The Rems Multi-push SL is an advanced, compact electronic unit designed for efficient flushing, cleaning, disinfection, and pressure testing of pipe systems. Equipped with an oil-free compressor, it offers versatile applications including:

  • Flushing with water or a water/air mixture.
  • Disinfection and cleaning of piping systems.
  • Protection of piping systems.
  • Pressure testing with compressed air or water for pipe systems and tanks.
  • Use as a compressor for filling various tanks with compressed air and powering pneumatic tools.

This single device features over 10 automatic flushing and pressure testing programs, continuous process monitoring, intervention reporting, and a USB interface for data management.

2. Instrukcje bezpieczeństwa

Always observe general safety regulations and local guidelines when operating the Rems Multi-push SL. Failure to do so may result in injury or damage to the equipment.

  • Bezpieczeństwo elektryczne: Ensure the unit is connected to a properly grounded power supply. Do not operate with wet hands or in wet conditions. Disconnect power before performing any maintenance.
  • Bezpieczeństwo ciśnieniowe: Always wear appropriate personal protective equipment (PPE), such as safety glasses, when working with pressurized systems. Ensure all connections are secure before applying pressure. Do not exceed the maximum operating pressure specified for your piping system or the Rems Multi-push SL.
  • Postępowanie z chemikaliami: If using cleaning or disinfection agents, follow the manufacturer's safety data sheets (SDS) and wear appropriate PPE. Ensure proper ventilation.
  • Połączenia węży: Use only hoses and fittings rated for the intended pressure and temperature. Inspect hoses for damage before each use.
  • Dzieci i osoby nieupoważnione: Keep the unit out of reach of children and ensure only trained personnel operate the equipment.

3. Konfiguracja

Proper setup is crucial for safe and effective operation. Follow these steps to prepare your Rems Multi-push SL:

  1. Pozycjonowanie: Place the Rems Multi-push SL on a stable, level surface near the system to be serviced. Ensure adequate ventilation.
  2. Podłączenie zasilania: Connect the unit to a suitable electrical outlet (refer to the unit's label for voltage wymagania).
  3. Połączenia węży:
    • Connect the supply hose from the water source to the inlet of the Rems Multi-push SL.
    • Connect the outlet hose from the Rems Multi-push SL to the system being flushed or tested.
    • Sprawdź, czy wszystkie połączenia są szczelne i szczelne.
  4. Przygotowanie systemu: Prepare the piping system according to the specific task (e.g., draining, isolating sections).
Rems Multi-push SL connected to a complex pipe system for flushing or pressure testing.

Rysunek 1: The Rems Multi-push SL unit connected to a pipe manifold system. The yellow unit is on the floor, with hoses connecting it to the plumbing. A filter and various valves are visible in the pipework, indicating a setup for system maintenance or testing.

4. Instrukcja obsługi

The Rems Multi-push SL features an intuitive electronic control system. Refer to the display and control panel for program selection and monitoring.

  1. Włączanie: Switch on the main power button. The display will illuminate.
  2. Wybór programu: Use the navigation buttons to select the desired program from the available options (e.g., flushing, pressure test, disinfection). The unit offers over 10 automatic programs.
  3. Regulacja parametrów: For certain programs, you may need to adjust parameters such as pressure, duration, or flow rate. Follow the on-screen prompts.
  4. Rozpocznij operację: Press the START button to begin the selected program. The unit will automatically execute the process.
  5. Monitorowanie procesów: The display provides real-time information on the process status, pressure, and duration. The unit continuously monitors the process.
  6. Completion and Reporting: Upon completion, the unit will indicate the end of the program. You can generate intervention reports and transfer data via the USB interface.
  7. Compressor Function: To use the unit as a compressor, select the appropriate program. Connect the pneumatic tool or tank to be filled to the designated air outlet.

5. Konserwacja

Regular maintenance ensures the longevity and optimal performance of your Rems Multi-push SL.

  • Czyszczenie: Po każdym użyciu należy wyczyścić zewnętrzną część urządzenia za pomocąamp ściereczka. Nie należy używać środków czyszczących o właściwościach ściernych ani rozpuszczalników.
  • Kontrola węża: Regularly inspect all hoses for signs of wear, cracks, or damage. Replace damaged hoses immediately.
  • Konserwacja filtra: The system includes filters (visible in Figure 1). Check and clean or replace these filters as necessary to maintain optimal flow and prevent contamination. Refer to the detailed filter maintenance instructions in the comprehensive manual.
  • Składowanie: Store the unit in a dry, frost-free environment when not in use.

6. Rozwiązywanie Problemów

If you encounter issues with your Rems Multi-push SL, consult the following basic troubleshooting steps:

  • Urządzenie nie włącza się:
    • Check the power cable connection to both the unit and the electrical outlet.
    • Sprawdź, czy gniazdko elektryczne jest sprawne.
    • Check the unit's fuse, if accessible.
  • Low Pressure/Flow:
    • Ensure the water supply is adequate and all valves are fully open.
    • Check for kinks or blockages in the hoses.
    • Inspect and clean the filters.
    • Verify that the correct program and pressure settings are selected.
  • Komunikat o błędzie na wyświetlaczu:
    • Note the error code or message.
    • Refer to the comprehensive Rems Multi-push SL manual for specific error code explanations and solutions.
  • Nietypowy hałas:
    • Power off the unit immediately.
    • Sprawdź, czy nie ma luźnych elementów lub ciał obcych.
    • If the noise persists, contact Rems customer support.

For complex issues or repairs, always contact authorized Rems service personnel.

7. Specyfikacje

MarkaRems
Numer modelumulti-push
Waga przedmiotu39 kg (85.98 funta)
Źródło zasilaniaad_aria
Zalecane zastosowania produktuFlushing, Blowing
ASINB00FT2WEXU
Międzynarodowy kod artykułu04039976132091

8. Gwarancja i wsparcie

For detailed warranty information, please refer to the documentation included with your Rems Multi-push SL unit or visit the official Rems website. For technical support, service, or spare parts, please contact your authorized Rems dealer or Rems customer service directly.

Producent: Rems

Powiązane dokumenty - multi-push

Przedview REMS Multi-Push SL / SLW Betriebsanleitung
Offizielle Betriebsanleitung für die elektronische Spül- und Druckprüfeinheit REMS Multi-Push SL und SLW. Umfassende Informationen zu Installation, Sicherheit, Betrieb und Wartung.
Przedview Instrukcja obsługi REMS Multi-Push SL / SLW
Instrukcja obsługi systemów REMS Multi-Push SL i SLW zawierająca szczegółowe informacje na temat obsługi, bezpieczeństwa i danych technicznych, łącznie z tabelą objętości i indeksem języków.
Przedview REMS Push / REMS Push INOX Hand Pressure Testing Pump Instruction Manual
Comprehensive instruction manual for the REMS Push and REMS Push INOX hand pressure testing pumps. Includes safety guidelines, technical specifications, and operating procedures for pipe system leak testing.
Przedview Lista części zamiennych i schematy REMS Solar-Push I80/K60
This document provides a comprehensive spare parts list and component diagrams for the REMS Solar-Push I80 and K60 pumps. It includes detailed part descriptions in German, English, French, and Italian, along with corresponding part numbers and assembly references.
Przedview REMS E-Push 2 Electric Pressure Testing Pump Instruction Manual
Official instruction manual for the REMS E-Push 2 electric pressure testing pump. Includes safety warnings, technical specifications, and operating instructions for professional use.
Przedview ROLLER'S Multi-Control SL/SLW: Versatile Flushing, Filling, and Testing Technology
Discover the ROLLER'S Multi-Control SL and SLW units, powerful electronic flushing and pressure testing systems with oil-free compressors. Ideal for drinking water, heating systems, and more, offering disinfection, cleaning, and pneumatic tool operation capabilities.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.