AmScope D120A-MS

AmScope D120A-MS Dual-View Instrukcja obsługi złożonego mikroskopu monokularowego

Model: D120A-MS

1. Wprowadzenie

The AmScope D120A-MS is a dual-view compound monocular microscope designed for high magnification observation in biological and educational applications. It features a versatile viewing head, multiple objective lenses, Brightfield illumination, and a mechanical stage for precise specimen manipulation. This manual provides essential information for the proper setup, operation, and maintenance of your microscope.

2. Wytyczne bezpieczeństwa

  • Zawsze obchodź się z mikroskopem ostrożnie. Unikaj gwałtownych ruchów i uderzeń.
  • Upewnij się, że mikroskop jest umieszczony na stabilnej i równej powierzchni, aby zapobiec jego przewróceniu.
  • Connect the power cord to a grounded electrical outlet of the correct voltage (110 V).
  • Do not touch optical surfaces with bare hands. Use lens paper or a soft, lint-free cloth for cleaning.
  • Unplug the microscope from the power source before cleaning or performing any maintenance.
  • Keep the microscope away from direct sunlight, high temperatures, dust, and corrosive chemicals.
  • Supervise children or inexperienced users to ensure safe operation.

3. Zawartość opakowania

Ostrożnie rozpakuj wszystkie elementy i sprawdź, czy w zestawie znajdują się następujące elementy:

  • AmScope D120A-MS microscope with mechanical stage
  • WF10x eyepiece
  • WF16x eyepiece
  • 4x DIN achromatic objective
  • 10x DIN achromatic objective
  • 40xS DIN achromatic objective (spring-loaded)
  • 100xS (oil) DIN achromatic objective (spring-loaded)
  • (2) Color filters
  • Zapasowa żarówka
  • Osłona przeciwpyłowa
  • Instrukcja obsługi (ten dokument)

4. Identyfikacja komponentów

Familiarize yourself with the main parts of your AmScope D120A-MS microscope:

AmScope D120A-MS Dual-View Złożony mikroskop monokularowy

Rysunek 4.1: Nadview of the AmScope D120A-MS microscope. This image displays the complete microscope assembly, including the base, stage, objective lenses, and dual-view monocular head.

  • Okular (Okulary): Gdzie patrzysz view the specimen. The D120A-MS includes WF10x and WF16x eyepieces.
  • Jednooczny Viewing Szef: The upper part of the microscope containing the eyepiece tube. This model features a dual-view head with a fixed 45-degree inclined tube and a vertical port.
  • Obrotowa końcówka: Uchwyt do mocowania soczewek obiektywowych i łatwa zmiana powiększenia.
  • Soczewki obiektywowe: The primary magnification components (4x, 10x, 40xS, 100xS oil).
  • Mechaniczny Stage: A platform where the specimen slide is placed, with controls for precise X-Y movement.
  • Stage Klipy: Secure the specimen slide on the mechanical stage.
  • Pokrętło regulacji ostrości: Large knob for rapid focusing adjustments.
  • Pokrętło precyzyjnej regulacji ostrości: Small knob for precise focusing adjustments.
  • Oświetlacz (źródło światła): Znajduje się pod stage, provides light for viewing. This model uses variable-intensity tungsten illumination.
  • Kondensator Abbego: Located below the stage, focuses light onto the specimen. Features a 1.25 NA and an iris diaphragm.
  • Przesłona tęczówkowa: Controls the amount of light passing through the specimen.
  • Opierać: The stable bottom support of the microscope.

5. Montaż i konfiguracja

Follow these steps to set up your microscope for initial use:

  1. Rozpakowywanie: Carefully remove the microscope and all accessories from the packaging. Retain the original packaging for future transport or storage.
  2. Umieszczenie: Place the microscope on a sturdy, level surface, away from vibrations and direct sunlight.
  3. Montaż okularu: Insert the desired eyepiece (WF10x or WF16x) into the inclined eyepiece tube of the monocular head. Gently twist to secure it.
  4. Cel instalacji: The objective lenses are typically pre-installed. If not, carefully screw each objective into the revolving nosepiece in increasing order of magnification (4x, 10x, 40xS, 100xS). Ensure they are finger-tight.
  5. Close-up of AmScope D120A-MS objective lenses

    Rysunek 5.1: Z bliska view of the objective lenses mounted on the revolving nosepiece. This image shows the 4x, 10x, 40xS, and 100xS (oil) objectives in position.

  6. Podłączenie zasilania: Connect the power cord to the microscope's power input and then to a standard 110V electrical outlet.
  7. Osłona przeciwpyłowa: When not in use, cover the microscope with the provided dust cover to protect it from dust and debris.

6. Podstawowa obsługa

This section outlines the fundamental steps for observing specimens with your microscope.

  1. Włączanie: Flip the power switch located on the base of the microscope. The illuminator should light up.
  2. Dostosuj oświetlenie: Use the variable intensity control knob to set the desired brightness. Adjust the iris diaphragm on the Abbe condenser to optimize contrast and resolution for your specimen.
  3. Umieść próbkę: Rotate the revolving nosepiece to select the lowest power objective (4x). Lower the mechanical stage using the coarse focus knob. Place a prepared specimen slide onto the mechanical stagi zabezpiecz go za pomocą stagklipy elektroniczne.
  4. Position Specimen: Użyj XYtage control knobs to move the slide until the area of interest is centered under the objective lens.
  5. Skupienie:
    • While looking through the eyepiece, slowly raise the stage używając pokrętło do zgrubnego ustawiania ostrości until the specimen comes into rough focus.
    • Użyj pokrętło precyzyjnego ustawiania ostrości aby uzyskać ostry i wyraźny obraz.
  6. Zmień powiększenie: Once focused at low power, rotate the revolving nosepiece to switch to a higher power objective (e.g., 10x, 40xS). Due to the parfocal design, only minor adjustments with the fine focus knob should be needed to bring the image back into sharp focus.
  7. Using the 100xS Oil Immersion Objective:
    • After focusing with the 40xS objective, rotate the nosepiece halfway between the 40xS and 100xS objectives.
    • Place a small drop of immersion oil directly onto the center of the specimen slide where the light passes through.
    • Carefully rotate the 100xS objective into the oil drop until it clicks into place. The objective should be immersed in the oil.
    • Używaj tylko pokrętło precyzyjnego ustawiania ostrości to bring the image into sharp focus. Do not use the coarse focus knob with the 100xS objective.
    • After use, clean the 100xS objective and the slide immediately with lens paper moistened with lens cleaning solution to remove all immersion oil.
  8. Podwójny-View Funkcjonalność: The vertical port on the monocular head can accept a second eyepiece for simultaneous viewing by another person or a camera mount for digital image capture (eyepiece and camera sold separately). Dioptric adjustment on the upright tube accommodates individual eye-strength differences.
  9. AmScope D120A-MS microscope connected to a laptop for digital imaging

    Rysunek 6.1: The AmScope D120A-MS microscope demonstrating its digital image capture capability by connecting to a laptop. This setup utilizes the vertical port for a camera attachment.

7. Konserwacja i pielęgnacja

Właściwa konserwacja gwarantuje długowieczność i optymalną pracę mikroskopu.

  • Czyszczenie soczewek: Use only specialized lens paper and lens cleaning solution for optical surfaces. Gently wipe in a circular motion. Never use abrasive cloths or harsh chemicals.
  • Ogólne sprzątanie: Przetrzyj korpus mikroskopu miękką,amp szmatką. Unikaj dostania się wilgoci do podzespołów elektrycznych.
  • Składowanie: Always cover the microscope with the dust cover when not in use. Store it in a dry, dust-free environment.
  • Wymiana żarówki: If the illuminator bulb burns out, unplug the microscope. Refer to the base of the microscope for access to the bulb compartment. Carefully replace the old bulb with the provided spare bulb, ensuring not to touch the glass part of the new bulb with bare hands.
  • Części mechaniczne: Do not attempt to lubricate or disassemble any mechanical parts. If issues arise, contact customer support.

8. Rozwiązywanie Problemów

W tej sekcji omówiono typowe problemy, na które możesz natrafić.

ProblemMożliwa przyczynaRozwiązanie
Brak oświetleniaPower cord disconnected, power switch off, bulb burnt outCheck power connection, turn on switch, replace bulb
Obraz jest rozmazany lub nieostryIncorrect focus adjustment, objective not fully engaged, dirty lensAdjust coarse/fine focus, rotate nosepiece until objective clicks, clean lenses
Ciemne pole viewIris diaphragm closed, illuminator too dim, condenser too lowOpen iris diaphragm, increase illuminator brightness, adjust condenser height
Kurz lub plamy w viewDust on eyepiece, objective, or slideClean eyepiece, objective, or slide with lens paper
Cannot focus at 100xNo immersion oil, air bubbles in oil, coarse focus usedApply immersion oil, remove air bubbles, use only fine focus

9. Specyfikacje techniczne

Detailed specifications for the AmScope D120A-MS microscope:

  • Głowa: Compound dual-view monocular, 45-degree inclined, 360-degree rotatable
  • Okulary: WF10x, WF16x (with pointer)
  • Cele: 4X, 10x, 40xS (spring), 100xS (oil, spring) DIN achromatic
  • Zakres powiększenia: 40X - 1600X
  • Stage: mechanicznetage with X-Y axis movement, stagzatrzymaj się
  • Konfiguracja oświetlenia: Transmitted (lower)
  • Skraplacz: Abbe, 1.25 NA
  • Membrana: Przysłona tęczówkowa
  • Źródło światła: Tungsten (incandescent), variable intensity
  • Rodzaj oświetlenia: Jasne pole
  • Moc: 110 V
  • Tworzywo: Metal, tungsten
  • Wymiary (wys. x szer. x gł.): 15 x 7.5 x 5.125 cale (w przybliżeniu)
  • Waga: 10 funta

10. Gwarancja i obsługa klienta

For warranty information, technical assistance, or to purchase replacement parts, please contact AmScope customer support. Refer to the AmScope website or your purchase documentation for current contact details.