AmScope M158C-2L

AmScope M158C-2L Cordless Compound Monocular Microscope User Manual

Model: M158C-2L

1. Koniec produktuview

The AmScope M158C-2L is a versatile cordless compound monocular microscope designed for biological and educational applications. It features interchangeable WF10x and WF25x eyepieces, providing a magnification range from 40x to 1000x. The microscope is equipped with both upper (episcopic) and lower (diascopic) LED illumination, controlled by a rheostat for adjustable brightness. Its robust design includes coaxial coarse and fine focus knobs, a single-lens condenser, and a plain stage z stage clips. This model can be powered by a 110V AC adapter or three AA batteries, offering flexibility for both lab and field use.

AmScope M158C-2L Cordless Compound Monocular Microscope

Figure 1: AmScope M158C-2L Cordless Compound Monocular Microscope. This image displays the full microscope unit, including the monocular head, objective lenses, stage, focus knobs, and power adapter.

2. Informacje dotyczące bezpieczeństwa

  • Always handle the microscope with care to prevent damage to optical and mechanical components.
  • Upewnij się, że mikroskop jest umieszczony na stabilnej i równej powierzchni, aby zapobiec jego przewróceniu.
  • Do not expose the microscope to extreme temperatures, humidity, or direct sunlight.
  • Disconnect the power adapter before cleaning or performing any maintenance.
  • Use only the specified power adapter (110V) or AA batteries.
  • Małe części i akcesoria należy trzymać z dala od dzieci, aby zapobiec ryzyku zadławienia.
  • Avoid touching optical surfaces with bare hands. Use a lens cleaning cloth if necessary.

3. Co znajduje się w pudełku

Sprawdź, czy w Twoim pakiecie znajdują się wszystkie wymienione poniżej elementy:

  • AmScope M158C-2L microscope with plain stage
  • WF10x eyepiece
  • WF25x eyepiece
  • 4x DIN achromatic objective
  • 10x DIN achromatic objective
  • 40x DIN achromatic objective
  • (2) Stage klipy
  • Osłona przeciwpyłowa
  • Zasilacz 110V
  • Instrukcje (niniejsza instrukcja)

4. Konfiguracja

4.1 Rozpakowywanie i umieszczanie

  1. Ostrożnie wyjąć wszystkie elementy z opakowania.
  2. Mikroskop należy ustawić na stabilnej, równej i wolnej od wibracji powierzchni.
  3. Zdejmij osłonę przeciwpyłową z mikroskopu.

4.2 Eyepiece Installation

  1. Gently insert either the WF10x or WF25x eyepiece into the monocular viewrurka.
  2. Ensure the eyepiece is fully seated.

4.3 Połączenie zasilania

The microscope can be powered by the included AC adapter or by three AA batteries (sold separately).

  • Zasilanie prądem zmiennym: Connect the 110V power adapter to the microscope's power input jack and then plug it into a standard electrical outlet.
  • Moc baterii: Locate the battery compartment on the base of the microscope. Insert three AA batteries, ensuring correct polarity. Close the battery compartment cover securely.

5. Instrukcja obsługi

5.1 Przygotowanie próbki

  1. Place your prepared slide or specimen on the plain stage.
  2. Zabezpiecz zamek za pomocą stagklipy elektroniczne.
  3. For opaque specimens, ensure the upper LED illumination is positioned correctly. For translucent specimens, ensure the lower LED illumination is clear.
User placing a specimen slide on the microscope stage

Figure 2: User placing a specimen slide on the microscope stage. This image illustrates the proper method for securing a slide using the stage clips on the plain stage.

5.2 Selecting Magnification

  1. Rotate the revolving nosepiece to select the desired objective lens (4x, 10x, or 40x). Start with the lowest magnification (4x) for initial viewing.
  2. The total magnification is calculated by multiplying the eyepiece magnification by the objective lens magnification (e.g., WF10x eyepiece with 40x objective = 400x total magnification).

5.3 Regulacja oświetlenia

The microscope features both upper (episcopic) and lower (diascopic) LED illumination.

  • Lower Illumination (Brightfield): Used for translucent or transparent specimens. Turn on the lower LED light source. Adjust the light intensity using the rheostat control knob located on the base. The disc diaphragm below the stage can be rotated to control the amount of light passing through the specimen.
  • Upper Illumination (Incidental): Used for opaque specimens that do not allow light to pass through. Turn on the upper LED light source. Adjust the light intensity using the rheostat control knob.

5.4 Ustawianie ostrości

  1. With the lowest power objective (4x) in place, use the coarse focus knob (larger knob) to bring the specimen into approximate focus.
  2. Once roughly focused, use the fine focus knob (smaller knob, nested with coarse focus) for precise focusing and to achieve a sharp image.
  3. When switching to higher magnification objectives, only minor adjustments with the fine focus knob should be necessary due to the parfocal design.

5.5 Demonstracja wideo

Video 1: AmScope M158C-2L Cordless Compound Monocular Microscope Overview. This video provides a visual demonstration of the microscope's features, including its high-quality optics, dual illumination system for opaque and transparent specimens, and precision focusing capabilities.

6. Konserwacja

  • Czyszczenie soczewek: Use a soft, lint-free lens cleaning cloth and a small amount of lens cleaning solution. Wipe gently in a circular motion. Avoid using abrasive materials or harsh chemicals.
  • Czyszczenie ciała: Przetrzyj korpus mikroskopu miękką,amp szmatką. Nie stosować rozpuszczalników organicznych.
  • Składowanie: When not in use, cover the microscope with the provided dust cover and store it in a cool, dry place away from direct sunlight and dust.
  • Wymiana baterii: If using battery power, replace all three AA batteries when the illumination dims significantly. Ensure correct polarity.

7. Rozwiązywanie Problemów

ProblemMożliwa przyczynaRozwiązanie
Brak oświetleniaPower adapter not connected, batteries dead/incorrectly inserted, power switch off.Check power adapter connection, replace batteries, ensure power switch is on.
Image blurry/cannot focusIncorrect objective selected, coarse/fine focus not adjusted, slide upside down, dirty lens.Start with lowest objective, use coarse then fine focus, ensure slide is correct side up, clean lenses.
Ciemne pole viewDiaphragm closed too much, illumination too low, objective not fully clicked into place.Adjust diaphragm, increase rheostat intensity, rotate nosepiece until objective clicks.
Dust/spots in viewKurz na okularze lub obiektywie.Clean eyepiece and objective lenses carefully.

8. Specyfikacje

FunkcjaSzczegół
GłowaCompound monocular, 45-degree fixed inclination, 360-degree rotatable
OkularyWF10x, WF25x
Cele4x, 10x, 40x DIN achromatic
Zakres powiększenia40x-1000x
StageZwykłytage z stage klipy
Konfiguracja oświetleniaIncidental (upper) and Transmitted (lower)
SkraplaczSingle lens, 0.65 NA
MembranaDisc diaphragm
Źródło światłaLED with rheostat control
Typ oświetleniaJasne pole
SkupienieCoaxial coarse and fine focus
Moc110V/60Hz AC adapter or three AA batteries
Wymiary produktu10.24 x 6.69 x 14.96 cala
Waga przedmiotu4.8 funta
TworzywoMetal

9. Gwarancja i wsparcie

United Scope (AmScope) products are designed for durability and precision. While specific warranty details are typically provided with the product documentation, AmScope generally offers a 5-year warranty on their microscopes, covering manufacturing defects.

For technical support, warranty claims, or replacement parts, please contact AmScope customer service directly. Refer to the contact information provided on the official AmScope webmiejscu lub w oryginalnym opakowaniu produktu.

Producent: AmScope

Siedziba: Irvine, CA, USA

© 2025 AmScope. All rights reserved.