Venitem MURANO-LS

Venitem MURANO-LS Self-Powered Anti-Foam Siren Instruction Manual

Model: MURANO-LS | Brand: Venitem

1. Wprowadzenie

The Venitem MURANO-LS is a self-powered anti-foam siren designed for robust security applications. It features advanced technical capabilities including automatic speaker and battery efficiency testing, LED flasher with alarm memory, and flexible installation signaling. Built with SMD technology and protected against polarity reversal, this siren ensures reliable performance in various environments. Its IP44 rating guarantees protection against dust and splashing water.

Venitem MURANO-LS Self-Powered Anti-Foam Siren

Rysunek 1: Venitem MURANO-LS Self-Powered Anti-Foam Siren. This image displays the external view of the siren, typically mounted on a wall, showcasing its design and robust casing.

2. Informacje dotyczące bezpieczeństwa

  • Przeczytaj wszystkie instrukcje: Before installation and operation, carefully read and understand all instructions in this manual.
  • Wykwalifikowany personel: Installation and maintenance should only be performed by qualified personnel to ensure safety and proper functioning.
  • Zasilanie: Ensure the power supply matches the product specifications (12 V DC). Disconnect power before any installation or maintenance.
  • Biegunowość: The electronic circuit is protected against polarity reversal, but always ensure correct wiring to prevent damage.
  • Montowanie: Mount the siren securely on a stable surface to prevent accidental detachment.
  • Ciśnienie akustyczne: The siren produces a high sound pressure level (105 dB at 3m). Avoid prolonged exposure to prevent hearing damage.
  • Warunki środowiskowe: The siren is rated IP44, providing protection against splashing water and solid objects larger than 1mm. Do not immerse the device in water.

3. Konfiguracja i instalacja

3.1. Koniec komponentówview

  • ABS plastic siren base
  • Centering bulb
  • Inner and outer covers (varnished ABS, pearlescent or metallic colors)
  • LED flasher (smoked dome)
  • Double magnetic reed tamper switch (anti-opening and anti-tear)
  • Electronic circuit board (SMD technology, resin-immersed)
  • Battery housing (for 12 V 2.2 Ah battery, battery not included)

3.2. Montaż syreny

  1. Select a suitable mounting location, ensuring it is secure and provides optimal sound coverage.
  2. Open the siren casing by disengaging the tamper przełączniki.
  3. Use the ABS plastic siren base as a template to mark drilling points on the wall.
  4. Drill holes and secure the siren base to the wall using appropriate fasteners.
  5. Ensure the centering bulb is correctly positioned.

3.3. Okablowanie i podłączenie zasilania

  1. Connect the 12 V DC power supply to the designated terminals. The electronic circuit is protected against polarity reversal.
  2. Install a 12 V 2.2 Ah battery (not included) into the battery housing. Ensure correct polarity.
  3. Connect the control wires for activation. The siren supports 2 or 3-wire activation and programming for positive or negative control.
  4. Connect the ON-OFF installation signaling wires (for permanent or timed signaling).
  5. Verify all connections are secure and correct before proceeding.

3.4. Programowanie

The MURANO-LS siren offers flexible programming options:

  • Wejście sterujące: Program for positive or negative control signals.
  • Tryb aktywacji: Choose between 2-wire or 3-wire activation.
  • Sound and Timing: Select from 4 distinct sound programs and timing configurations.
  • Cykle alarmowe: Configure for 4 daily alarm cycles or infinite cycles.
  • Refer to the detailed wiring diagram (not provided in this manual, typically found in a separate installation guide) for specific programming jumper or switch settings.

4. Instrukcja obsługi

4.1. Pierwsze uruchomienie

  1. After completing installation and wiring, apply 12 V DC power to the siren.
  2. The siren will perform an automatic test of the speaker and battery efficiency.
  3. Observe the LED flasher for initial status indications.

4.2. Aktywacja alarmu

When an alarm signal is received from the control panel (via the programmed 2 or 3-wire input):

  • The siren will activate, emitting the pre-programmed sound.
  • The LED flasher will activate, providing visual indication of the alarm.
  • The flasher includes an alarm memory function, indicating if an alarm occurred even after it has ceased.

4.3. Siren Failure Output

The siren provides an output signal in case of a siren failure, allowing it to be connected to a control panel for remote monitoring of its operational status.

5. Konserwacja

  • Regularne czyszczenie: Okresowo czyść zewnętrzną część syreny miękką,amp ściereczka. Nie należy używać środków czyszczących o właściwościach ściernych ani rozpuszczalników.
  • Sprawdzenie baterii: The siren performs an automatic battery efficiency test. If a battery fault is indicated (e.g., via the siren failure output or specific LED patterns, refer to your control panel manual), replace the 12 V 2.2 Ah battery with a new one of the same specifications.
  • Tamper Switches: Ensure the double magnetic reed tamper switches are clean and free from obstructions to guarantee proper anti-opening and anti-tear protection.
  • Kontrola wizualna: Regularly inspect the siren for any signs of physical damage, loose connections, or environmental wear.
  • Inspekcja profesjonalna: It is recommended to have the siren professionally inspected and serviced by a qualified technician at least once a year.

6. Rozwiązywanie Problemów

This section provides solutions to common issues. For problems not listed here, or if the issue persists, please contact Venitem technical support or your installer.

ProblemMożliwa przyczynaRozwiązanie
Siren does not activateNo power supply; Incorrect wiring; Control signal not received; Dead battery.Check 12 V DC power connection; Verify all wiring connections; Ensure control panel is sending an alarm signal; Check and replace battery if necessary.
LED flasher not workingFlasher fault; Power issue.Check power supply; Contact technical support if flasher remains inactive during an alarm.
Siren failure output active (false alarm)Tamper switch triggered; Internal fault; Low battery.Ensure siren casing is properly closed and secured; Check battery status; Contact technical support.
Siren sounds continuously or erraticallyFaulty control signal; Internal circuit issue.Verify control panel output; Disconnect power and reconnect; If issue persists, contact technical support.

7. Specyfikacje techniczne

FunkcjaSpecyfikacja
ModelMURANO-LS
MarkaVenitem
Zasilacz12 V prądu stałego
Prąd spoczynkowy15mA
Alarm Current (with battery)500mA
Poziom ciśnienia akustycznego105 dB(A) w odległości 3 m
Obudowa akumulatoraFor 12 V 2.2 Ah battery (battery not included)
Wymiary (szer. x wys. x gł.)Wymiary: 236 x 312 x 109 mm
Stopień ochronyIP44
CertyfikatyIMQ Level II
CechyAutomatic speaker/battery test, Siren failure output, LED flasher with alarm memory, ON-OFF installation signaling, 4 sound/timing programs, 2/3-wire activation, Double magnetic reed tampeee.
BudowaABS plastic base, resin-immersed SMD electronic circuit, varnished ABS covers.

8. Gwarancja i wsparcie

8.1. Informacje o gwarancji

Specific warranty details for the Venitem MURANO-LS siren are typically provided at the point of purchase or within separate documentation included with the product. Please retain your proof of purchase for warranty claims. The warranty generally covers manufacturing defects under normal use. Damage resulting from improper installation, misuse, or unauthorized modifications is not covered.

8.2. Wsparcie techniczne

For technical assistance, troubleshooting, or inquiries regarding your Venitem MURANO-LS siren, please contact your authorized Venitem dealer or the installer of your security system.

You may also visit the official Venitem website for further information or to find contact details for customer support in your region.

© 2026 Venitem. All rights reserved. Information subject to change without notice.

Powiązane dokumenty - MURANO-LS

Przedview Instrukcja techniczna Venitem HEMA L/LS/LSP: Sygnalizator dźwiękowy LED o wysokiej jasności
Niniejsza instrukcja techniczna zawiera szczegółowe informacje na temat sygnalizatorów akustycznych Venitem HEMA L, HEMA LS i HEMA LSP. Zawiera ona ogólny opis, parametry techniczne, schematy okablowania, instrukcje instalacji oraz wskazówki dotyczące rozwiązywania problemów dla tych jasnych sygnalizatorów LED z funkcją anty-T.amper i właściwości zapobiegające pienieniu i wierceniu.
Przedview Instrukcja techniczna i specyfikacja sygnalizatora akustycznego VENITEM serii HEMA
Kompleksowa instrukcja techniczna i specyfikacje sygnalizatorów akustycznych serii VENITEM HEMA L, HEMA LS i HEMA LSP, szczegółowo opisujące funkcje, instalację, okablowanie i ustawienia zaawansowanych systemów bezpieczeństwa.
Przedview Venitem MURANO F24EN Instrukcja techniczna
Kompleksowa instrukcja techniczna sygnalizatora akustycznego Venitem MURANO F24EN, obejmująca specyfikacje, instalację, okablowanie i konfigurację.
Przedview KR-SJ1 Bezprzewodowa syrena zewnętrzna zasilana energią słoneczną – dane techniczne i działanie
Szczegółowe dane techniczne, funkcje i instrukcja obsługi bezprzewodowej syreny zewnętrznej KR-SJ1 zasilanej energią słoneczną. Dowiedz się więcej o jej instalacji, parowaniu z systemami alarmowymi i samodzielnym działaniu.
Przedview PS-89 12V Wired Mini Horn Siren Installation and Troubleshooting Guide
Learn how to install and operate the PS-89 12V wired mini horn siren. This guide covers wiring instructions, precautions, and operational details for this 105dB-110dB home security alarm.
Przedview Dynoracing BX101632 Alarm Siren Wiring Diagram
Learn how to wire your Dynoracing BX101632 12V alarm siren to a power source or alarm panel with this straightforward wiring diagram. Essential for car alarm system installations.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.