Astralpool 57178

Instrukcja obsługi pompy perystaltycznej ASTRALPOOL 12 l/h 1 bar (model 57178)

1. Wprowadzenie

1.1 Produkt powyżejview

The ASTRALPOOL Peristaltic Pump, Model 57178, is designed for precise fluid dosing applications. This pump features continuous flow regulation, adjustable from 0% to 100% of its maximum capacity. Flow adjustment is managed by varying the motor speed via a potentiometer conveniently located on the pump's front panel. It is capable of delivering up to 12 liters per hour at a maximum pressure of 1 bar.

1.2 Informacje dotyczące bezpieczeństwa

Please read and understand all safety instructions before installing, operating, or performing maintenance on this pump. Failure to follow these instructions may result in personal injury or equipment damage.

  • Przed przystąpieniem do prac instalacyjnych lub konserwacyjnych należy zawsze odłączyć zasilanie.
  • Ensure the pump is installed in a dry, well-ventilated area, protected from direct sunlight and extreme temperatures.
  • Sprawdź, czy napięcie zasilania jest prawidłowetage matches the pump's requirements (230 Volts AC).
  • Do not operate the pump with damaged cables or connections.
  • Wear appropriate personal protective equipment (PPE) when handling chemicals or performing maintenance.

2. Konfiguracja i instalacja

2.1 Montaż pompy

Select a stable, vertical surface for mounting the pump. Ensure there is adequate space around the pump for ventilation and access for maintenance. Use appropriate fasteners to secure the pump firmly to the chosen surface.

2.2 Podłączenie elektryczne

The pump requires a 230 Volts AC power supply. Connect the pump to a grounded electrical outlet. It is recommended to use a dedicated circuit with appropriate overcurrent protection. Consult a qualified electrician if you are unsure about electrical connections.

2.3 Połączenia płynów

Identify the inlet and outlet ports on the pump. The inlet port typically draws fluid from the source, and the outlet port delivers the fluid. Connect appropriate tubing to these ports, ensuring all connections are secure and leak-free. Use tubing compatible with the fluid being pumped and capable of withstanding the operating pressure.

Astralpool Peristaltic Pump 57178 showing the transparent cover, internal tubing, and connection ports.

This image displays the Astralpool Peristaltic Pump, model 57178. The pump features a blue casing with a transparent front cover, allowing visibility of the internal peristaltic mechanism and tubing. At the bottom, two black connection ports are visible for fluid inlet and outlet.

3. Instrukcja obsługi

3.1 Pierwsze uruchomienie

  1. Ensure all fluid connections are secure and the pump is properly mounted.
  2. Verify that the fluid source is available and the discharge line is correctly routed.
  3. Plug the pump into the power supply.

3.2 Regulacja przepływu

The pump's flow rate is adjusted using the potentiometer located on the front panel. Rotate the potentiometer clockwise to increase the flow rate and counter-clockwise to decrease it. The flow can be continuously regulated from 0% to 100% of the pump's maximum capacity (12 L/H).

4. Konserwacja

4.1 Ogólna konserwacja

  • Regularly inspect the tubing for signs of wear, cracks, or blockages. Replace tubing as necessary.
  • Check all connections for leaks and tighten if required.
  • Keep the pump's exterior clean and free from dust and debris.

4.2 Czyszczenie

To clean the pump, first disconnect it from the power supply. Wipe the exterior with a damp cloth. If the internal tubing requires cleaning, follow the manufacturer's guidelines for flushing the system with an appropriate cleaning solution, ensuring it is compatible with the pump materials and the fluids being handled.

5. Rozwiązywanie Problemów

ProblemMożliwa przyczynaRozwiązanie
Pompa nie uruchamia sięBrak zasilania
Uszkodzony kabel zasilający
Sprawdź podłączenie zasilania i gniazdko
Inspect and replace cable if damaged
Brak przepływu płynuRurka zagięta lub zablokowana
Zatkany filtr wlotowy
Potentiometer set to 0%
Sprawdź i wyczyść rury
Oczyścić lub wymienić filtr wlotowy
Adjust potentiometer to desired flow rate
Niespójny przepływPowietrze w linii
Worn tubing
Odpowietrzyć układ
Replace peristaltic tubing
Wyciek na połączeniachLuźne połączenia
Damaged seals/tubing
Dokręć wszystkie połączenia
Inspect and replace seals or tubing

6. Specyfikacje techniczne

SpecyfikacjaWartość
MarkaAstralpool
Numer modelu57178
Wymiary produktu (dł. x szer. x wys.)Wymiary 23 x 11 x 13 cm
Waga900 gramów
Tomtage230 V (AC)
PrzepływUp to 12 L/H (continuously adjustable)
Maksymalne ciśnienie1 bar
Dostępność części zamiennychInformacje niedostępne