Wstęp
This manual provides detailed instructions for the installation, operation, and maintenance of the Legrand Watt Stopper LMDW-102-W DLM Dual-Tech Digital 2-Button Occupancy Sensor. This device is designed to automatically control lighting based on occupancy detection, utilizing both Passive Infrared (PIR) and Ultrasonic technologies for enhanced accuracy. It features a 2-button interface and is programmable via an infrared remote.
Identyfikator produktu: 0210023292
Cechy produktu
- DLM System 2-Button Switch
- 24VDC RJ45 Connection
- Dual-Tech (PIR & Ultrasonic) Occupancy Detection
- Infrared Remote Programmable
- Białe wykończenie
Informacje dotyczące bezpieczeństwa
Please read and understand all instructions before installing or operating this device. Failure to follow these instructions may result in electrical shock, fire, or property damage. Installation should be performed by a qualified electrician in accordance with all national and local electrical codes.
- OSTRZEŻENIE: Przed przystąpieniem do instalacji lub serwisowania należy wyłączyć zasilanie za pomocą wyłącznika automatycznego lub skrzynki bezpiecznikowej.
- To urządzenie jest przeznaczone do TYLKO do użytku wewnątrz pomieszczeń.
- Nie należy instalować w miejscach wilgotnych lub narażonych na działanie ekstremalnych temperatur.
- Sprawdź, czy wszystkie połączenia są solidne i właściwie zaizolowane.
Konfiguracja i instalacja
The LMDW-102-W sensor is designed for wall-mount installation and connects via a 24VDC RJ45 connection as part of a Digital Lighting Management (DLM) system.
- Odłączenie zasilania: Before beginning installation, ensure that power to the circuit is turned off at the main service panel.
- Montowanie: Mount the sensor in a standard wall box. Ensure the mounting plate is securely fastened to the wall box.
- Okablowanie: Connect the RJ45 cable from the DLM system to the RJ45 port on the back of the sensor. Ensure the connection is firm. This device operates on 24VDC.
- Orientacja czujnika: Position the sensor to ensure optimal coverage of the desired area. Avoid obstructions that might block the sensor's view.
- Bezpieczne urządzenie: Once wired, carefully push the device into the wall box and secure it with the provided screws. Attach the wall plate (not included) if applicable.
- Przywrócenie zasilania: Restore power at the circuit breaker. The sensor will perform a self-test.

Instrukcja obsługi
The LMDW-102-W sensor provides both automatic occupancy detection and manual control via its two push buttons.
Automatic Operation (Occupancy Detection)
The sensor uses both Passive Infrared (PIR) and Ultrasonic technologies to detect occupancy. When motion is detected, connected lights will turn on automatically. After a period of no detected occupancy (determined by system settings), the lights will turn off automatically.
Sterowanie ręczne
The two buttons on the sensor allow for manual override of the automatic control:
- Górny przycisk: Typically used to manually turn lights ON or to increase light levels.
- Dolny przycisk: Typically used to manually turn lights OFF or to decrease light levels.
The exact function of these buttons can be programmed using an infrared remote control (sold separately) to suit specific application requirements within the DLM system.
Infrared Remote Programming
The sensor's settings, such as sensitivity, time delay, and button functions, can be adjusted using a compatible Legrand Watt Stopper infrared remote control. Refer to the remote control's manual for specific programming instructions.
Konserwacja
The LMDW-102-W sensor requires minimal maintenance to ensure optimal performance.
- Czyszczenie: Periodically wipe the sensor lens and housing with a soft, dry cloth. Do not use abrasive cleaners or solvents, as these can damage the device.
- Kontrola: Regularnie sprawdzaj czujnik pod kątem uszkodzeń fizycznych i luźnych połączeń.
- Przeszkody: Ensure that the sensor's detection area remains clear of obstructions (e.g., furniture, tall plants) that could block its view i wpływają na wydajność.
Rozwiązywanie problemów
| Problem | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| Lights do not turn on automatically. | No motion detected; power off; incorrect wiring; sensor obstructed; sensitivity too low. | Verify motion in detection area; check circuit breaker; inspect wiring; clear obstructions; adjust sensor sensitivity via remote. |
| Lights remain on. | Constant motion detected; time delay set too long; sensor faulty. | Ensure no constant motion; adjust time delay via remote; contact support if issue persists. |
| Światła gasną zbyt szybko. | Time delay set too short; sensor sensitivity too low; sensor obstructed. | Adjust time delay via remote; increase sensor sensitivity; clear obstructions. |
| Manual buttons do not respond. | No power; incorrect programming; button malfunction. | Check power; verify programming with remote; contact support. |
Specyfikacje
| Funkcja | Szczegół |
|---|---|
| Model | LMDW-102-W |
| Marka | Legrand (Wattstopper) |
| Tryb działania | Manual / Automatic (Occupancy) |
| Objętość operacyjnatage | 24 V prądu stałego |
| Technologia wykrywania | Dual-Tech (PIR & Ultrasonic) |
| Typ złącza | RJ45 (for DLM System) |
| Typ przełącznika | Push Button (2-way circuit) |
| Metoda kontroli | Pilot (podczerwień) |
| Typ montażu | Montaż ścienny |
| Kolor | Biały |
| Tworzywo | Stainless Steel (Contact Material) |
| Pozycja Wymiary (dł. x szer. x wys.) | 5 x 2 x 2 cala |
| Waga przedmiotu | 0.3 funtów |
| Międzynarodowa Ocena Ochrony | IP54 |
| Specyfikacja Met | RoHS |
Gwarancja i wsparcie
For warranty information and technical support, please refer to the official Legrand Watt Stopper webOdwiedź witrynę lub skontaktuj się z działem obsługi klienta. Zachowaj paragon zakupu na wypadek reklamacji.
Zasoby internetowe: Legrand Watt Stopper Official Webstrona