VOLTCRAFT SL-451

Voltcraft SL-451 Digital Sound Level Meter User Manual

Modele: SL-451

Wstęp

The Voltcraft SL-451 is a digital sound level meter designed for precise noise measurement and data logging. This device complies with IEC 61672-1 Class 2 standards, making it suitable for various professional applications. It features a robust housing with injected rubber protection, ensuring durability in challenging environments. The integrated data logger can store up to 32,000 measurements, which can be transferred to a PC via a USB interface for detailed analysis using the included software. An extendable microphone cable allows for flexible measurement in hard-to-reach areas.

Instrukcje bezpieczeństwa

Please read these safety instructions carefully before operating the device to ensure safe and proper use.

  • Nie wystawiaj urządzenia na działanie ekstremalnych temperatur, bezpośredniego światła słonecznego i wysokiej wilgotności.
  • Avoid strong vibrations or mechanical shocks.
  • Do not open the device housing; refer servicing to qualified personnel.
  • Używaj wyłącznie wskazanego zasilacza i akcesoriów.
  • Przechowywać urządzenie w miejscu niedostępnym dla dzieci.
  • Ensure the microphone is clean and free from obstructions for accurate readings.

Zawartość opakowania

Sprawdź, czy po rozpakowaniu znajdują się wszystkie elementy:

  • Voltcraft SL-451 Digital Sound Level Meter
  • Microphone extension cable (3 meters)
  • Kabel USB
  • Płyta CD z oprogramowaniem na PC
  • Zasilacz
  • Etui transportowe
  • Instrukcja obsługi
Voltcraft SL-451 Sound Level Meter with carrying case, power adapter, and screwdriver
Image: The Voltcraft SL-451 sound level meter, its protective carrying case, power adapter, and a small screwdriver. This image illustrates the complete package contents.

Urządzenie ponadview

Familiarize yourself with the main components of the SL-451.

Przód view of the Voltcraft SL-451 Digital Sound Level Meter
Obraz: Zbliżenie view of the Voltcraft SL-451 digital sound level meter, showing its display, control buttons, and microphone with a foam windscreen. The device is shown with its integrated stand extended.
  • Mikrofon: For sound detection.
  • Wyświetlacz LCD: Shows measurement values, settings, and status indicators.
  • Przyciski sterujące: For power, mode selection, data hold, and other functions.
  • Port USB: For PC connection and data transfer.
  • Pobór mocy: Do zasilania zewnętrznego.
  • Komora baterii: For battery installation.

Organizować coś

1. Włączanie urządzenia

The SL-451 can be powered by batteries or an external power adapter.

Montaż baterii:

  1. Otwórz pokrywę komory baterii znajdującą się z tyłu urządzenia.
  2. Włóż wymagane baterie, zwracając uwagę na prawidłową biegunowość.
  3. Dokładnie zamknij pokrywę komory baterii.

Zasilanie zewnętrzne:

Connect the provided power adapter to the device's power input and then to a suitable power outlet.

2. Podłączenie mikrofonu

The device comes with a detachable microphone and an extension cable.

  • For direct use, ensure the microphone is securely attached to the main unit.
  • For remote measurements, connect the microphone to one end of the 3-meter extension cable and the other end of the cable to the device's microphone input.
  • Always use the foam windscreen on the microphone to minimize wind noise interference.

3. Software Installation (for Data Logging)

To utilize the data logging and analysis features, install the provided PC software.

  1. Włóż płytę CD z oprogramowaniem do napędu CD/DVD komputera.
  2. Aby zainstalować oprogramowanie, postępuj zgodnie z instrukcjami wyświetlanymi na ekranie.
  3. After installation, connect the SL-451 to your computer using the supplied USB cable.
  4. The software should automatically detect the device. If not, refer to the software's help documentation for troubleshooting connection issues.

Instrukcja obsługi

1. Pomiar podstawowy

  1. Naciśnij MOC przycisk, aby włączyć urządzenie.
  2. The display will show the current sound level in decibels (dB).
  3. Weighting (A/C): Użyj Klimatyzacja button to switch between A-weighting (for general noise measurement, mimicking human ear response) and C-weighting (for measuring peak sound pressure levels).
  4. Czas reakcji (SZYBKI/WOLNY): Użyj SZYBKO/WOLNO button to select the desired response time. Fast response is suitable for rapidly changing noise, while slow response is for more stable noise levels.
  5. Wybór zakresu: The device features an automatic range selection from 30 to 130 dB. Manual range adjustment may also be available depending on the model's specific firmware.
  6. Przytrzymanie MAX/MIN: Naciśnij MAKS./MIN. button to display the maximum or minimum sound level recorded during a measurement session. Press again to cycle through modes or exit.
  7. Przechowywanie danych: Naciśnij TRZYMAĆ Naciśnij przycisk, aby zamrozić aktualny odczyt na wyświetlaczu. Naciśnij ponownie, aby zwolnić.

2. Rejestrowanie danych

The SL-451 can record up to 32,000 measurements.

  1. Upewnij się, że urządzenie jest włączone.
  2. Naciśnij REK button to start data logging. The "REC" indicator will appear on the display.
  3. Naciśnij REK ponownie, aby zatrzymać rejestrację.
  4. To retrieve logged data, connect the device to a PC using the USB cable and open the installed software.
  5. Follow the software instructions to download, view, and analyze the recorded measurements. The software supports analysis according to standards like DIN 15905-5.

3. Kalibracja

For accurate measurements, periodic calibration is recommended. The device is calibratable.

  • Use a standard sound calibrator (e.g., Voltcraft SLC-100, if available) to perform calibration.
  • Refer to the specific instructions provided with your calibrator and the SL-451's detailed manual for the calibration procedure.
  • Incorrect calibration can lead to inaccurate readings.

Konserwacja

Czyszczenie:

  • Przetrzyj urządzenie miękką, suchą ściereczką.
  • Nie należy używać środków czyszczących o właściwościach ściernych ani rozpuszczalników.
  • Keep the microphone clean and free of dust or debris.

Składowanie:

  • Jeśli urządzenie nie będzie używane przez dłuższy czas, należy wyjąć baterie, aby zapobiec ich wyciekowi.
  • Store the device in its carrying case in a cool, dry place.

Wymiana baterii:

Wymień baterie, gdy na wyświetlaczu pojawi się wskaźnik niskiego poziomu naładowania baterii. Zapewni to ciągłą pracę urządzenia i dokładne odczyty.

Rozwiązywanie problemów

ProblemMożliwa przyczynaRozwiązanie
Urządzenie się nie włącza.Low or dead batteries; incorrect battery polarity; power adapter not connected.Replace batteries; check battery polarity; ensure power adapter is securely connected.
Niedokładne odczyty.Microphone obstructed; device not calibrated; incorrect weighting/response time.Clean microphone; perform calibration; check A/C weighting and FAST/SLOW settings.
Nie można połączyć się z komputerem.USB cable faulty; software not installed correctly; driver issues.Try a different USB cable; reinstall software; check device manager for driver conflicts.
Data logging not working.Memory full; REC button not pressed correctly.Download data to PC and clear device memory; ensure REC button is pressed until indicator appears.

Specyfikacje

Model:SL-451
Zakres pomiarowy:30 to 130 dB (A/C)
Dokładność:± 1.4 dB
Zakres częstotliwości:31.5 Hz do 8 kHz
Ważenie:A i C
Czas reakcji:Szybki / Wolny
Data Logger Capacity:Do 32,000 pomiarów
Interfejs:USB
Zgodność:IEC 61672-1 Klasa 2
Wymiary (dł. x szer. x wys.):5 x 7.6 x 27.8 cm (1.97 x 2.99 x 10.94 cala)
Waga:350 gramów (0.77 funta)
Tworzywo:Rubber (exterior protection)
Cechy szczególne:Bargraph, Calibratable, Battery/Power supply operation, Min/Max memory, Backlight, Analog output.

Gwarancja i wsparcie

Voltcraft products are designed for reliability and performance. This device comes with a standard warranty as per local regulations. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official Voltcraft webstrona.

Dostępność części zamiennych: Części zamienne są dostępne przez 1 rok od daty zakupu.

For technical support, troubleshooting assistance beyond this manual, or service inquiries, please contact Voltcraft customer service or your authorized dealer. Contact information can typically be found on the manufacturer's webmiejscu lub w opakowaniu produktu.

© 2024 VOLTCRAFT. Wszelkie prawa zastrzeżone.

Niniejsza instrukcja ma charakter wyłącznie informacyjny. Dane techniczne mogą ulec zmianie bez powiadomienia.