Wstęp
This manual provides detailed instructions for the safe and efficient operation of your WZRELB 3000W Pure Sine Wave Solar Power Inverter. This inverter is designed to convert 12V DC power from a battery source into 120V AC power at 60Hz, suitable for various off-grid applications, home power backup, and mobile power needs. Please read this manual thoroughly before installation and use to ensure proper function and safety.
Informacje dotyczące bezpieczeństwa
Ważne środki ostrożności:
- Do not connect the inverter with grid power.
- Reverse connection of positive and negative terminals is strictly forbidden and will cause damage to the unit and potential hazards.
- Zapewnij odpowiednią wentylację wokół falownika, aby zapobiec przegrzaniu.
- Trzymaj falownik z dala od wody, wilgoci i materiałów łatwopalnych.
- Always disconnect the battery before performing any maintenance or cleaning.
Cechy produktu
- 3000W continuous power, 6000W peak power pure sine wave output.
- Converts 12V DC to 120V AC, 60Hz frequency.
- Equipped with dual US outlets and a hardwire terminal for high-power appliances.
- Intelligent temperature-controlled cooling fan system.
- Earth connection for both PCB board and output for enhanced safety.
- Digital LED display for monitoring input and output voltage.
- High-quality true copper inductance for clean AC output.
- Built-in soft starter to reduce surge current impact and extend appliance lifespan.
- Multiple protection features: over voltage, over temperature, overload, short circuit, reverse polarity, and low voltagochrona.
Zawartość opakowania
Sprawdź, czy w przesyłce znajdują się wszystkie elementy:
- WZRELB 3000W Pure Sine Wave Inverter
- Instrukcja obsługi
- Bezpieczniki
- 2 Sets of 7AWG Cables (Red and Black)

Konfiguracja i instalacja
Proper installation is crucial for the safe and efficient operation of your inverter. This inverter is designed for off-grid systems only.
DC Input Connection (Battery)
Connect the inverter to your 12V battery system using the provided cables. Ensure connections are tight to prevent arcing and power loss.
- Remove the hardware (nut, lock washer, flat washer) from the inverter's DC input studs.
- Connect the red cable to the positive (+) terminal and the black cable to the negative (-) terminal. If using two cables per terminal, twist them together for a better connection before securing.
- Place the flat washer, then the lock washer, and finally tighten the nut securely.
- Podłącz pozostałe końce kabli do akumulatora 12 V, zwracając uwagę na prawidłową biegunowość.

Podłączenie wyjścia AC
The inverter provides dual US outlets and a hardwire terminal for AC output.
- For standard appliances, use the dual US outlets (15A Max).
- For high-power appliances, use the hardwire terminal (25A Max).
- When hardwiring, connect the yellow wire to GROUND, the black wire to NEUTRAL, and the red wire to HOT.
- After wiring, secure the plastic cover over the terminal block.

Grunt
Ensure the inverter is properly grounded. A grounding lug is located on the bottom of the unit. Connect a suitable ground wire from this lug to an appropriate earth ground.

Instrukcja wideo instalacji
For a visual guide on how to install and connect your inverter, please watch the following video:
Instrukcja obsługi
Once properly installed, operating the inverter is straightforward:
- Włączanie/wyłączanie: Use the main power switch on the front panel to turn the inverter on or off.
- Wyświetlacz LED: The digital LED display shows the input DC voltage and output AC voltage, allowing you to monitor the system's status.
- Podłączanie urządzeń: Plug your AC appliances into the outlets or connect them via the hardwire terminal. Ensure the total wattagliczba podłączonych urządzeń nie przekracza ciągłej mocy znamionowej falownika (3000 W).
- Zabezpieczenie przed przeciążeniem: The inverter has built-in overload protection. If an overload occurs, the inverter will shut down to prevent damage. Reduce the load and restart the inverter.
Rozważania dotyczące obciążenia
Different types of loads have different power requirements. For resistive loads (e.g., heaters, lights), choose an inverter with continuous power equal to or slightly higher than the appliance's rated power. For inductive loads (e.g., motors, compressors, refrigerators), the starting current can be 3-7 times higher than the running current. Select an inverter whose continuous power is 3-7 times higher than your inductive appliance's continuous power to handle the surge.

Użycie Examples
The WZRELB 3000W Pure Sine Wave Inverter is versatile and suitable for a wide range of applications:
- Systemy poza siecią: Ideal for solar power systems in remote cabins or homes.
- Kampery i Camping: Power your appliances, electronics, and tools while on the go.
- Kopia zapasowa awaryjna: Provides reliable power during outages for essential home appliances.
- Worksite Power: Run power tools and equipment where grid power is unavailable.


RV Power Integration Video
See how the WZRELB 3000W Pure Sine Wave Inverter can be integrated into an RV system to power various appliances:
Specyfikacje
| Funkcja | Specyfikacja |
|---|---|
| Marka | WZREŁB |
| Nazwa modelu | 300012FBA |
| Cotage (ciągły) | 3000 watów |
| Moc wyjściowa szczytowa | 6000 watów |
| Wejście Voltage | 12 woltów prądu stałego |
| Objętość wyjściatage | 120 V AC |
| Częstotliwość | 60 Hz |
| Kształt fali wyjściowej elektrycznej | Czysta fala sinusoidalna |
| Liczba gniazdek | 2 (US standard) |
| Typ wyświetlacza | Cyfrowy wyświetlacz LED |
| Pozycja Wymiary (dł. x szer. x wys.) | 17.72" x 9.45" x 3.54" |
| Waga przedmiotu | 5.2 kilograma |
| Źródło zasilania | Solar Powered (via battery connection) |
| Zalecane zastosowania | Vehicle, Off-Grid Systems |
| Energy Specifications Met | UL |
Rozwiązywanie problemów
If you encounter issues with your WZRELB inverter, consider the following common problems and solutions:
- Brak mocy wyjściowej: Sprawdź szczelność połączeń akumulatora i prawidłową biegunowość. Sprawdź pojemność akumulatora.tage is within the operating range (10V-15V DC). Ensure the inverter's power switch is ON.
- Wyłączenie przeciążeniowe: If the inverter shuts down, it may be due to an excessive load. Disconnect some appliances and restart the inverter. Refer to the Load Considerations section.
- Niska objętośćtage Alarm/Wyłączenie: This indicates the input DC voltage is too low (below 10.5V for alarm, below 9V for shutdown). Recharge or replace your battery.
- Wyłączenie z powodu nadmiernej temperatury: If the inverter becomes too hot, its internal protection will shut it down. Ensure adequate ventilation and clear any obstructions from the cooling fans. Allow the unit to cool down before restarting.
- Wentylator nie działa: The intelligent cooling fans activate based on internal temperature. If the inverter is cool or under light load, the fans may not run. If the inverter is hot and fans are not running, contact support.
Gwarancja i wsparcie
Your WZRELB 3000W Pure Sine Wave Solar Power Inverter comes with a 12-month warranty from the date of purchase, covering manufacturing defects. For technical support, troubleshooting assistance, or warranty claims, please contact WZRELB customer service. You can find more information and contact details on the WZRELB Store.