The PeakTech 5086 is a precise 3 3/4 digit (max. 3999) LCD digital LED Lux Meter designed for measuring the light intensity of various light sources, including LED, fluorescent, and traditional incandescent lamps with different light colors. It measures in Lux (lx), Footcandle (FC), or Candela (cd).
Unlike simpler lux meters that are typically calibrated for incandescent bulbs at 2856 K and provide inaccurate results for different color temperatures, the PeakTech 5086 allows for the adjustment of various light source factors. This enables accurate measurements for neon lamps, żarowe lamps, red, blue, yellow LEDs, or daylight. The device features 10 freely adjustable correction factors for different light sources, 99 memory locations for measurement values, and useful measurement functions such as minimum, maximum, and average value tracking, as well as data hold. This makes it suitable for professional applications in occupational safety or lighting system evaluation.
Główne cechy:
- Measures light intensity in Lux (lx), Footcandle (FC), or Candela (cd).
- 10 freely adjustable light source factors for various lamp Typy.
- Suitable for colored light sources, LEDs, and other bulb types.
- Measurement refresh rate: approximately 2.5 times per second.
- External sensor with cosine angle correction.
- Data Hold, Minimum/Maximum/Average (AVG) measurement functions.
- Automatic range selection and zero adjustment.
- 99 memory locations for storing measurement values.
2. Informacje dotyczące bezpieczeństwa
Przed użyciem urządzenia należy przeczytać i zrozumieć wszystkie instrukcje bezpieczeństwa. Nieprzestrzeganie tych instrukcji może spowodować obrażenia ciała lub uszkodzenie urządzenia.
- Nie wystawiaj urządzenia na działanie ekstremalnych temperatur, wilgoci ani bezpośredniego światła słonecznego.
- Unikaj silnych wibracji i uderzeń.
- Nie próbuj otwierać ani modyfikować urządzenia. Wszelkie prace serwisowe zlecaj wykwalifikowanemu personelowi.
- Upewnij się, że baterie są włożone z zachowaniem prawidłowej polaryzacji. Wyjmij baterie, jeśli urządzenie nie będzie używane przez dłuższy czas.
- Keep the sensor clean and free from obstructions to ensure accurate readings.
3. Zawartość opakowania
Sprawdź, czy w przesyłce znajdują się wszystkie wymienione poniżej elementy:
- PeakTech 5086 Digital LED Lux Meter with external sensor
- Torba transportowa
- Baterie (zainstalowane fabrycznie lub dołączone osobno)
- Instrukcja obsługi
4. Układ urządzenia
The PeakTech 5086 consists of a main unit with an LCD display and control buttons, and an external light sensor connected via a coiled cable. The sensor is equipped with a protective cap.

Rysunek 4.1: PeakTech 5086 Digital LED Lux Meter showing the main display unit and the external light sensor with its protective cap removed.
Sterowanie i wyświetlacz:
- Wyświetlacz LCD: Shows measurement values, units (Lux, FC, Cd), battery status, and active functions (e.g., HOLD, MIN, MAX, AVG, Light Source factor).
- Przycisk zasilania (⏻): Włącza lub wyłącza urządzenie.
- LX/FC/CD Button: Toggles between Lux, Footcandle, and Candela measurement units.
- Przycisk MEM/READ: Accesses memory functions to store or recall readings.
- HOLD/L.S. Button: Activates Data Hold function or enters Light Source factor adjustment mode.
- Przycisk ZERO: Performs zero adjustment for the sensor.
- W górę (▲) / W dół (▼) Przyciski: Used for navigation and adjusting values in settings modes.
5. Konfiguracja
5.1 Instalacja baterii
The PeakTech 5086 typically comes with batteries pre-installed. If not, or if batteries need replacement:
- Znajdź pokrywę komory baterii znajdującą się z tyłu jednostki głównej.
- Open the cover by sliding or unscrewing it (refer to the diagram in the full manual if unsure).
- Insert the required batteries (usually AAA or 9V, check the compartment for markings) ensuring correct polarity (+/-).
- Dokładnie zamknij pokrywę komory baterii.
5.2 Podłączanie czujnika
The external sensor is permanently attached via a coiled cable. Ensure the cable is not damaged or excessively stretched. The sensor head should be clean and the protective cap removed before taking measurements.
6. Instrukcja obsługi
6.1 Włączanie/wyłączanie
- Wciśnij przycisk zasilania (⏻) to turn the device on. The display will illuminate and show a reading.
- Naciśnij i przytrzymaj przycisk zasilania (⏻) na kilka sekund, aby wyłączyć urządzenie.
6.2 Unit Selection (Lux/FC/Cd)
- Naciśnij LX/FC/CD button to cycle through the available measurement units: Lux (lx), Footcandle (FC), and Candela (cd). The selected unit will be displayed on the LCD.
6.3 Regulacja zera
- Before taking measurements, especially in low light conditions, it is recommended to perform a zero adjustment.
- Place the protective cap over the sensor to block all light.
- Naciśnij ZERO button. The display should show "0" or a very small value.
- Remove the protective cap before measuring.
6.4 Setting Light Source Factors (L.S.)
The PeakTech 5086 allows for compensation of different light sources. There are 10 adjustable factors (L.S. 0 to L.S. 9).
- Naciśnij i przytrzymaj HOLD/L.S. button until "L.S." appears on the display, indicating you are in Light Source factor adjustment mode.
- Użyj W górę (▲) I W dół (▼) buttons to select one of the 10 factor memory locations (L.S. 0 to L.S. 9).
- Naciskać HOLD/L.S. again to enter the adjustment for the selected factor.
- Użyj W górę (▲) I W dół (▼) buttons to adjust the factor value. Consult the full manual or light source specifications for appropriate values.
- Naciskać HOLD/L.S. to confirm the setting and exit the adjustment mode.
6.5 Funkcja zatrzymania danych
- Podczas pomiaru naciśnij HOLD/L.S. button (short press) to freeze the current reading on the display. "HOLD" will appear.
- Naciskać HOLD/L.S. ponownie, aby zwolnić blokadę i wznowić pomiary na żywo.
6.6 Minimum, Maximum, and Average (AVG) Measurement
This function allows you to track the lowest, highest, and average light intensity over a measurement period.
- Naciśnij PAMIĘĆ/CZYTAJ button (short press) repeatedly to cycle through MIN, MAX, and AVG modes. The corresponding indicator will appear on the display.
- In MIN mode, the display shows the lowest reading recorded since entering the mode.
- In MAX mode, the display shows the highest reading recorded.
- In AVG mode, the display shows the average reading.
- To exit MIN/MAX/AVG mode, press the PAMIĘĆ/CZYTAJ button until no indicator is shown, or turn the device off and on again.
6.7 Memory Functions (Store/Recall)
The device can store up to 99 measurement values.
Storing a Measurement:
- With a live reading on the display, press and hold the PAMIĘĆ/CZYTAJ button until "MEM" flashes and a memory location number appears.
- Użyj W górę (▲) I W dół (▼) buttons to select an empty memory location (or overwrite an existing one).
- Naciskać PAMIĘĆ/CZYTAJ again to store the value. The display will briefly confirm storage.
Recalling Stored Measurements:
- Naciśnij PAMIĘĆ/CZYTAJ button (short press) repeatedly until "READ" appears on the display.
- Użyj W górę (▲) I W dół (▼) buttons to scroll through the stored memory locations.
- To exit recall mode, press PAMIĘĆ/CZYTAJ until "READ" disappears, or turn the device off and on.
7. Konserwacja
7.1 Czyszczenie
- Wipe the device and sensor with a soft, dry cloth.
- Nie należy używać środków czyszczących o właściwościach ściernych ani rozpuszczalników.
- Keep the sensor's light-receiving surface clean and free of dust or fingerprints for accurate readings.
7.2 Wymiana baterii
When the low battery indicator appears on the display, replace the batteries as described in Section 5.1. Always use fresh batteries of the specified type.
7.3 Przechowywanie
- When not in use, store the device in its carrying bag with the sensor cap in place.
- Przechowywać w chłodnym, suchym miejscu, z dala od bezpośredniego światła słonecznego i ekstremalnych temperatur.
- Remove batteries if storing for an extended period to prevent leakage.
8. Rozwiązywanie Problemów
| Problem | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| Urządzenie nie włącza się. | Rozładowane lub nieprawidłowo zainstalowane baterie. | Sprawdź biegunowość baterii i w razie potrzeby wymień baterie. |
| Niedokładne odczyty. | Dirty sensor, incorrect light source factor, or sensor cap still on. | Clean the sensor. Verify the correct light source factor is set. Ensure sensor cap is removed. Perform zero adjustment. |
| Na wyświetlaczu pojawia się komunikat „OL” (Przeciążenie). | Light intensity exceeds the measurement range. | Move the sensor away from the light source or use in a less intense environment. |
| Cannot store or recall data. | Pamięć jest pełna lub operacja jest nieprawidłowa. | Ensure you are following the correct steps for storing/recalling. If memory is full, consider overwriting old data or noting down critical values. |
9. Specyfikacje
| Funkcja | Szczegół |
|---|---|
| Wyświetlacz | 3 3/4 digit LCD (max. 3999) |
| Jednostki miary | Lux (lx), Footcandle (FC), Candela (cd) |
| Light Source Factors | 10 freely adjustable factors |
| Częstotliwość odświeżania | Około. 2.5 razy na sekundę |
| Typ czujnika | External sensor with cosine angle correction |
| Standard pomiarowy | JIS C 1609:1993 + CNS 5119 Class A |
| Funkcje | Data Hold, Min/Max/AVG, Auto Range, Zero Adjustment |
| Pamięć | 99 data storage locations |
| Źródło zasilania | Zawiera baterie) |
| Wymiary (pakiet) | Wymiary 21 x 14.3 x 6.7 cm |
| Waga (opakowanie) | 430 gramów |
| Numer modelu | Bl GEN 3C 0323 883 |
| ASIN | B017KMZ1H2 |
| EAN/UPC | 04250569403460 |
10. Gwarancja i wsparcie
PeakTech products are designed for reliability and performance. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or visit the official PeakTech webstrona.
Information regarding spare parts availability and software updates is not explicitly provided in the product details. For technical support or service inquiries, please contact your local PeakTech distributor or customer service department.
Ask a question about this manual