Tenergia 01009

Tenergy 9.6V NiMH/NiCd RC Battery Charger Instruction Manual

Model: 01009

Produkt ponadview

This manual provides instructions for the Tenergy 9.6V (8S) NiMH/NiCd RC Battery Charger, designed for use with RC hobbies. It features a 400mA AC plug and a standard Tamiya connector. This charger is specifically for 9.6V NiMH/NiCd battery packs and is not compatible with LiPo batteries or other voltage battery types.

Tenergy 9.6V NiMH/NiCd RC Battery Charger

Image: The Tenergy 9.6V NiMH/NiCd RC Battery Charger with its standard Tamiya connector.

Instrukcje bezpieczeństwa

  • Only use this charger with 9.6V (8S) NiMH or NiCd battery packs. Do not attempt to charge LiPo batteries or any other battery chemistry.
  • Ta ładowarka jest niekompatybilny with Spike the Dinosaur or similar toys requiring specific charging protocols.
  • Ensure the battery connector is a standard Tamiya type. Incompatible connectors may cause damage.
  • Nie pozostawiaj ładujących się akumulatorów bez nadzoru.
  • Trzymaj ładowarkę i akumulator z dala od materiałów łatwopalnych.
  • Nie wystawiaj ładowarki na działanie wilgoci i ekstremalnych temperatur.
  • Jeśli ładowarka lub akumulator wykazują oznaki uszkodzenia, należy natychmiast zaprzestać ich używania.

Organizować coś

Before first use, inspect the charger and battery for any visible damage. Ensure the battery pack is a 9.6V NiMH or NiCd type with a standard Tamiya connector.

  1. Locate a standard AC power outlet (100-240V).
  2. Plug the charger's AC plug into the power outlet. The LED indicator on the charger will illuminate.
  3. Connect the standard Tamiya connector from your 9.6V NiMH/NiCd battery pack to the charger's output connector. Ensure a secure connection.
Tenergy charger with standard Tamiya connector dimensions

Image: Diagram showing the dimensions of a standard Tamiya connector, emphasizing compatibility. This charger is only compatible with white standard Tamiya connectors, not mini Tamiya connectors.

Tenergy charger connected to a power strip and battery

Image: The Tenergy charger plugged into a power strip, ready to connect to a battery pack.

Instrukcja obsługi

Ładowanie baterii

Once the charger is plugged into an AC outlet and connected to a compatible 9.6V NiMH/NiCd battery pack, the charging process will begin automatically.

  • Wskaźnik LED: The charger features a simple LED indicator to show charging status.
  • Jednolity czerwony: Oznacza, że ​​bateria jest aktualnie ładowana.
  • Jednolity zielony: Wskazuje, że bateria jest w pełni naładowana.
Tenergy charger LED indicators for charging and full charge

Image: Close-up of the charger showing a red LED for charging and a green LED for fully charged status.

For a 2000mAh battery pack, the estimated charge time from empty is approximately 5-6 hours at a 400mA charging speed. Charging times may vary based on battery capacity and discharge level.

Tenergy charger connected to a 9.6V 2000mAh battery pack

Image: The Tenergy charger connected to a 9.6V 2000mAh NiMH battery pack, illustrating the charging process.

Tomtage Kompatybilność

This charger is designed for 9.6V (8S) NiMH and NiCd battery packs. Always verify your battery's voltage and chemistry before connecting to prevent damage.

Two 9.6V NiMH battery packs, illustrating voltagkompatybilność

Image: Two different styles of 9.6V (8S) NiMH battery packs, demonstrating the charger's voltage kompatybilność.

Konserwacja

  • Utrzymuj ładowarkę w czystości, bez kurzu i zanieczyszczeń. Do czyszczenia używaj suchej ściereczki.
  • Jeśli nie używasz ładowarki, przechowuj ją w chłodnym i suchym miejscu.
  • Avoid wrapping the cable too tightly around the charger to prevent wire damage.

Rozwiązywanie problemów

ProblemMożliwa przyczynaRozwiązanie
Dioda LED ładowarki nie świeci.No power from AC outlet; charger or cable damaged.Check AC outlet with another device. Inspect charger and cable for damage. If damaged, discontinue use.
Charger LED remains red after extended charging.Battery not fully charged; faulty battery; charger malfunction.Allow more time for charging. Test battery with another compatible charger if available. Contact support if issue persists.
Charger LED is green but battery is not fully charged.Charger malfunction; battery issue.Ensure battery is properly connected. If the issue persists, the charger may be faulty.
Charger gets excessively hot.Overload; internal fault.Immediately disconnect the charger and battery. Do not use if it overheats. Contact support.

Specyfikacje

  • Numer modelu: 01009
  • Wejście Voltage: 100-240V AC
  • Objętość wyjściatage: 12 wolty
  • Prąd ładowania: 400mA
  • Kompatybilne typy baterii: NiMH, NiCd
  • Kompatybilna pojemność bateriitage: 9.6V (8s)
  • Typ złącza: Standard Tamiya
  • Waga przedmiotu: 3.21 uncji (0.2 funta)
  • Wymiary opakowania: 3.82 x 1.5 x 1.1 cala
  • Orzecznictwo: Zgodny z CE

Gwarancja i wsparcie

This Tenergy charger includes a 12-miesięczna gwarancja from the date of purchase. For warranty claims, technical support, or any questions regarding the product, please contact Tenergy Corporation directly. Refer to the product packaging or the official Tenergy webna tej stronie znajdziesz najbardziej aktualne dane kontaktowe.

Filmy o produktach

Tenergy 9.6V Charger Overview

Video: An official product video from Tenergy Corporation demonstrating the features and use of the 9.6V charger for RC hobbies. This video highlights voltage compatibility and ease of use.

Ask a question about this manual