła: Ensure the shield is not mounted too close to heat-radiating surfaces like asphalt, concrete, or building walls.
- Słaby przepływ powietrza: Verify that air can freely circulate through the shield's louvers. Clear any blockages.
- Niedokładne odczyty wilgotności:
- Ground Proximity: If the shield is mounted too close to the ground, humidity readings may appear higher due to ground moisture.
- Akumulacja wody: Ensure no water is pooling inside the shield after rain, which could affect humidity readings.
- Sensor Not Fitting: Confirm that your sensor is compatible with the AcuRite 06054M shield. While some other brands may fit, optimal fit is guaranteed with AcuRite sensors.
8. Specyfikacje
| Numer modelu | 06054 mln |
| Marka | AcuRite |
| Tworzywo | Plastikowy |
| Kolor | Biały |
| Wymiary produktu (wys. x szer. x gł.) | 19.05 cm x 13.65 cm x 10.16 cm (7.5 x 5.4 x 4 cala) |
| Waga | 312.98 gramów |
| Zalecane zastosowanie | Outdoor temperature and humidity sensor protection |
| Funkcja specjalna | Lightweight, All-weather durable construction |
9. Gwarancja i wsparcie
Specific warranty information for the AcuRite 06054M Solar Radiation Shield is not provided in this manual. For detailed warranty terms, product support, or to purchase compatible sensors and accessories, please visit the official AcuRite webodwiedź witrynę lub skontaktuj się bezpośrednio z działem obsługi klienta.