The Renkforce 751560 Dual Motion Sensor is a passive infrared (PIR) detector designed for reliable motion detection in various environments. It features a dual sensor for enhanced accuracy and reduced false alarms, making it suitable for security and surveillance applications in private, commercial, and industrial settings. The sensor offers selectable Normally Open (NO) and Normally Closed (NC) operation, allowing integration with different alarm systems or for controlling lighting, such as staircase lights. It also includes an anti-tamper mechanism for added security.

Przód view of the Renkforce 751560 Dual Motion Sensor

Rysunek 1: Przód view of the Renkforce 751560 Dual Motion Sensor. This image shows the white rectangular housing with the curved detection lens at the top and the Renkforce logo at the bottom.

2. Instrukcje bezpieczeństwa

  • Przed instalacją i obsługą przeczytaj dokładnie niniejszą instrukcję.
  • Instalację i okablowanie powinien wykonywać wyłącznie wykwalifikowany personel.
  • Przed przystąpieniem do prac instalacyjnych lub konserwacyjnych należy upewnić się, że zasilanie jest odłączone.
  • Nie wystawiaj urządzenia na działanie ekstremalnych temperatur, wilgoci ani bezpośredniego światła słonecznego.
  • Avoid mounting the sensor near heat sources or objects that may cause rapid temperature changes, as this can lead to false alarms.
  • Do not paint or cover the sensor lens, as this will impair its functionality.
  • Urządzenie jest przeznaczone wyłącznie do użytku wewnątrz pomieszczeń.

3. Konfiguracja i instalacja

3.1. Zawartość opakowania

  • Renkforce 751560 Motion Detector
  • Materiały montażowe (śruby, kołki rozporowe)
  • Instrukcja obsługi

3.2. Miejsce montażu

Choose a suitable location for the motion sensor, typically in a corner or on a wall, where it can cover the desired detection area without obstruction. Avoid aiming the sensor directly at windows, heating vents, or areas with significant air currents.

Strona view of the Renkforce 751560 Dual Motion Sensor with mounting bracket

Rysunek 2: Strona view of the sensor showing the detachable wall mounting bracket. This bracket allows for easy installation and adjustment.

3.3. Kroki instalacji

  1. Przygotuj powierzchnię montażową: Mark the drilling points for the mounting bracket on the wall.
  2. Wiercenie otworów: Drill holes at the marked positions and insert the wall plugs (if necessary).
  3. Zamontuj wspornik montażowy: Przymocuj uchwyt montażowy do ściany za pomocą dołączonych śrub.
  4. Podłącz okablowanie: Open the sensor housing carefully. Connect the power supply (12V DC) and alarm output wires to the designated terminals inside the sensor. Ensure correct polarity.
  5. Set NO/NC Mode: Configure the sensor's output mode (Normally Open or Normally Closed) according to your alarm system's requirements using the internal jumper or switch.
  6. Attach Sensor to Bracket: Mount the sensor unit onto the attached bracket. Ensure it clicks securely into place.
  7. Adjust Detection Angle: Dostosuj kąt czujnika tak, aby obejmował pożądany obszar detekcji.
Detail of the Renkforce 751560 Dual Motion Sensor mounting bracket

Rysunek 3: Szczegółowy view of the mounting bracket, showing the screw holes and the swivel mechanism for angle adjustment.

4. Instrukcja obsługi

4.1. Włączanie

Once installed and wired, apply 12V DC power to the sensor. The sensor will typically undergo a brief initialization period (e.g., 30-60 seconds) during which its LED indicator may flash. Avoid movement in the detection area during this time.

4.2. Detection and Alarm Output

The dual PIR sensor detects infrared radiation changes caused by moving objects within its 12-meter range. Upon detection, the sensor's alarm output will change state (either open or closed, depending on your NO/NC setting) to trigger the connected alarm system or device.

4.3. Anty-Tampe Funkcja

The sensor is equipped with an anti-tamper switch. If the sensor's housing is opened or forcibly removed from its mounting bracket while powered, this switch will activate, triggering a separate tamper alarm output to your connected system.

5. Konserwacja

  • Czyszczenie: Periodically wipe the sensor lens and housing with a soft, dry cloth to remove dust and dirt. Do not use abrasive cleaners or solvents.
  • Testowanie: Regularly test the sensor's functionality by walking through its detection area to ensure it triggers the connected alarm system.
  • Kontrola: Visually inspect the wiring and mounting for any signs of damage or loosening.

6. Rozwiązywanie Problemów

ProblemMożliwa przyczynaRozwiązanie
Czujnik nie wykrywa ruchu.
  • Brak zasilania.
  • Nieprawidłowe okablowanie.
  • Soczewka czujnika jest zasłonięta lub brudna.
  • Sensor aimed incorrectly.
  • Check 12V DC power connection.
  • Verify wiring connections and polarity.
  • Wyczyść soczewkę czujnika.
  • Adjust sensor angle to cover the desired area.
Fałszywe alarmy.
  • Sensor mounted near heat sources (e.g., radiators, direct sunlight).
  • Air currents (e.g., from vents, open windows).
  • Small animals in detection area.
  • Relocate the sensor away from heat sources.
  • Zapewnij stabilne warunki środowiskowe.
  • Adjust sensitivity (if available, check manual for specific model features) or reposition to exclude pets.
Tamper alarm triggers unexpectedly.
  • Sensor housing not securely closed.
  • Sensor not securely attached to mounting bracket.
  • Faulty tamper przełącznik.
  • Ensure the housing is properly closed.
  • Re-attach the sensor firmly to its bracket.
  • Contact support if the issue persists after checking physical connections.

7. Specyfikacje techniczne

Marka:Renkforce
Numer modelu:751560
Technologia wykrywania:Dual PIR (Passive Infrared)
Zasilanie:12V prądu stałego
Maksymalny zasięg:12 metrów
Typ montażu:Ściana
Typ wyjścia:Selectable NO (Normally Open) / NC (Normally Closed)
Anty-Tampeee:Tak
Zgodne urządzenia:Alarm systems
Zalecane użycie:Security and surveillance
Wymiary (wys. x szer. x gł.):Approx. 150 x 90 x 50 mm (based on image)
Wymagana bateria:NIE
Renkforce 751560 Dual Motion Sensor with dimensions indicated

Rysunek 4: Przód view of the sensor with approximate dimensions: 15cm height, 9cm width, and 5cm depth.

8. Informacje o gwarancji

According to the product specifications, there is no warranty specified for this product. Please refer to your point of purchase for any return or defect policies.

EU spare parts availability is stated as 1 year.

9. Wsparcie i kontakt

For technical support or further inquiries, please contact your retailer or the Renkforce customer service department. Refer to the contact information provided with your purchase documentation.

You can also visit the official Renkforce store for more information: Renkforce Store

Renkforce 751560 Dual Motion Sensor Instruction Manual. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.