Intermatic EI200LA Electronic In-Wall Countdown Auto-Off Timer User Manual

Model: EI200LA

Wstęp

The Intermatic EI200LA Electronic In-Wall Countdown Auto-Off Timer is designed to replace standard toggle-style wall switches, providing silent electronic timing operation. This timer offers time ranges of 5, 10, 15, and 30 minutes, making it suitable for various applications such as indoor/outdoor lighting, exhaust fans, and other electrical loads. This manual provides essential information for safe installation, operation, and maintenance of your timer.

Cechy

  • Provides 5/10/15/30 Minute time ranges.
  • Available in Light Almond finish.
  • Offers silent operation.
  • Replaces single-pole switches in a variety of applications.
  • CFL compatible with all EI200 series timers (EI210W, EI220W, etc.), EI500C, EI500WC, EI500LAC, EI600C and EI600LAC.
  • Designed for use with a decorator-style wall plate (NOT included).

Parametry elektryczne

  • 120 V AC, 60 Hz
  • 15A General Purpose
  • 1000W wolfram
  • Silnik 1/4 KM
  • Statecznik 1000 VA

Instrukcje instalacji

OSTRZEŻENIE: Aby uniknąć pożaru, porażenia prądem lub śmierci, przed podłączeniem przewodów należy wyłączyć zasilanie na wyłączniku obwodu i sprawdzić, czy zasilanie jest wyłączone.

Lead Wire Identification:

  • Czarny: Linia/gorące
  • Biały: Neutralny
  • Czerwony: Obciążenie
  • Zielony: Grunt
  1. Remove wall plate and disconnect light switch. Make sure both "hot" and neutral wires are present in the junction box. (See Fig. 1). If both wires are not present, additional wiring may be necessary before installation can be completed.
  2. Connect red timer wire to wire from fixture using wire connector. Connect black timer wire to the "hot" (usually black or red) wire in junction box using wire connector. Cut white wire in junction box (or green splice) and strip 3/8" of insulation on both wires. Connect white timer wire to white wire in junction box using wire connector. (See Fig. 2).
  3. If the wall switch you are replacing had separate grounding conductors connected to the GREEN screw on the switch, make sure to connect these to the green wire from the timer with a wire connector.
  4. Sprawdź, czy wszystkie połączenia przewodów są bezpieczne.
  5. Place all wires inside junction box. Fit timer into junction box. Next, install timer using (2) mounting screws furnished.
  6. Reconnect your electrical power.
Wiring diagram for Intermatic EI200LA timer, showing connections for hot, neutral, load, and ground wires.

Figure 1 & 2: Wiring diagrams for the EI200LA timer. Figure 1 illustrates the timer's internal connections, while Figure 2 shows the typical wiring setup within a wall box, connecting the timer to the fixture and power supply.

Działanie

Tryb timera

To enter Timer mode, press and release the push button (for less than 2 seconds) repeatedly to select one of the four time settings: OFF (5 minutes - 10 minutes - 15 minutes - 30 minutes) - OFF. The illuminated LED indicates which time setting is selected and the connected load is turned ON. Timer starts counting down until time out is reached, all 5 LED's go off and the connected load turns OFF.

Tryb wstrzymania (praca ciągła)

To turn timer ON for extended periods of time, press and hold the push button for more than 2 seconds. Timer enters HOLD mode, HOLD LED turns on, and the connected load is turned ON. To exit HOLD mode press and release the push button, all 5 LED's go off and the connected load turns OFF.

Intermatic EI200LA timer face with 5, 10, 15, 30 minute and HOLD options.

Image of the Intermatic EI200LA timer face, showing the push button and LED indicators for 5, 10, 15, 30 minutes, and HOLD mode.

Konserwacja

The Intermatic EI200LA timer is designed for maintenance-free operation. To ensure longevity and proper function, keep the device clean and free from dust. Do not use abrasive cleaners or solvents. If the device requires cleaning, gently wipe the surface with a soft, damp cloth. Ensure power is disconnected at the circuit breaker before any cleaning or inspection.

Rozwiązywanie problemów

  • Timer nie odpowiada: Ensure power is supplied to the circuit. Check the circuit breaker. Verify all wiring connections are secure according to the installation instructions.
  • Load not turning ON/OFF: Confirm the timer is correctly wired to the load. Check the selected time setting or if the timer is in HOLD mode.
  • Praca przerywana: Inspect wiring for loose connections. Ensure the timer is not overloaded beyond its specified electrical ratings.

If issues persist after following these steps, contact a qualified electrician or Intermatic customer support for assistance.

Specyfikacje

Numer modeluEI200LA
MarkaIntermatyczny
KolorLekki Migdał
Zakresy czasu5, 10, 15, 30 Minutes
Tomtage120 V AC, 60 Hz
General Purpose Rating15A
Tungsten Rating1000 W
Ocena silnika1 / 4 HP
Ballast Rating1000 VA
Wymiary produktu2.9 x 2.1 x 4.6 cala
Waga przedmiotu4.8 uncji
UPC007827510057, 078275100572

Informacje o gwarancji

This Intermatic product is covered by a 1-letnia gwarancja. This warranty covers replacement of the unit but does not include labor costs. For detailed warranty terms and conditions, please refer to the official Intermatic warranty statement or contact customer support.

Obsługa klienta

For technical assistance, troubleshooting, or warranty claims, please contact Intermatic customer support. You can find contact information on the official Intermatic webstronie internetowej lub odnosząc się do opakowania produktu.

© 2023 Intermatic. All rights reserved. Information in this manual is subject to change without notice.