PILZ 777314

Pilz PNOZ X3P Safety Relay Instruction Manual

Model: 777314 | Brand: PILZ

1. Wprowadzenie

This manual provides essential information for the safe installation, operation, and maintenance of the Pilz PNOZ X3P Safety Relay, model 777314. The PNOZ X3P is designed for monitoring E-STOP pushbuttons, safety gates, and light grids in industrial applications, ensuring personnel and machine safety.

2. Instrukcje bezpieczeństwa

OSTRZEŻENIE: Failure to follow these safety instructions can result in serious injury or death, and damage to equipment.

  • Only qualified personnel familiar with industrial safety standards and electrical systems should install, operate, or maintain this device.
  • Disconnect all power before performing any installation, wiring, or maintenance tasks.
  • Upewnij się, że całe okablowanie jest zgodne z lokalnymi i krajowymi przepisami elektrycznymi.
  • Do not bypass or disable safety functions.
  • Regularly inspect the device and associated safety components for damage or malfunction.
  • Use only genuine PILZ replacement parts.

3. Koniec produktuview

The Pilz PNOZ X3P (Model 777314) is a safety relay designed for monitoring safety functions. It features:

  • Funkcjonować: E-STOP, safety gate, light grid monitoring.
  • Konfiguracja kontaktu: 3 Normally Open (NO) safety contacts, 1 Normally Closed (NC) auxiliary contact, 1 Semiconductor Output (SO).
  • Objętość dostawtage Zakres: 24-240VAC/DC (Coil Voltage: 24V AC/DC).
  • Tryb działania: Automatyczne resetowanie.
  • Szerokość: 45 mm.
Pilz PNOZ X3P Safety Relay, front view with terminals and indicators

Rycina 1: Przód view of the Pilz PNOZ X3P Safety Relay, showing terminals and indicators.

4. Konfiguracja i instalacja

4.1 Montaż

Mount the PNOZ X3P on a 35mm DIN rail in a control cabinet. Ensure adequate ventilation around the device to prevent overheating. Maintain proper clearance from heat-generating components.

4.2 Połączenia elektryczne

Before making any electrical connections, ensure the main power supply is disconnected and locked out. Refer to the wiring diagrams for correct terminal assignments.

5. Okablowanie

The PNOZ X3P supports 1-channel or 2-channel wiring for safety inputs. The choice depends on the required safety integrity level (SIL) and performance level (PL).

5.1 Input Wiring (E-STOP, Safety Gate, Light Grid)

  • 1-Channel Wiring: Connect the safety device (e.g., E-STOP) to a single input channel. This configuration offers basic safety.
  • 2-Channel Wiring: Connect the safety device to two independent input channels. This configuration provides redundancy and higher fault tolerance, suitable for higher safety requirements.

5.2 Output Wiring

The relay provides 3 NO safety contacts for controlling power to hazardous machinery and 1 NC auxiliary contact for signaling purposes. The 1 SO (semiconductor output) can be used for diagnostic feedback to a PLC.

Ensure that the load connected to the safety contacts does not exceed the maximum switching current of 15 Amps and maximum switching voltage 240 woltów.

Rysunek 2: Example wiring diagram for a 2-channel E-STOP application. (Actual diagram not provided, refer to product documentation for specific wiring.)

6. Instrukcja obsługi

The PNOZ X3P operates in an automatic reset mode. Once the safety input circuit is closed (e.g., E-STOP released, safety gate closed), the safety relay will automatically energize its output contacts, provided no faults are detected.

6.1 Zasilanie

Upon applying power, the relay performs an internal self-test. If the safety inputs are closed and no faults are present, the output contacts will close, and the status indicators will illuminate.

6.2 Safety Function Activation

When a safety input is opened (e.g., E-STOP pressed, safety gate opened), the PNOZ X3P immediately de-energizes its safety output contacts, bringing the monitored machine to a safe state.

6.3 Resetowanie

Due to its automatic reset function, the relay will re-energize its outputs as soon as the safety input circuit is restored and no faults are present. Ensure that the machine can only restart safely after a reset.

7. Konserwacja

Regular maintenance is crucial to ensure the continued safe operation of the PNOZ X3P safety relay.

  • Przeglądy okresowe: Visually inspect the device and its wiring for any signs of damage, loose connections, or contamination.
  • Test funkcjonalny: Periodically test the entire safety circuit, including the PNOZ X3P, by activating the connected safety devices (E-STOP, safety gate, light grid) to verify their proper function.
  • Czyszczenie: Keep the device free from dust and debris. Use a dry, soft cloth for cleaning. Do not use abrasive cleaners or solvents.

8. Rozwiązywanie Problemów

If the safety relay does not function as expected, consider the following common issues:

ProblemMożliwa przyczynaRozwiązanie
Outputs do not energize after power-up.
  • Brak zasilania.
  • Safety inputs open (e.g., E-STOP pressed).
  • Błąd wewnętrzny.
  • Sprawdź połączenia zasilania i głośnośćtage.
  • Ensure all safety inputs are closed.
  • Contact PILZ technical support.
Outputs de-energize unexpectedly.
  • Safety input opened momentarily.
  • Luźne okablowanie.
  • Ingerencja.
  • Check safety devices for intermittent operation.
  • Sprawdź wszystkie połączenia okablowania.
  • Zapewnij odpowiednie uziemienie i ekranowanie.

If troubleshooting steps do not resolve the issue, contact PILZ technical support.

9. Specyfikacje techniczne

ParametrWartość
Model777314
MarkaMUSHROOM
Tryb działaniaAutomatyczny
Objętość cewkitage24 V (prąd przemienny/stały)
Kontakt Aktualna ocena6 Amps
Maksymalny prąd przełączania15 Amps
Maksymalna objętość przełączaniatage240 wolty
Waga przedmiotu0.64 funtów

10. Gwarancja i wsparcie

PILZ products are manufactured to high-quality standards and come with a manufacturer's warranty. For specific warranty terms and conditions, please refer to the official PILZ webodwiedź witrynę lub skontaktuj się z lokalnym dystrybutorem.

For technical assistance, product support, or to report a malfunction, please contact PILZ customer service. Have your product model (777314) and serial number ready when contacting support.

PILZ Official Webstrona: www.pilz.com

© 2024 PILZ. All rights reserved. Information subject to change without notice.

Powiązane dokumenty - 777314

Przedview myPNOZ: Signal Forwarding to Another myPNOZ - Application Note
This application note from Pilz details how to configure and utilize the myPNOZ modular safety relay for signal forwarding between multiple myPNOZ units. It covers essential aspects such as safety functions, zone separation, hardware configuration, and adherence to functional safety standards like EN ISO 13849-1 and EN 62061. The document provides practical guidance for implementing safe automation solutions.
Przedview Instrukcja obsługi przekaźnika bezpieczeństwa Pilz PNOZ X6
Kompleksowa instrukcja obsługi przekaźnika bezpieczeństwa Pilz PNOZ X6, obejmująca jego funkcje, instalację, okablowanie, obsługę i specyfikację techniczną. Zawiera wytyczne dotyczące bezpieczeństwa i informacje dotyczące zamówień.
Przedview Przekaźnik bezpieczeństwa Pilz PNOZ s4 – instrukcja obsługi i dane techniczne
Kompleksowy przewodnik po przekaźniku bezpieczeństwa Pilz PNOZ s4, obejmujący jego funkcje, instalację, okablowanie, obsługę i specyfikacje techniczne zapewniające bezpieczeństwo maszyn.
Przedview Instrukcja obsługi przekaźnika bezpieczeństwa Pilz PNOZ X7
Kompleksowa instrukcja obsługi przekaźnika bezpieczeństwa Pilz PNOZ X7, szczegółowo opisująca jego funkcje, instalację, obsługę, specyfikacje bezpieczeństwa i dane techniczne dotyczące zastosowań automatyki przemysłowej.
Przedview Pilz PNOZmulti 2 Kommunikationsschnittstellen Bedienungsanleitung
Diese Bedienungsanleitung beschreibt die Kommunikationsmöglichkeiten und Schnittstellen für das konfigurierbare Kleinsteuerungssystem Pilz PNOZmulti 2, einschließlich Feldbus- und Ethernet-Kommunikation.
Przedview PNOZmulti 2 Technical Catalogue: Configurable Safe Small Controllers
Explore the PNOZmulti 2 Technical Catalogue from Pilz, detailing configurable safe small controllers designed for industrial safety. Discover base units, expansion modules, software tools, and comprehensive technical specifications for advanced machine safety solutions.

Ask a question about this manual