The Sicce Ultrazero Flat Sucking Pump is designed for efficient removal of water from various areas, including flooded cellars, garages, and other spaces where minimal residual water is desired. This submersible pump is capable of reducing water levels down to 2-3 mm.
Główne cechy:
- Capable of pumping water down to 2 mm residual level.
- Fully submersible design.
- Handles dirt particles up to 3 mm in size.
- Equipped with a 10-meter power cable.
- Features a practical carry handle for easy transport.

Rysunek 1: Koniecview of the Sicce Ultrazero Flat Sucking Pump.
2. Informacje dotyczące bezpieczeństwa
Read all safety warnings and instructions before operating the pump. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Przed przystąpieniem do czyszczenia, obsługi lub wykonywania jakichkolwiek czynności konserwacyjnych należy zawsze odłączyć pompę od zasilania.
- Upewnij się, że napięcie zasilaniatage matches the pump's specifications (230 V/50 Hz).
- Do not operate the pump with a damaged power cord or plug. If damaged, it must be replaced by the manufacturer, service agent, or similarly qualified persons to avoid a hazard.
- Do not use the pump to handle flammable or explosive liquids.
- Trzymać dzieci i osoby nieupoważnione z dala od obszaru roboczego.
- Aby zapobiec przegrzaniu, należy upewnić się, że pompa jest całkowicie zanurzona podczas pracy.
- Avoid running the pump dry for extended periods.
- This pump is designed for water only. Do not use it for other liquids without consulting the manufacturer.
3. Konfiguracja i instalacja
Follow these steps to properly set up your Ultrazero pump:
- Rozpakuj pompę: Ostrożnie wyjmij pompę i wszystkie akcesoria z opakowania. Sprawdź, czy nie ma uszkodzeń.
- Podłącz wąż spustowy:
The pump features a 26.44 mm (3/4") AG pressure connection. Attach a suitable discharge hose (e.g., 20 mm (3/4") hose connection) to this outlet. Ensure the connection is secure to prevent leaks.

Figure 2: Close-up of the pump's discharge outlet and integrated carry handle.
- Pozycja pompy: Place the pump directly on the surface from which water needs to be removed. Ensure the pump is stable and upright. The flat base allows for efficient water removal down to minimal levels.
- Route the Discharge Hose: Direct the discharge hose to a suitable drainage area, ensuring the water will not flow back into the area being drained.
- Podłączenie zasilania: Plug the 10-meter power cable into a grounded 230 V/50 Hz electrical outlet. Ensure the outlet is protected by a Ground Fault Circuit Interrupter (GFCI) for added safety, especially in wet environments.

Figure 3: The flat base of the pump designed for low residual water levels.
4. Instrukcja obsługi
The Ultrazero pump is designed for simple operation:
- Zanurz pompę: Ensure the pump is fully submerged in the water you wish to remove. The pump requires water to cool its motor and operate correctly.
- Rozpocznij pompowanie: Once submerged and connected to power, the pump will begin operating automatically. It does not feature a float switch, so manual monitoring is required for optimal use.
- Monitoruj poziom wody: The pump will continue to operate until the water level reaches its minimum suction capability of 2-3 mm.
- Zatrzymaj pompowanie: To stop the pump, disconnect it from the power supply. It is recommended to disconnect the pump once the desired water level is reached or if the pump starts to run dry.

Figure 4: The Ultrazero pump effectively draining water from a small pool.

Figure 5: The pump in action on a flooded floor, demonstrating its low-level suction capability.

Figure 6: Illustration of the pump's ability to reduce water levels to approximately 2 mm.
5. Konserwacja
Regularna konserwacja zapewnia długowieczność i optymalną wydajność pompy.
- Czyszczenie: After each use, especially when pumping dirty water, rinse the pump thoroughly with clean water. This helps prevent sediment buildup.
- Sprawdź pod kątem zanieczyszczeń: Periodically check the pump's intake area for any debris (e.g., leaves, small stones) that might obstruct water flow. Remove any blockages carefully after disconnecting power.
- Kontrola kabla: Regularly inspect the power cable for cuts, abrasions, or other damage. Do not use the pump if the cable is damaged.
- Składowanie: When not in use, store the pump in a clean, dry place, protected from frost.

Figure 7: The pump can also be used for transferring water for tasks like garden watering from a rain barrel.
6. Rozwiązywanie Problemów
If you encounter issues with your Ultrazero pump, refer to the following common problems and solutions:
| Problem | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| Pompa nie uruchamia się. | Brak zasilania. Uszkodzony kabel zasilający. Zadziałało zabezpieczenie przeciążeniowe silnika. | Sprawdź podłączenie zasilania i gniazdko. Inspect cable for damage; replace if necessary (by qualified personnel). Disconnect power, allow motor to cool, then reconnect. |
| Pompa pracuje, ale woda nie jest wypompowywana. | Intake blocked. Wąż wylotowy jest zagięty lub zablokowany. Airlock in pump. | Disconnect power, clear intake. Check and clear discharge hose. Briefly lift and lower the pump while submerged to release trapped air. |
| Reduced pumping performance. | Partial blockage. Impeller worn. | Disconnect power, clean pump intake and impeller area. Skontaktuj się z obsługą klienta w celu uzyskania pomocy. |
| Pompa nieoczekiwanie zatrzymuje się. | Overheating due to low water level or blockage. Usterka elektryczna. | Disconnect power, check water level and clear blockages. Allow to cool. Jeśli problem będzie się powtarzał, skontaktuj się z obsługą klienta. |
If the problem persists after attempting these solutions, please contact Sicce customer support.
7. Specyfikacje techniczne
Detailed specifications for the Sicce Ultrazero Flat Sucking Pump, Model 925607:
| Specyfikacja | Wartość |
|---|---|
| Marka | Sicce |
| Numer modelu | 925607 |
| Max. Delivery Rate (Flow Rate) | 3000l/godz. |
| Max. Wysokość dostawy | 3.1m |
| Power Consumption (P1) | 80 W |
| Objętość operacyjnatage | 220-240 V / 50 Hz |
| Conductor Length (Power Cable) | 10 m (three-core, indoor and outdoor use) |
| Przyłącze ciśnieniowe | 26.44 mm (3/4") AG |
| Średnica przyłącza węża | 20 mm (3/4") |
| Max. Solids Size | 3 mm |
| Pozostały poziom wody | Down to 2-3 mm |
| Wymiary produktu (w przybliżeniu) | 140 mm (Diameter) x 160 mm (Height) / 5.5" x 6.3" |
| Waga przedmiotu | 2.6 kg (5.72 funta) |
| Przełącznik pływakowy | NIE |
| Zabezpieczenie przed przeciążeniem | No (Internal thermal protection may exist, but no external reset) |
| Pochodzenie | Wyprodukowano we Włoszech |

Figure 8: Technical drawing illustrating the pump's dimensions and 3/4" GAS connection.
8. Gwarancja i wsparcie
For warranty information or technical support regarding your Sicce Ultrazero Flat Sucking Pump, please contact Sicce customer service. Keep your purchase receipt and model number (925607) handy when contacting support.
Producent: Ebara
Marka: Sicce
For further assistance, visit the official Sicce webodwiedź witrynę lub skontaktuj się z lokalnym dystrybutorem.