Wstęp

This manual provides essential instructions for the installation, operation, and maintenance of your CISA DGT Vision Electronic Safe, model 82750. Please read this manual thoroughly before using the safe to ensure proper function and security.

Informacje dotyczące bezpieczeństwa

  • Install the safe in a location that is difficult to access with burglary tools.
  • Do not store the emergency power cable or any backup keys (if applicable) inside the safe.
  • Regularly check battery status and replace batteries when indicated.
  • Change the opening code periodically for enhanced security.
  • Ensure the safe is securely anchored to a wall or floor as per installation instructions.

Zawartość opakowania

  • CISA DGT Vision Electronic Safe (Model 82750)
  • Emergency Power Cable (for external power)
  • Mounting Hardware (screws, anchors - may vary by region/package)
  • Instrukcja obsługi (ten dokument)
CISA DGT Vision Electronic Safe packaging box

Image: The CISA DGT Vision Electronic Safe as it appears in its packaging box, secured with white straps.

Konfiguracja i instalacja

The CISA DGT Vision safe is designed for secure installation within furniture or anchored to a wall/floor. Proper installation is crucial for security.

Wybór miejsca instalacji

  • Select a discreet and secure location, preferably out of plain sight.
  • Ensure the mounting surface (wall or floor) is structurally sound and can support the weight of the safe and its contents.
  • Avoid locations with excessive humidity or extreme temperatures.

Zakotwiczenie sejfu

The safe features pre-drilled holes for anchoring.

  1. Ustaw sejf w wybranym miejscu.
  2. Zaznacz punkty wiercenia przez wcześniej nawiercone otwory z tyłu lub spodu sejfu na powierzchni montażowej.
  3. Move the safe and drill appropriate holes in the marked positions.
  4. Insert suitable anchors (not always included, check package contents) into the drilled holes.
  5. Reposition the safe and secure it using the provided or appropriate screws. Tighten all screws firmly.
Wnętrze view of the CISA DGT Vision Electronic Safe showing pre-drilled mounting holes

Obraz: Wnętrze view of the CISA DGT Vision Electronic Safe, showing the pre-drilled holes on the back and bottom for secure mounting.

Diagram showing dimensions of the CISA DGT Vision Electronic Safe

Image: Technical diagram illustrating the external dimensions of the CISA DGT Vision Electronic Safe: 420mm (width) x 300mm (height) x 350mm (depth).

Instrukcja obsługi

Initial Battery Installation

The electronic keypad requires 1.5V alkaline button cell batteries.

  1. Znajdź komorę baterii, zazwyczaj znajduje się ona po wewnętrznej stronie drzwi sejfu.
  2. Włóż baterie, zwracając uwagę na prawidłową polaryzację.
  3. Zamknij pokrywę komory baterii.
Close-up of the CISA DGT Vision electronic keypad

Obraz: szczegółowy view of the CISA DGT Vision electronic keypad, featuring numerical buttons and function keys.

Otwieranie sejfu po raz pierwszy

Upon initial setup, the safe typically has a factory-set default code (e.g., "1234" or "0000"). Refer to the specific instructions provided with your safe for the exact default code.

  1. Enter the default code on the keypad.
  2. Press the confirmation button (often marked with a key or checkmark symbol).
  3. The lock will disengage, and you can open the door.
Hand interacting with the CISA DGT Vision electronic keypad

Image: A hand pressing buttons on the CISA DGT Vision electronic keypad, demonstrating user interaction.

Setting/Changing Your Personal Code

It is highly recommended to change the default code immediately after the first opening.

  1. With the safe door open, locate the internal reset button (often a small button on the inside of the door or near the battery compartment).
  2. Press the reset button. The keypad will usually emit a beep or light up to indicate it's ready for a new code.
  3. Enter your new personal code (typically 4-8 digits).
  4. Naciśnij przycisk potwierdzenia.
  5. Re-enter your new personal code and press the confirmation button again to confirm.
  6. Przetestuj nowy kod przy otwartych drzwiach, zanim je zamkniesz.

Zamykanie i blokowanie sejfu

To lock the safe, simply close the door. The locking bolts will automatically engage.

Close-up of the CISA DGT Vision safe's locking bolts

Obraz: Zbliżenie view of the robust nickel-plated steel locking bolts of the CISA DGT Vision safe, extended from the door edge.

Konserwacja

Wymiana baterii

The keypad features indicator lights to warn of low battery power. Replace batteries promptly when this warning appears to avoid being locked out.

  1. Open the safe using your code.
  2. Znajdź komorę baterii po wewnętrznej stronie drzwi.
  3. Wyjmij stare baterie i zutylizuj je w odpowiedzialny sposób.
  4. Insert new 1.5V alkaline button cell batteries, observing correct polarity.
  5. Zamknij komorę baterii.

External Emergency Power

If batteries completely drain and you cannot open the safe, use the external emergency power cable.

  1. Locate the external power input port on the keypad (often a small socket).
  2. Connect the emergency power cable to this port and to a fresh 9V battery (not included).
  3. While holding the emergency power, enter your code to open the safe.
  4. Replace the internal batteries immediately after opening.

Opieka ogólna

  • Wyczyść zewnętrzną część sejfu miękką,amp płótno. Unikaj ściernych środków czyszczących.
  • Do not lubricate the electronic components or keypad.
  • Periodically check the anchoring bolts for tightness.

Rozwiązywanie problemów

Safe Does Not Open with Code

  • Nieprawidłowy kod: Ensure you are entering the correct code. Try again carefully.
  • Niski poziom naładowania baterii: Check the battery indicator. If low, replace batteries or use the external emergency power cable.
  • Awaria klawiatury: If the keypad does not respond at all, ensure batteries are correctly installed and charged. If issues persist, contact customer support.

Klawiatura nie odpowiada

  • Rozładowane baterie: Wymień baterie.
  • Incorrect Battery Installation: Verify polarity.

Safe Door Does Not Close Properly

  • Przeszkoda: Check for any items blocking the door or locking bolts.
  • Niewspółosiowość: Ensure the safe is installed on a level surface and the door hinges are not damaged.

Specyfikacje

FunkcjaSzczegół
Model82750
MarkaCISA
Wymiary (dł. x wys. x szer.)Wymiary: 420mm x 300mm x 350mm
Waga17.55 kg (38.7 funta)
TworzywoStal stopowa
Typ zamkaKlawiatura elektroniczna
Źródło zasilania1.5V Alkaline Button Cell Batteries (internal), 9V Battery (external emergency)
KolorAntracyt

Gwarancja i wsparcie

For warranty information and technical support, please refer to the documentation provided at the time of purchase or contact CISA customer service directly. Keep your purchase receipt as proof of purchase.

For further assistance, visit the official CISA webna miejscu lub skontaktuj się z autoryzowanym serwisem.

© 2023 CISA. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.