Empire VFSR24LP

Empire Vent-Free Slope Glaze Burner VFSR24LP Instruction Manual

Model: VFSR24LP

1. Wprowadzenie

This manual provides essential information for the safe installation, operation, and maintenance of your Empire Vent-Free Slope Glaze Burner, Model VFSR24LP. This 24-inch propane burner features a Millivolt Safety Valve with an on/off switch and is designed for use with Empire "LS" log sets of the same size. It incorporates internal ceramic beads to enhance flame appearance and can produce up to 38,000 BTU.

2. Ważne informacje dotyczące bezpieczeństwa

Read this entire manual carefully before installation and use of this vent-free gas burner. Failure to follow these instructions could result in property damage, personal injury, or loss of life.

  • Profesjonalna instalacja: Instalację i serwisowanie musi wykonywać wykwalifikowany instalator, firma serwisowa lub dostawca gazu.
  • Vent-Free Appliance: Jest to urządzenie bezodpływowe. Pobiera powietrze do spalania z pomieszczenia, w którym jest zainstalowane. Należy zapewnić odpowiednią wentylację.
  • Typ paliwa: This burner is designed for use with Propane (LP) gas only. Do not use any other fuel.
  • Odprawy: Maintain proper clearances to combustibles as specified in the installation instructions.
  • Tlenek węgla: Vent-free gas products produce carbon monoxide. Ensure proper room size and ventilation. Install a carbon monoxide detector in your home.
  • Gorące powierzchnie: The burner and surrounding surfaces will become hot during operation. Keep children, pets, and clothing away.

3. Konfiguracja i instalacja

3.1 Fireplace Requirements

Ensure your fireplace meets the minimum dimensions required for the 24-inch burner and associated log set. Refer to the diagram and table below for guidance.

Fireplace Dimensions Diagram and Table

Opis obrazu: A diagram illustrating fireplace dimensions (front width opening, rear width, depth, and height) with a table below it. The table provides non-Empire minimum firebox dimensions for various Slope Glaze Burner models, including log length, BTU input, front width, rear width, depth, height, and shipping weight. For the VFSR-24 model, it specifies a 24-inch log length, 36,000 BTU input, 34-inch front width, 27-inch rear width, 14-inch depth, and 18-inch height.

3.2 Fuel Type Connection

This burner operates on Propane (LP) gas. Ensure your gas supply is correctly connected by a qualified professional.

Propane Gas Symbol

Opis obrazu: A circular grey icon with a white silhouette of a propane tank and the word "PROPANE" in white text below it, indicating the required fuel type.

3.3 Millivolt Wiring

The burner features a Millivolt Safety Valve. Refer to the wiring diagram for proper electrical connections, especially if installing an optional thermostat or remote control receiver.

Millivolt Wiring Diagram

Opis obrazu: A detailed wiring diagram titled "MILLIVOLT WIRING". It shows connections for a gas valve, thermopile, thermocouple, and optional components like a thermostat, wall switch, and remote control receiver. Wires are color-coded (red, green, black) and labeled with their functions. A note indicates that any original wire supplied with the unit must be replaced with number 18, 150°C wire or its equivalent if damaged.

3.4 Log Set Placement

This burner requires an Empire "LS" log set of the same size (24-inch) for optimal performance and appearance. Follow the log set manufacturer's instructions for proper placement on the burner.

4. Instrukcja obsługi

4.1 Pilot Ignition (Standing Pilot/Piezo)

  1. Ensure the gas supply to the unit is open.
  2. Locate the control knob on the Millivolt Safety Valve.
  3. Push the control knob in and turn it to the "PILOT" position.
  4. While holding the knob in, repeatedly press the piezo igniter button until the pilot flame ignites.
  5. Continue to hold the control knob in for approximately 30-60 seconds after the pilot ignites to allow the thermocouple to heat up. Release the knob; the pilot should remain lit. If it extinguishes, repeat steps 3-5.

4.2 Obsługa palnika

  1. Once the pilot is lit, turn the control knob from "PILOT" to the "ON" position.
  2. Use the integrated on/off switch on the Millivolt Safety Valve to turn the main burner on or off.
  3. If a remote control or wall switch is installed, use that device to control the main burner.

4.3 Wyłączanie palnika

  1. Turn the main burner off using the on/off switch or remote control.
  2. To turn off the pilot, turn the control knob to the "OFF" position.
  3. For extended periods of non-use, turn off the main gas supply to the appliance.

5. Konserwacja

Regular maintenance ensures safe and efficient operation of your burner.

  • Roczna inspekcja: Have the burner and gas connections inspected annually by a qualified service technician.
  • Czyszczenie: Keep the burner and log set free of dust and debris. Use a soft brush or vacuum cleaner. Do not use abrasive cleaners.
  • Pilot and Burner Ports: Periodically check pilot and burner ports for obstructions. Clean gently if necessary.
  • Zestaw logów: Inspect the log set for cracks or damage. Replace any damaged logs.

6. Rozwiązywanie Problemów

If you experience issues, consult this section before calling for service.

ProblemMożliwa przyczynaRozwiązanie
Pilot się nie zapaliBrak dopływu gazu
Pilot orifice clogged
Zapalnik nie iskrzy
Sprawdź zawór gazowy
Wyczyść otwór pilotażowy
Check igniter electrode gap
Pilot lights but will not stay litThermocouple not heating
Luźne połączenie termopary
Hold pilot knob longer
Tighten thermocouple connection
Główny palnik nie zapala sięPilot not lit
Control knob not in "ON" position
On/off switch off
Lekki pilot
Turn control knob to "ON"
Włącz przełącznik
Burner produces yellow flame/sootZatkane otwory palnika
Nieprawidłowe ciśnienie gazu
Wyczyść porty palnika
Skontaktuj się z wykwalifikowanym technikiem

7. Specyfikacje

FunkcjaSzczegół
ModelVFSR24LP
MarkaImperium
Rozmiar palnika24-calowy
Typ paliwaPropan (LP)
BTU Input (Max)38,000 BTU
Typ zaworuMillivolt with On/Off Switch
Pilot TypeStanding Pilot/Piezo Ignition
Log Set RequirementEmpire "LS" log sets of the same size
TworzywoCeramic (internal beads)
Wymiary produktu28.5" gł. x 16.75" szer. x 9" wys.