Bachmann 852.9821

Bachmann 852.9821 Energy Meter User Manual

Model: 852.9821 | Brand: Bachmann

1. Wprowadzenie i koniecview

This manual provides comprehensive instructions for the safe and efficient use of your Bachmann 852.9821 Energy Meter. This device is designed to measure and display the energy consumption of connected electrical appliances. It features a large LCD with a blue backlight for clear readability, displaying various electrical parameters and supporting two separate tariff rates for accurate cost calculation.

Bachmann 852.9821 Energy Meter front view z wyświetlaczem i przyciskami

Rysunek 1: Przód view of the Bachmann 852.9821 Energy Meter, showing the digital display, control buttons (MENU, SET, arrow buttons, RST), and the integrated power socket. The display shows time and energy consumption in kWh.

2. Instrukcje bezpieczeństwa

Please read these safety instructions carefully before using the device. Failure to follow these instructions may result in electric shock, fire, or damage to the device.

  • Nie otwierać urządzenia casing. Wewnątrz nie ma żadnych części nadających się do samodzielnej naprawy przez użytkownika.
  • Nie wystawiaj urządzenia na działanie wilgoci, deszczu i ekstremalnych temperatur.
  • Upewnij się, że urządzenie jest podłączone do prawidłowo uziemionego gniazdka elektrycznego.
  • Do not overload the device. The maximum load is 3680 W (16 A at 230 V).
  • Trzymać poza zasięgiem dzieci. Urządzenie posiada funkcje zabezpieczające przed dziećmi.
  • If the device is damaged, discontinue use immediately and contact qualified personnel for repair.
  • Clean the device only with a dry, soft cloth. Do not use liquid cleaners.

3. Funkcje produktu

The Bachmann 852.9821 Energy Meter offers the following key features:

  • Large LCD screen with blue backlight for easy reading.
  • Displays various electrical parameters: Voltage (V), Frequency (Hz), Active Power (W), Apparent Power (VA).
  • Records total energy consumption in kWh.
  • Supports two separate tariff rates for precise cost calculation.
  • Integrated timer function.
  • Szeroka objętośćtage range: 160 V - 280 V.
  • Power measurement range: 4 W - 3680 W.
  • Low self-consumption: Less than 1 W.
  • Equipped with child protection.

4. Konfiguracja

Setting up your energy meter is a straightforward process:

  1. Rozpakować: Carefully remove the energy meter from its packaging.
  2. Włączać do kontaktu: Insert the energy meter into a standard 230V AC wall socket. The display should illuminate.
  3. Podłącz urządzenie: Podłącz urządzenie, które chcesz monitorować, do gniazda znajdującego się z przodu licznika energii.
  4. Ustawienia początkowe: Upon first use or after a reset, you may need to set the current time and tariff rates. Refer to the "Operating Instructions" section for details on navigating the menu.

5. Instrukcja obsługi

The energy meter is controlled using the buttons located below the display.

  • Przycisk MENU: Press to cycle through different display modes (e.g., Voltage, Current, Power, Frequency, Cost, Total kWh).
  • Przycisk SET: Used to enter settings mode for time, date, and tariff rates. Press again to confirm selections.
  • Przyciski strzałek ( I +): Used to navigate through options or adjust values within settings mode. The button typically moves between settings, while the + button increases values.
  • Przycisk RST: A small recessed button (often requiring a pen tip to press) used to reset all accumulated data and settings to factory defaults. Use with caution.

5.1. Ustawianie czasu i daty

  1. Naciśnij i przytrzymaj USTAWIĆ Naciskaj przycisk, aż wyświetlacz czasu zacznie migać.
  2. Użyj button to select the hour, minute, day, month, and year.
  3. Użyj + przycisk, aby dostosować migającą wartość.
  4. Naciskać USTAWIĆ aby potwierdzić każde ustawienie i przejść do następnego.
  5. Naciskać MENU aby wyjść z trybu ustawień.

5.2. Setting Tariff Rates

The device supports two tariff rates (Tariff 1 and Tariff 2) for calculating electricity costs.

  1. Naciśnij MENU button repeatedly until the cost display mode is shown.
  2. Naciśnij i przytrzymaj USTAWIĆ button until the tariff rate flashes.
  3. Użyj button to select Tariff 1 or Tariff 2.
  4. Użyj + button to adjust the cost per kWh for the selected tariff.
  5. Naciskać USTAWIĆ to confirm and save the tariff rate.
  6. Naciskać MENU aby wyjść z trybu ustawień.

6. Wyświetlanie informacji

The LCD provides various readings. Press the MENU button to cycle through the following displays:

  • Czas i data: Aktualny czas i data.
  • Tomtage (v): Wyświetla aktualną głośność liniitage (np. 230 V).
  • Częstotliwość (Hz): Shows the current power line frequency (e.g., 50Hz).
  • Moc czynna (W): The real power consumed by the connected appliance.
  • Apparent Power (VA): The total power in an AC circuit, including reactive power.
  • Współczynnik mocy: The ratio of active power to apparent power.
  • Całkowita energia (kWh): Accumulated energy consumption in kilowatt-hours.
  • Koszt: Calculated cost based on accumulated kWh and set tariff rates.
  • Czas działania: Total time the appliance has been connected and drawing power.

7. Konserwacja

The Bachmann 852.9821 Energy Meter requires minimal maintenance.

  • Czyszczenie: Przed czyszczeniem odłącz urządzenie od zasilania. Do czyszczenia obudowy użyj miękkiej, suchej ściereczki. Nie używaj środków czyszczących o właściwościach ściernych ani rozpuszczalników.
  • Składowanie: Jeśli urządzenie nie będzie używane przez dłuższy czas, należy je przechowywać w chłodnym i suchym miejscu, z dala od bezpośredniego światła słonecznego i ekstremalnych temperatur.

8. Rozwiązywanie Problemów

If you encounter issues with your energy meter, refer to the following troubleshooting guide:

ProblemMożliwa przyczynaRozwiązanie
Wyświetlacz jest pusty.Brak zasilania.Ensure the meter is securely plugged into a live wall socket. Check the wall socket with another appliance.
Nieprawidłowe odczyty.Improper settings or device malfunction.Verify tariff settings. If issues persist, perform a factory reset using the RST button.
Przyciski nie reagują.Tymczasowy błąd oprogramowania.Unplug the device from the wall socket, wait 10 seconds, then plug it back in.
Appliance not receiving power.Meter malfunction or appliance issue.Test the appliance directly in the wall socket. If the appliance works, the meter may be faulty.

9. Specyfikacje techniczne

Below are the technical specifications for the Bachmann 852.9821 Energy Meter:

  • Numer modelu: 852.9821
  • Marka: Bachmann
  • Kolor: Biały
  • Tomtage Zakres: 160 V - 280 V prądu przemiennego
  • Objętość nominalnatage: 230 wolty
  • Max. Power Load: 3860 W (16 A)
  • Min. Power Measurement: 4 watów
  • Zużycie własne: < 1 W
  • Wymiary (dł. x szer. x wys.): 21.2 x 9.2 x 7.6 cm (8.35 x 3.62 x 2.99 cala)
  • Waga: 230 gramów
  • System miar: Metryczny
  • Cechy: Large LCD with blue backlight, 2 separate tariff rates, child protection.
Dimensional drawing of the Bachmann 852.9821 Energy Meter

Rysunek 2: Dimensional drawing of the Bachmann 852.9821 Energy Meter, illustrating its length (133mm), width (71mm), and height (37mm) for precise installation planning.

10. Gwarancja i wsparcie

Bachmann products are manufactured to high-quality standards. For information regarding warranty coverage, please refer to the warranty card included with your purchase or visit the official Bachmann webstrona.

For technical support, troubleshooting assistance beyond this manual, or spare parts inquiries, please contact Bachmann customer service through their official channels.