Johnson Controls P70AA-118C

Johnson Controls P70AA-118C Condenser Fan Cycling Control

Model: P70AA-118C | Marka: Kontrole Johnsona

1. Wprowadzenie i koniecview

The Johnson Controls P70AA-118C is a robust pressure control designed for commercial refrigeration and air conditioning applications. Its primary functions include high pressure cut-out control, head-pressure control, and condenser fan cycling. This control is compatible with most common non-corrosive refrigerants and can also be utilized in other non-corrosive fluid applications. It features a single-pole, single-throw (SPST) switch configuration and is designed for a pressure range of 100 to 400 psi.

Johnson Controls P70AA-118C control unit, packaging, and mounting bracket.

Figure 1: Johnson Controls P70AA-118C control unit, packaging, and mounting bracket.

The P70AA-118C control unit and its dedicated mounting bracket.

Figure 2: The P70AA-118C control unit and its dedicated mounting bracket.

2. Główne cechy

  • Koperta i pokrywa wykonane w całości ze stali: Provides long-lasting, rugged protection for internal components, ensuring durability in demanding environments.
  • Regulacja ciśnienia skalibrowanego za pomocą celownika: Features a visible pressure scale that is fully adjustable through the range without requiring removal of the cover (on NEMA 1 enclosure models), simplifying setup.
  • Opcja ręcznego resetowania blokady: Offers a trip-free lockout mechanism that prevents overriding or resetting until the pressure returns to the specified safe level, enhancing system safety.
  • Variety of available pressure connection styles: Allows for greater flexibility during mounting and adaptation of pressure connections to various field application requirements.
Close-up of the control's front panel, showing the pressure adjustment scale and differential settings.

Figure 3: Close-up of the control's front panel, showing the pressure adjustment scale and differential settings.

3. Specyfikacje

SpecyfikacjaWartość
Numer modeluP70AA-118C
MarkaKontrole Johnsona
Zakres ciśnieniaod 100 do 400 psi
Długość kapilary36 cali
Flare Nut Size1/4 cala
Typ przełącznikaSingle-Pole, Single-Throw (SPST)
TworzywoStal
Waga przedmiotu1.49 funtów
Wymiary produktu10.25 x 2.75 x 4.37 cala
Typ wyświetlaczaAnalog
ProducentKontrole Johnsona
Data pierwszej dostępności11 października 2012 r.
Detailed product label from the packaging, showing specifications including pressure range, differential, and capillary length.

Figure 4: Detailed product label from the packaging, showing specifications including pressure range, differential, and capillary length.

4. Instalacja

Installation of the P70AA-118C control should be performed by a qualified HVAC technician or electrician in accordance with all local and national electrical codes. Ensure the power supply to the system is disconnected before beginning any installation work.

4.1 Montaż

Mount the control unit in a location that is easily accessible for adjustments and maintenance, yet protected from physical damage and excessive vibration. Use the provided mounting bracket and appropriate fasteners to secure the unit firmly.

Spód view of the P70AA-118C control unit, showing mounting points and electrical conduit entry.

Rysunek 5: Spód view of the P70AA-118C control unit, showing mounting points and electrical conduit entry.

4.2 Capillary Tube Connection

Carefully route the 36-inch capillary tube to the desired pressure sensing point. Avoid sharp bends or kinks that could damage the tube. Connect the 1/4 inch flare nut to the system's pressure port, ensuring a tight, leak-free seal. Do not overtighten.

Kątowy view of the P70AA-118C control, highlighting the capillary tube connection.

Rysunek 6: Kątowy view of the P70AA-118C control, highlighting the capillary tube connection.

Detail of the capillary tube and 1/4 inch flare nut connection.

Figure 7: Detail of the capillary tube and 1/4 inch flare nut connection.

4.3 Okablowanie elektryczne

Refer to the wiring diagram provided with the control unit or the system's specific schematics. Connect the electrical wiring to the appropriate terminals within the control's enclosure. Ensure all connections are secure and properly insulated. The P70AA-118C is a single-pole, single-throw (SPST) control.

5. Instrukcja obsługi

Once installed and wired, the P70AA-118C control can be adjusted to the desired operating parameters. The control features a sight-set calibrated pressure adjustment for easy setting.

5.1 Setting Pressure Range

The control allows for adjustment of both the cut-out (high pressure limit) and the differential (the difference between cut-in and cut-out pressures). Use a flat-head screwdriver to adjust the set points visible through the window on the front panel. The scale indicates the pressure in PSI.

5.2 Manual Reset Lockout

If the control is equipped with a manual reset lockout, it will trip and lock the system off if the pressure exceeds a critical threshold. To reset, the pressure must return to a safe level, and then the manual reset button must be pressed. This feature prevents automatic restarts under unsafe conditions.

6. Konserwacja

Regular maintenance ensures the longevity and reliable operation of your Johnson Controls P70AA-118C unit. Perform the following checks periodically:

  • Kontrola wizualna: Check the control unit, capillary tube, and electrical connections for any signs of wear, corrosion, or damage.
  • Czystość: Keep the control unit clean and free from dust, dirt, and debris, which can affect performance.
  • Integralność połączenia: Ensure all electrical and pressure connections remain tight and secure.
  • Kontrola funkcjonalności: Periodically verify that the control is cycling the fan or cutting out at the set pressure points as expected.

7. Rozwiązywanie Problemów

If you encounter issues with your P70AA-118C control, consider the following common troubleshooting steps. For complex issues, always consult a qualified technician.

  • Control Not Cycling Fan:
    • Verify power supply to the control.
    • Check pressure settings; ensure they are within the system's operating range and the control's capabilities.
    • Inspect capillary tube for kinks or leaks.
    • Check electrical connections for looseness or corrosion.
  • Niedokładne odczyty ciśnienia:
    • Ensure the capillary tube is properly connected and not damaged.
    • Verify the system's actual pressure with a calibrated gauge.
  • Control Trips Frequently:
    • Check for system overpressure conditions.
    • Review the set pressure and differential settings.
    • If equipped, ensure the manual reset lockout is not being triggered by transient pressure spikes.

8. Gwarancja i wsparcie

For detailed warranty information, please refer to the official documentation provided by Johnson Controls at the time of purchase or visit the Johnson Controls official website. Support for the P70AA-118C control can be obtained through authorized distributors or by contacting Johnson Controls customer service directly.

Product packaging label displaying the model number P70AA-118C and barcode.

Figure 8: Product packaging label displaying the model number P70AA-118C and barcode (UCC/EAN Code 128: 1078502829326).

Manufacturing origin label on the control unit, indicating 'ASSEMBLED IN MEXICO'.

Figure 9: Manufacturing origin label on the control unit, indicating 'ASSEMBLED IN MEXICO'.

© 2023 Johnson Controls. All rights reserved. This manual is for informational purposes only.

Powiązane dokumenty - P70AA-118C

Przedview Sterowniki wysokiego ciśnienia Johnson Controls serii P70, P72, P170
Szczegółowe ponadview Elektromechanicznych regulatorów ciśnienia serii PENN P70, P72 i P170 firmy Johnson Controls do zastosowań wysokociśnieniowych. Zawiera funkcje, zastosowania, tabele doboru i odnośniki do systemów chłodniczych i HVAC.
Przedview Johnson Controls Series 100 Single Package Units: Engineering Guide
Comprehensive engineering guide for Johnson Controls Series 100 Single Package Units, covering capacities from 70 to 105 tons. Details features, benefits, application data, nomenclature, and technical specifications for these energy-efficient HVAC units.
Przedview Pomoc dotycząca narzędzia sterującego Johnson Controls dla systemów HVAC
Ten kompleksowy dokument pomocy zawiera szczegółowe wskazówki dotyczące narzędzia Johnson Controls Controller Tool, obejmujące konfigurację, symulację, uruchomienie i rozwiązywanie problemów z systemami VAV Single Duct oraz innymi aplikacjami HVAC. Pomaga on specjalistom w efektywnym zarządzaniu systemami automatyki budynkowej.
Przedview Instrukcja instalacji zestawu akcesoriów: Zestaw okablowania zasilania trójfazowego z jednym punktem dla produktów w opakowaniach
Instrukcja instalacji zestawów akcesoriów do trójfazowego okablowania jednopunktowego firmy Johnson Controls, przeznaczonych do stosowania z produktami w obudowach PHE4, PCE4, PHE6 i PCE6 z ogrzewaniem elektrycznym. Zawiera szczegółowe tabele zgodności modeli, tom 1.tage, heater kits, wiring kits, and fuse sizes, along with installation instructions and wiring diagrams.
Przedview Instrukcja obsługi: Zewnętrzny system klimatyzacji typu split i pompa ciepła
Kompleksowa instrukcja obsługi zewnętrznych systemów klimatyzacji typu split i pomp ciepła Johnson Controls Ducted Systems, obejmująca kwestie dotyczące obsługi, wytycznych dotyczących bezpieczeństwa, funkcji systemu, konserwacji, rozwiązywania problemów oraz informacje na temat ograniczonej gwarancji.
Przedview Johnson Controls Seria 100 Jednostki Pakietowe Pojedyncze Przewodnik Inżynieryjny
Kompleksowy poradnik inżynieryjny dla urządzeń Johnson Controls serii 100 w pojedynczych pakietach (70-130 ton). Szczegółowe informacje o funkcjach, danych dotyczących zastosowań, specyfikacjach fizycznych i danych dotyczących wydajności chłodzenia dla wydajnych rozwiązań HVAC.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.